Skip to content

Non-invasive Transcranial Electrical Stimulation in MS

Effects of Non-invasive Transcranial Electrical Stimulation on Cognition in Patients With Multiple Sclerosis

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04466228
Enrollment
60
Registered
2020-07-10
Start date
2020-10-16
Completion date
2022-08-23
Last updated
2023-12-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cognitive Impairment, Multiple Sclerosis

Brief summary

The goal is to investigate the effects of non-invasive transcranial electrical stimulation on cognition in MS.

Detailed description

The participants' baseline cognitive function will be assessed with a tablet-based, videogame-like software specifically designed as a medical device to test and train cognitive function for populations with cognitive disorders. After baseline test assessment, participants will receive stimulation while playing the training version of the software. After the stimulation, cognitive performance will be evaluated again with the testing version. Investigators will assess changes in cognitive performance associated with stimulation.

Interventions

DEVICEnon-invasive transcranial electrical stimulation

Non-invasive transcranial electrical stimulation across the prefrontal cortex.

Sponsors

University of California, San Francisco
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* age 18-65, * diagnosis of MS * Expanded Disability Status Scale (EDSS)≤6.5, no paresis of the upper limbs * a minimum of 3 months since the last relapse * Beck Depression Inventory\<19 * normal hearing * and no changes in MS or symptomatic medications in past 2 months

Exclusion criteria

* prior brain surgery * clips in brain * epilepsy or other neurological or non-affective psychiatric disorders * pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Processing Speed Change From Baseline AssessmentBaseline (pre-stim) and post-stimulation (up to 2 hours)Symbol Digit Modalities Test (SDMT) score will be used to measure processing speed. SDMT measures the time to pair abstract symbols with specific numbers. The test requires visuoperceptual processing, working memory, and psychomotor speed. The score is the number of correctly coded items in 90 seconds. (max=110, min=0). Higher scores indicate improvement. Lower scores indicate worsening.
EVO Performance Change From Baseline AssessmentBaseline (pre-stim) and post-stimulation, up to 2 hoursEVO tool is a digital cognitive assessment developed to assess cognitive function including attention and related cognitive control processes in clinical populations. It comes with the closed-loop adaptive algorithm which makes proportional changes in gameplay difficulty when the participant's performance deviates from an 80% rate of accuracy, which ensures that task difficulty is equated across participants and enhances engagement. Gameplay threshold (level 0 to level 20), response time and response time variability will be measured to evaluate attention control. Higher threshold level, lower response time and smaller response time variability indicate improvement.

Countries

United States

Participant flow

Participants by arm

ArmCount
Stim1 High Dose
This group will receive high dose non-invasive transcranial electrical stimulation non-invasive transcranial electrical stimulation: Non-invasive transcranial electrical stimulation across the prefrontal cortex.
20
Stim2 Low Dose
This group will receive low dose non-invasive transcranial electrical stimulation non-invasive transcranial electrical stimulation: Non-invasive transcranial electrical stimulation across the prefrontal cortex.
20
Sham Control
This group will receive sham control non-invasive transcranial electrical stimulation non-invasive transcranial electrical stimulation: Non-invasive transcranial electrical stimulation across the prefrontal cortex.
20
Total60

Baseline characteristics

CharacteristicStim1 High DoseTotalSham ControlStim2 Low Dose
Age, Continuous48.7 years
STANDARD_DEVIATION 7.6
46.3 years
STANDARD_DEVIATION 8.5
47.4 years
STANDARD_DEVIATION 8
42.8 years
STANDARD_DEVIATION 9.3
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
3 Participants8 Participants2 Participants3 Participants
Race (NIH/OMB)
Black or African American
1 Participants1 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
2 Participants11 Participants3 Participants6 Participants
Race (NIH/OMB)
White
14 Participants40 Participants15 Participants11 Participants
Region of Enrollment
United States
20 Participants60 Participants20 Participants20 Participants
Sex: Female, Male
Female
17 Participants48 Participants17 Participants14 Participants
Sex: Female, Male
Male
3 Participants12 Participants3 Participants6 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
deaths
Total, all-cause mortality
0 / 200 / 200 / 20
other
Total, other adverse events
0 / 200 / 200 / 20
serious
Total, serious adverse events
0 / 200 / 200 / 20

Outcome results

Primary

EVO Performance Change From Baseline Assessment

EVO tool is a digital cognitive assessment developed to assess cognitive function including attention and related cognitive control processes in clinical populations. It comes with the closed-loop adaptive algorithm which makes proportional changes in gameplay difficulty when the participant's performance deviates from an 80% rate of accuracy, which ensures that task difficulty is equated across participants and enhances engagement. Gameplay threshold (level 0 to level 20), response time and response time variability will be measured to evaluate attention control. Higher threshold level, lower response time and smaller response time variability indicate improvement.

Time frame: Baseline (pre-stim) and post-stimulation, up to 2 hours

Population: EVO performance change from baseline assessment was not measured in the study. Therefore the analysis was not performed.

Primary

Processing Speed Change From Baseline Assessment

Symbol Digit Modalities Test (SDMT) score will be used to measure processing speed. SDMT measures the time to pair abstract symbols with specific numbers. The test requires visuoperceptual processing, working memory, and psychomotor speed. The score is the number of correctly coded items in 90 seconds. (max=110, min=0). Higher scores indicate improvement. Lower scores indicate worsening.

Time frame: Baseline (pre-stim) and post-stimulation (up to 2 hours)

Population: The present report covers all collected data. In a formal data analysis, three participants were excluded from the analyses: 2 due to poor performance at baseline (lower than 2 standard deviation of all 60 participants); and 1 for not following instructions properly during post-stim assessment.

ArmMeasureGroupValue (MEAN)Dispersion
Stim2 Low DoseProcessing Speed Change From Baseline Assessmentpre-stim41.65 score on a scaleStandard Error 2.65
Stim2 Low DoseProcessing Speed Change From Baseline Assessmentpost-stim46.1 score on a scaleStandard Error 2.81
Stim1 High DoseProcessing Speed Change From Baseline Assessmentpost-stim44.8 score on a scaleStandard Error 2.82
Stim1 High DoseProcessing Speed Change From Baseline Assessmentpre-stim42.05 score on a scaleStandard Error 2.68
Sham ControlProcessing Speed Change From Baseline Assessmentpre-stim44.4 score on a scaleStandard Error 1.8
Sham ControlProcessing Speed Change From Baseline Assessmentpost-stim44.8 score on a scaleStandard Error 1.4

Source: ClinicalTrials.gov · Data processed: Feb 8, 2026