SeQuent® SCB "All Comers" Post Market Clinical Follow-up (PMCF)

PMCF - Study on the Performance/Safety of SeQuent® Sirolimus-Coated Balloon (SCB, Investigational Device) in Patients With Coronary Artery Disease

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04470934
Acronym
SCORE
Enrollment
1302
Registered
2020-07-14
Start date
2021-04-30
Completion date
2027-03-31
Last updated
2026-07-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease, Myocardial Ischaemia

Keywords

Coronary Artery Disease, Myocardial Ischemia, drug-coated balloon catheter

Brief summary

The aim of the study is to assess continued safety and efficacy of the SeQuent® SCB. The product under investigation will be used in routine clinical practice according to the latest European Society of Cardiology (ESC) guidelines and according to the Instructions for Use (IFU). Those data that are obtained in routine clinical use will be documented in the Case Report Form (CRF).

Detailed description

The objective of the study is to assess the continued safety and efficacy of SeQuent® SCB for the treatment of "real world" de-novo and restenotic lesions in native coronary arteries and coronary bypass grafts. Study goals are based on non-inferiority for Drug-Coated Balloon (DCB) compared to Paclitaxel-Coated Balloon (PCB) and Dru-eluting Stents (DES) (historical data) with 80% power. Primary and secondary outcome variables are international accepted parameters in stent-trials, which sufficiently describe the efficacy and safety of the investigated device and allow clinical conclusions. Additional attention will be paid to those patients who received, by observation, a shortened dual antiplatelet therapy (DAPT). The aim of the study is to assess the safety and efficacy of the SeQuent® SCB in the treatment of coronary artery disease with reference vessel diameters between ≥ 2 mm and ≤ 4 mm with suitable lesion lengths. There is no limitation of lesion lengths. In case the lesion is longer than 34 mm, more than one stent needs to be used.

Interventions

DEVICESeQuent® SCB drug-coated balloon catheter

treatment of coronary artery disease with SeQuent® SCB of "real world" de-novo and restenotic lesions in native coronary arteries and coronary bypass grafts

Sponsors

B. Braun Melsungen AG
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* All common significant coronary lesions * Target lesion length \>34mm need to be covered with at least 2 devices * Patients eligible for this study must be at least 18 years of age * The patient must fulfil the standard recommendations for percutaneous coronary intervention (PCI), based on the last ESC recommendations within his/ her regular treatment or that the use of the product has already been decided within the regular planning of the patient's treatment

Exclusion criteria

* Intolerance to sirolimus * Allergy to components of the coating * Pregnancy and lactation * Complete occlusion of the treatment vessel because of an unsuccessfully re-canalized * Cardiogenic shock * Risk of an intraluminal thrombus * Hemorrhagic diathesis or another disorder such as gastro-intestinal ulceration or cerebral circulatory disorders which restrict the use of platelet aggregation inhibitor therapy and anti-coagulation therapy * Surgery shortly after myocardial infarction with indications of thrombus or poor coronary flow behavior * Severe allergy to contrast media * Lesions which are untreatable with PCI or other interventional techniques * Patients with an ejection fraction of \< 30 % * Vascular reference diameter \< 2.00 mm * Treatment of the left stem (first section of the left coronary artery) * Indication for a bypass surgery * Contraindication for whichever accompanying medication is necessary

Design outcomes

Primary

MeasureTime frameDescription
Target Lesion Failure (TLF)at 12 monthsTarget Lesion Failure (TLF): defined as the composite rate of target vessel myocardial infarction (TV-MI) or ischemia-driven target lesion revascularization (TLR).

Secondary

MeasureTime frameDescription
Target Lesion Failure (TLF)at 24 monthsTarget Lesion Failure (TLF): defined as the composite rate of target vessel myocardial infarction (TV-MI) or ischemia-driven target lesion revascularization (TLR).
ischemia driven target lesion revascularization (TLR)at 12 months
all-cause death, cardiac deathat 12 months
all myocardial infarction (MI) and target vessel myocardial infarction (TV-MI)at 12 months
major adverse coronary event (MACE)at 12 monthsmajor adverse coronary event (MACE): defined as composite of cardiovascular death, myocardial infarction or ischemia-driven target lesion revascularization
Dual Antiplatelet Therapy (DAPT) complianceat 4 weeks
Probable or definite stent-thrombosis of In-stent treated lesionsaccumulated at 12 months
Procedural successimmediately after procedurefinal diameter stenosis \< 30 % without flow-limiting dissections
Bleeding complications according to the Bleeding Academic Research Consortium (BARC)accumulated at 3 months

Countries

Germany

Contacts

PRINCIPAL_INVESTIGATORSylvia Otto, MD

Universitätsklinikum Jena - Klinik für Innere Medizin I

Outcome results

None listed