Skip to content

Functional Follow-up After Endoscopic Calcaneoplasty for Haglund's Deformity

Functional Follow-up After Endoscopic Calcaneoplasty for Haglund's Deformity

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04471259
Enrollment
42
Registered
2020-07-15
Start date
2012-01-22
Completion date
2020-03-21
Last updated
2020-07-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Haglund's Deformity

Keywords

Haglund's Deformity, Biodex System, Isokinetic muscle testing, Endoscopy

Brief summary

Isokinetic muscle strength test implemented by the Biodex system is a method used for evaluating muscle function that has been applied clinically in the field of sports and rehabilitation medicine. However, information on its application on Haglund's deformity remain insufficient. Therefore, the present study is designed to examine the effectiveness of the muscle strength test using the Biodex system in evaluating the recovery of athletic capacity in patients with Haglund's deformity following endoscopic surgery.

Detailed description

Patients. A retrospective (medical records), level 3 evidence study was designed to evaluate the outcomes of patients who underwent endoscopic surgery for Haglund's deformity. The present study was approved by the Peking University Third Hospital's ethics committee. Written informed consent was obtained from all patients, parents or guardians of the patients prior to the present study. The rights of the patients were protected. Diagnosis. Patients were designed to be diagnosed based on subjective complaints, combined with clinical and radiological examinations. Radiological measurements for this disease include the Fowler-Phillip angle, calcaneal pith angle, parallel pitch lines, Chauveaux-Liet angle and the X/Y ratio.

Interventions

We classified patients by gender, age, recovery time,etc

Sponsors

Peking University Third Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients who underwent endoscopic surgery for Haglund's deformity

Exclusion criteria

* None

Design outcomes

Primary

MeasureTime frameDescription
Biodex results on both sides before surgerypre-surgeryBiodex isokinetic muscle testing system was applied in this research. Isokinetic muscle strength test is a kind of muscle function evaluation and test method, which has been applied in the research and clinical work of sports medicine and rehabilitation medicine but never on Haglund's disease before. The isokinetic muscle strength test of the flexor and dorsiflexion of the ankle joint can evaluate the muscle strength and endurance to reflect the postoperative patient's capacity for action, providing reliable clinical evidence for postoperative rehabilitation of patients after endoscopic calcaneoplasties. Isokinetic strength test conducted on both the injured and uninjured sides of the patients using the Biodex system before surgery.
Biodex results on both sides at 3 months3 months after surgeryIsokinetic strength test conducted on both the injured and uninjured sides of the patients using the Biodex system 3 months after surgery.
Biodex results on both sides at 6 months6 months after surgeryIsokinetic strength test conducted on both the injured and uninjured sides of the patients using the Biodex system 6 months after surgery.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026