Skip to content

A Single Center Study on Comparing the Different Function of EndoAngel in Improving the Quality of Colonscopy

A Prospective, Randomized, Single-blind, 2 × 2 Factorial Design Single Center Study Evaluating the Polyp Detection and Quality Monitoring Function of EndoAngel in Improving the Quality of Colonoscopy

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04453956
Enrollment
1090
Registered
2020-07-01
Start date
2020-07-01
Completion date
2020-10-30
Last updated
2020-10-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Adenoma

Keywords

Polyp Detection, Quality Monitoring, Artificial Intelligence

Brief summary

An artificial intelligence-based system, named EndoAngel,has been constructed previously,which has polyp detection and quality monitoring functions. This study aims to evaluate the two different functions of EndoAngle in improving adenoma detection rate.

Detailed description

The detection and removal of precancerous polyps via colonoscopy can reduce the the risk of colon cancer. However, the detection rate of adenomatous polyps can vary significantly among endoscopists. EndoAngel is an artificial intelligence-based system,consisting of polyp detection and quality monitoring functions. The polyp detection function can remind endoscopists of the location of the polyp. The quality monitoring function can monitor the velocity of insertion of the endoscope, record the time of insertion and withdrawal of the endoscope, and remind endoscopists of the blind areas caused by intestinal segment slipping.This study aims to evaluate the two different functions of EndoAngle by 2 × 2 factorial design in improving adenoma detection rate and the quality of colonscopy .

Interventions

DIAGNOSTIC_TESTColonoscopy with the assistance of EndoAngel's polyp detection function.

Patient in this group will receive colonoscopy with assistance of EndoAngel's polyp detection function,which can remind endoscopists of the location of the polyp.

DIAGNOSTIC_TESTColonoscopy with the assistance of EndoAngel's quality monitoring function.

Patient in this group will receive colonoscopy with assistance of EndoAngel's quality monitoring function,which can monitor the withdrawal speed of the endoscope.

DIAGNOSTIC_TESTColonoscopy without the assistance of EndoAngel's any function.

Patient in this group will receive colonoscopy with assistance of EndoAngel's both functions.

Sponsors

Renmin Hospital of Wuhan University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
FACTORIAL
Primary purpose
DIAGNOSTIC
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Male or female aged 18 years or above; 2. Colonoscopy is needed to further characterize gastrointestinal diseases; 3. Ability to read, understand and sign informed consent forms; 4. The researchers believe that the subjects can understand the process of the clinical study and are willing and able to complete all the study procedures and follow-up visits to cooperate with the study procedures.

Exclusion criteria

1. Participated in other clinical trials, signed informed consent forms and followed up in other clinical trials; 2. Participate in a drug clinical trial and during the elution period of the trial or control drug; 3. Drug or alcohol abuse or mental disorder in the last 5 years; 4. Pregnant or lactating women; 5. Patients with multiple polyp syndrome; 6. Patients with a history of inflammatory bowel disease, colorectal cancer, or colorectal surgery; 7. Patients with known perforation or colonic obstruction; 8. Patients with a contraindication for biopsy; 9. The researchers did not consider the subjects suitable for colonoscopy; 10. The researchers determined that the subjects had high-risk diseases or other special conditions that were not appropriate for clinical trials.

Design outcomes

Primary

MeasureTime frameDescription
Adenoma detection rate3 MonthsThe numerator is the number of cases of adenomas detected by colonoscopy, and the denominator is the total number of cases of patients undergoing colonoscopy.

Secondary

MeasureTime frameDescription
The mean number of polyps per procedure3 monthsThe numerator is the total number of polyps detected by colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
The mean number of adenomas per procedure3 monthsThe numerator is the total number of adenomas detected by colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
Detection rate of large, small and diminutive polyps3 monthsThe numerator was the number of patients with large (≥10 mm), small (\>5 to \<10 mm), and diminutive(≤5 mm) polyps detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy.
The mean number of large, small and diminutive polyps per procedure3 monthsThe numerator was the number of large (≥10 mm), small (\>5 to \<10 mm), and diminutive(≤5 mm) polyps detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy.
Detection rate of large, small and diminutive adenomas3 monthsThe numerator was the number of patients with large (≥10 mm), small (\>5 to \<10 mm), and diminutive(≤5 mm) adenomas detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy.
Polyp detection rate3 monthsThe numerator is the number of cases of polyps detected by colonoscopy, and the denominator is the total number of cases of patients undergoing colonoscopy.
Detection rate of adenoma in different sites3 monthsThe numerator is the number of cases of adenoma detected in the rectum, sigmoid colon, descending colon, transverse colon, ascending colon and ileocecal region during colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
The mean number of adenomas in different sites per procedure3 monthsThe numerator is the total number of adenomas detected in the rectum, sigmoid colon, descending colon, transverse colon, ascending colon and ileocecal region during colonoscopy, and the denominator is the total number of patients undergoing colonoscopy.
Time of colonoscopic insertion3 monthsThe duration of colonoscopic insertion from rectum to ileocecal valve or appendiceal opening
Time of colonoscopic withdrawal3 monthsThe duration of colonoscopic withdrawal from ileocecal valve or appendiceal opening to colonoscopy finished.
Cecal intubation rate3 monthsThe numerator is the number of cases of colonoscopy reaching ileocecal valve or appendiceal opening, and the denominator is the total number of colonoscopy cases.
The mean number of large, small and diminutive adenomas per procedure3 monthsThe numerator was the number of large (≥10 mm), small (\>5 to \<10 mm), and diminutive(≤5 mm) adenomas detected by colonoscopy, and the denominator was the total number of patients receiving colonoscopy.

Countries

China

Contacts

Primary ContactHonggang Yu, MD
yuhonggang1968@163.com+8613871281899

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026