Skip to content

Prevention of Endotracheal Tube Migration by Cuff Palpation During Robotic Surgical Procedure

To Evaluate Three Point Cuff Palpation Technique for Assessing Optimal Depth of Endotracheal Tube Placement.

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04440787
Enrollment
100
Registered
2020-06-22
Start date
2018-12-01
Completion date
2021-03-31
Last updated
2020-06-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Robotic Surgical Procedures

Keywords

Endotracheal intubation, pneumoperitoneum, trendelenburg position, Robotic surgery

Brief summary

After intubation, the endotracheal tube was finally fixed after palpating endotracheal cuff at three sites (just below the cricoid cartilage, at suprasternal level and just below suprasternal notch). Fibre optic bronchoscopy will be done to find distance between tip of endotracheal tube and carina. This distance will be measured repeatedly, after pneumoperitoneum, after trendelenburg position and after making the patient supine at the end of surgery. Change in the distance will be noted.

Detailed description

The endotracheal tube (ETT) will be placed according to the black mark on the tube, post-intubation, the tube will be finally fixed after palpating endotracheal cuff at three sites (below cricoid cartilage, at suprasternal level and just below suprasternal notch). ETT cuff position will be scanned by sonography of airway to confirm the position of the proximal end of the ETT cuff. Fibre optic bronchoscopy will be done to find distance between tip of endotracheal tube and carina. This distance will be measured repeatedly 5 minutes after pneumoperitoneum, 10 minutes after trendelenburg position and 10 minutes after making the patient supine at the end of surgery. Change in the distance will be noted to confirm the migration of ETT.

Interventions

PROCEDUREThree point cuff palpation technique

the ETT is finally positioned according to the Three point cuff technique.

Sponsors

Rajiv Gandhi Cancer Institute & Research Center, India
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* Robotic uro-oncological surgical procedures of perineum * Robotic gynae-oncological surgical procedures of perineum

Exclusion criteria

* Upper airway fibrosis or tracheal stenosis * Large neck swelling distorting or deviating the trachea. * Head and neck surgeries * Laryngeal and tracheal tumour * Tracheal surgery * Previous tracheostomy * previous radiation treatment of neck

Design outcomes

Primary

MeasureTime frameDescription
Measure the distance between tip of endotracheal tube and Carina by fiber-optic bronchoscopy and measuring scale at various phases of robotic surgical procedure.Throughout robotic surgical procedure, immediately after intubation, 5 minute after pneumoperitoneum, 10 minutes after trendelenburg position and after dedocking and making patient supine.pneumoperitoneum.proper endotracheal tube placement is labelled when the distance between the tip of tube and Carina is more than 2.5 cm, after placement the tube by three point cuff palpation technique, its position will be assessed at respective time points.

Secondary

MeasureTime frameDescription
find the effect of cricod cartilage and supra-sternal distance on endotracheal tube tip to Carina distance.Throughout robotic surgical procedure, immediately after intubation, 5 minute after pneumoperitoneum, 10 minutes after trendelenburg position and after dedocking and making patient supine.cricoid cartilage to suprasternal distance changes with the position of neck, so it could affect the distance between the endotracheal tube tip and carina as the position of patient changes during various robotic surgical steps.

Countries

India

Contacts

Primary ContactAmit Kr Mittal, M.D
amitrgci@gmail.com01147022323
Backup ContactMamta Dubey, MD
ek_mamta@yahoo.co.in09891105744

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026