Skip to content

EBUS Guided Cryobiopsies With Ultrathin Cryoprobe in Patients With Peripheral Pulmonary Nodules - a Feasibility Study

EBUS Guided Cryobiopsies With Ultrathin Cryoprobe in Patients With Peripheral Pulmonary Nodules - a Feasibility Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04471324
Enrollment
34
Registered
2020-07-15
Start date
2020-03-31
Completion date
2020-08-31
Last updated
2020-10-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Transbronchial Cryobiopsy

Brief summary

The standard procedure in the diagnosis of peripheral round foci is bronchoscopy with transbronchial forceps biopsy (TBB). Despite the simultaneous application of X-ray fluoroscopy, the diagnostic value of this method depends strongly on the size, location and relationship of the foci to the airways as well as their radiological representability. By inserting radial 20 MHz ultrasound probes through the working channel of a flexible bronchoscope into the periphery of the lung, the detection of peripheral foci can be improved. By simultaneously using a virtual bronchoscopy with an ultra-thin bronchoscope, even smaller round foci in the periphery of the lung can be detected. For some years now, tension-resistant cryoprobes have been used for transbronchial biopsy. Here, especially in lesions that can only be reached endoscopically tangentially, advantages have been shown over forceps biopsy. Much larger tissue samples can be obtained without increasing the complication rate. Studies showed that the combination of the EBUS navigation technique with the cryobiopsy procedure is feasible and safe in the endoscopic diagnosis of peripheral lung tumors. This study investigates to what extent the combination of an ultra-thin cryoprobe with an ultra-thin bronchoscope together with the radial EBUS can further improve the diagnosis. This study is a non-randomized pilot study to prove the feasibility of this procedure. The EBUS probe and the bronchoscope are CE certified for this application. The study will be conducted as a monocentric study at the Thorax Clinic at Heidelberg University Hospital. A total of 30 patients with an indication for transbronchial biopsy will be prospectively included. All patients will be examined according to the clinical standard. After a freezing time of 3-7 seconds, the probe together with the bronchoscope will be extracted and the sample will be defrosted in a water-filled sample vial. Up to 4 biopsies will be taken depending on the investigator's assessment. The samples will be collected separately and the order of the biopsies will be recorded. The primary endpoint is the feasibility of the procedure. Secondary endpoints are safety, diagnostic hit rate, biopsy size and quality and success rate depending on the position of the EBUS probe (tangential or central).

Interventions

DEVICEEBUS cryo probe

patients receive a transbronchial cryo biopsy with the EBUS cryo probe from ERBE and an ultra thin bronchoskope

Sponsors

Erbe Elektromedizin GmbH
CollaboratorINDUSTRY
Thoraxklinik-Heidelberg gGmbH
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Single or multiple peripheral pulmonary round foci in CT * signed patient information

Exclusion criteria

* severe co-mornidity * no signed patien information * contraindication for intervention

Design outcomes

Primary

MeasureTime frameDescription
Feasibility of the procedure - assessed by diagnosis agreement within the multidisciplinary team discussionDay 1Pathological assessment of biopsies for ILD diagnosis

Secondary

MeasureTime frameDescription
Bleeding time in secondsDay 1 until Day 2Assessed by using a stop watch and entering data into a questionnaire
Size of biopsiesDay 1Planimetry
Quality of biopsiesDay 1artefact-free biopsies
Exacerbation rate4 weeks after biopsyAssessment of exacerbations until 4 weeks after biopsy