Skip to content

Validation of a Portable Indirect Calorimeter

Validation of the Apollo EE Device, Indirect Calorimetry

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04469452
Enrollment
35
Registered
2020-07-14
Start date
2020-09-01
Completion date
2023-11-28
Last updated
2023-12-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Human Energy Expenditure

Brief summary

This study plans to test the accuracy of a new device (the Apollo EE Device) that measures resting energy expenditure (REE) using only oxygen consumed (VO2). Findings from this study will help determine how this new device compares to the gold standard, indirect calorimetry, which measures REE using VO2 and carbon dioxide production (VCO2). Findings may help develop less expensive and more accessible means of measuring energy expenditure.

Detailed description

The gold standard for measuring resting metabolic rate (RMR) is metabolic carts that measure oxygen consumption (VO2) and carbon dioxide production (VCO2). The energy equivalent of VO2 ranges from \ 4.7-5.0 kcals/L, depending on the ratio of carbohydrate, fat, and protein oxidized. However, RMR can be measured based solely on VO2, because VCO2 has a relatively small effect on energy expenditure estimation. A device that measures RMR based on VO2 and eliminates the need for measuring VCO2 could provide a simple and less expensive alternative to metabolic carts and may have important clinical applications. The overarching goal of this proposal is to validate such a metabolic system by comparing its ability to accurately measure RMR against a metabolic cart.

Interventions

Comparisons will be made between the Apollo EE Device (Sable Systems International, Las Vegas, NV) and the TrueOne 2400 metabolic cart (Parvo Medics, Salt Lake City, UT)

Sponsors

University of Colorado, Denver
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
19 Years to 99 Years
Healthy volunteers
Yes

Inclusion criteria

* Males and females * 19-99 yrs of age

Exclusion criteria

* Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of a new indirect calorimeter, the Apollo EE Device, when compared to the gold standard (TrueOne 2400 metabolic cart)BaselineMeasurement of RMR
Reliability of a new indirect calorimeter, the Apollo EE Device, when compared to the gold standard (TrueOne 2400 metabolic cart)Repeated Measure obtained within 1 week of baseline measureRepeated measurement of RMR

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026