Skip to content

Rapid, Onsite COVID-19 Detection

Rapid, Onsite COVID-19 Detection

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04460690
Enrollment
93
Registered
2020-07-07
Start date
2020-07-13
Completion date
2021-03-31
Last updated
2022-01-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

COVID-19, Sars-CoV2

Keywords

rapid detection, assay, saliva, coronavirus

Brief summary

The purpose of this research study is to evaluate and improve a rapid COVID-19 test. The test is designed to identify people who are most contagious and likely to spread the virus to others. This test will be performed at various locations in the Madison area using a mobile laboratory or standard lab space for processing. Saliva samples can be collected and processed at these locations or participants can self-collect at home and drop their samples off at designated locations for same day processing. Results of potential findings of clinical significance will be communicated to the participants by a physician with appropriate expertise on the study team. Individuals with a potential finding of clinical significance will be encouraged to self-isolate and obtain a diagnostic test at their earliest convenience. No results will be given if the test is negative. If the participant consents, advanced molecular testing such as PCR or viral sequencing can be done and results can be shared via online databases, presentations and publications along with the date, site and county of collection to help facilitate tracking the spread of the virus.

Detailed description

Virtually all COVID-19 RNA assays require centralized laboratories. Samples collected in locations including public testing sites, workplaces, nursing homes, and residential housing are transported to centralized laboratories for testing, leading to lengthy delays in results reporting. The window of maximal contagiousness is thought to be only a few days, so these delays create the risk of excess transmission. Current testing methods are painful, which encourages testing hesitancy. Rapid, onsite detection of SARS-CoV-2 RNA from non-invasive saliva could overcome these issues and provide a pathway to high-throughput detection of people at the greatest risk of SARS-CoV-2 transmission but the logistics of such a testing program require real-world prototyping. The investigators have developed a simple test to detect high concentrations of SARS-CoV-2 in saliva with assays that require no specialized equipment and can be completed in one hour. This assay is not diagnostic for SARS-CoV-2; instead, it specifically identifies saliva samples that have high amounts of viral RNA that are correlated with live virus shedding. Many samples that would be identified as SARS-CoV-2 by diagnostic qRT-PCR would be negative with this saliva assay. Conversely, detection of RNA in saliva is a potential finding of clinical significance, so participants with that result will be contacted by a medical professional to discuss potential follow-up with their own health care provider, including a possible independent diagnostic testing. Because the assay requires no specialized equipment, it can be performed at the site of sample collection using a portable laboratory that fits in the backseat of a car. The prototype testing will take place in a variety of settings that may include parking lots, workplaces, nursing homes and residential housing. Participants will be asked to consent to provide a saliva sample that will be tested for SARS-CoV-2 RNA levels consistent with live virus shedding. The consent document will explicitly state that this is not a diagnostic test for SARS-CoV-2 but that a potential finding of clinical significance should be discussed with a medical professional. Participants can opt-out of receiving any results at the time of consent and can provide samples for the sole purpose of contributing to community surveillance and assay development. Paper consent forms will be reviewed and signed and held by team members in a secure location (locked box at the collection site) until taken back to the AIDS Vaccine Research Laboratory for storage. Participants will then spit into a coded vessel (e.g., cup or tube). Samples should be at least 1ml (\ ¼ teaspoon) and will be assayed for the presence of SARS-CoV-2 RNA using the aforementioned detection assay; the presence of high concentrations of SARS-CoV-2 RNA is indicated by a colorimetric change from pink to yellow/orange.

Interventions

DEVICERapid Onsite COVID-19 Detection

saliva assay test for high concentrations of SARS-CoV-2

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
AIDS Vaccine Research Lab
CollaboratorUNKNOWN
University of Wisconsin, Madison
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
5 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Willing to provide informed consent * Willing to provide informed consent and spit into a vessel * Individuals at least 5 years of age and have a parent or legal guardian present to consent if under 18 years * Adult participants must have decision-making capacity to provide consent on their own behalf. * Participants must be able to speak English

Exclusion criteria

* Under 18 years of age with no parent or legal guardian present or under the age of 5 yrs * Participants must not have visual or hearing impairments, or low literacy, that would prevent them from reading the consent form and interacting with a member of the research team to ask questions and receive responses during the consent process

Design outcomes

Primary

MeasureTime frameDescription
Number of Samples Tested15 minutessamples are tested and consistently shown that the assay can detect SARS-CoV-2 safely, consistently and accurately at multiple locations using the mobile laboratory.
Safety: Number of Participants Who Tested Positive for COVID-19up to 2 monthsFeasibility is determined when at least 10000 samples are tested and consistently shown that the assay can detect SARS-CoV-2 safely, consistently and accurately at multiple locations using the mobile laboratory. This testing protocol will be considered safe if COVID-19 rates of those performing the tests do not significantly exceed those of the communities in which the tests are being performed.

Countries

United States

Participant flow

Participants by arm

ArmCount
Rapid Onsite COVID-29 Testing - Investigators
Community participants provide a saliva sample for a simple test to detect high concentrations of SARS-CoV-2 in saliva with assays that require no specialized equipment and can be completed in one hour. Rapid Onsite COVID-19 Detection: saliva assay test for high concentrations of SARS-CoV-2
10
Rapid Onsite COVID-29 Testing - Participants
Community participants provide a saliva sample for a simple test to detect high concentrations of SARS-CoV-2 in saliva with assays that require no specialized equipment and can be completed in one hour. Rapid Onsite COVID-19 Detection: saliva assay test for high concentrations of SARS-CoV-2
83
Total93

Baseline characteristics

CharacteristicTotalRapid Onsite COVID-29 Testing - InvestigatorsRapid Onsite COVID-29 Testing - Participants
Age, Customized0 Participants
Race and Ethnicity Not Collected0 Participants
Region of Enrollment
United States
93 Participants10 Participants83 Participants
Sex/Gender, Customized
any gender
0 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 00 / 0
other
Total, other adverse events
0 / 00 / 0
serious
Total, serious adverse events
0 / 00 / 0

Outcome results

Primary

Number of Samples Tested

samples are tested and consistently shown that the assay can detect SARS-CoV-2 safely, consistently and accurately at multiple locations using the mobile laboratory.

Time frame: 15 minutes

Population: 3692 samples were collected from 93 participants.

ArmMeasureValue (COUNT_OF_UNITS)
Rapid Onsite COVID-29 TestingNumber of Samples Tested3692 samples
Primary

Safety: Number of Participants Who Tested Positive for COVID-19

Feasibility is determined when at least 10000 samples are tested and consistently shown that the assay can detect SARS-CoV-2 safely, consistently and accurately at multiple locations using the mobile laboratory. This testing protocol will be considered safe if COVID-19 rates of those performing the tests do not significantly exceed those of the communities in which the tests are being performed.

Time frame: up to 2 months

Population: The participants included people from the community and team members performing the tests.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Rapid Onsite COVID-29 TestingSafety: Number of Participants Who Tested Positive for COVID-1916 Participants
Investigator ParticipantsSafety: Number of Participants Who Tested Positive for COVID-190 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026