Skip to content

Detection and Volumetry of Pulmonary Nodules on Ultra-low Dose Chest CT Scan With Deeplearning Image Reconstruction Algorithm (DLIR)

Detection and Volumetry of Pulmonary Nodules on Ultra-low Dose Chest CT Scan With Deeplearning Image Reconstruction Algorithm (DLIR)

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04482114
Acronym
DLIRTHORAX
Enrollment
70
Registered
2020-07-22
Start date
2020-07-22
Completion date
2022-03-04
Last updated
2026-06-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pulmonary Nodules, Multiple

Keywords

lung nodules, pulmonary nodules, lung cancer, radiation dose, dose reduction, low dose CT, ultra-low dose CT, DLIR, deep learning reconstruction

Brief summary

evaluate the diagnostic performance of ultra-low dose CT using deep learning-based reconstruction in the detection of pulmonary nodules.

Detailed description

* Background: Lung cancer is the leading cause of cancer deaths. Patients with pulmonary nodules often undergo multiple computed tomography (CT) examinations for diagnostic and follow-up purposes. * Purpose: The main objective of this study is to evaluate the diagnostic performance of ultra-low dose CT using deep learning-based reconstruction in the detection of pulmonary nodules. * Abstract: Despite recent advances, lung cancer remains the most commonly diagnosed cancer and the leading cause of cancer death worldwide because it is often diagnosed at advanced stages that are not surgically curable. Nevertheless, early detection of lung cancer allows surgical resection, offers curative treatment and the best chance of survival. There is currently no screening program in France, but individual screening can be carried out depending on risk factors. Many pulmonary nodules are discovered each year, most of which are benign. The challenge is to distinguish malignant lesions from the multitude of benign lesions. One of the most effective criteria is the doubling time of the nodules which leads to multiple follow-up examinations requiring ionizing radiation to assess the size and growth of the nodules. Great efforts are currently being made by CT manufacturers in order to reduce the radiation with equivalent diagnostic performance. Patients who were referred to our department for an unenhanced low-dose chest CT (LD CT) for pulmonary nodules check-up or follow-up, and had consented to participate in the study, will undergo an additional ultra-low dose acquisition (ULDCT, \<0,25 mSv, similar to standard two-view chest X-Ray) with deep learning-based reconstruction (DLIR). The main objective of this study is to evaluate the diagnostic performance between ULD and LD CT protocols for the detection of pulmonary nodules. The impact of dose reduction will be assessed in this context. The data from each examination will be blindly interpreted from the results of the other one. No follow-up will be required for the study.

Interventions

RADIATIONULD CT

All the examinations are part of the routine care. Addition of the ULD CT protocol does not require injection of contrast agent and does not extend the duration of the examination.

Sponsors

Centre Hospitalier Universitaire, Amiens
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

prospective transversal monocentric study

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Age ≥ 18 years old, * Patient referred for non-enhanced chest CT for lung nodule check-up or follow-up, * Affiliation to a social security program, * Ability of the subject to understand and express opposition

Exclusion criteria

* Age \<18 years old, * Person under guardianship or curatorship, * Pregnant woman, * Any contraindications to CT

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic accuracyDay 0The study aimed to investigate the diagnostic accuracy (Sensibility and Specificity) of ultra-low dose CT using DLIR reconstruction for the detection of pulmonary nodules in comparison with the low dose CT reference protocol.

Secondary

MeasureTime frameDescription
Image qualityDay 0* The signal-to-noise ratio or SNR is calculated on areas of interest placed manually on the image (pulmonary parenchyma, axillary fat and surrounding air). * This ratio is calculated by the average signal strength in these areas, divided by the standard deviation of the signal in outdoor areas such as the surrounding air. * The quality of the image is estimated by a score ranging from 0 (poor quality) to 3 (excellent quality) determined subjectively by the operator.
Pulmonary nodules volumeDay 0Difference of pulmonary nodules volume between images acquired at low dose CT and ultra-low dose CT.

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 12, 2026