Effect of OXSIGHT Smart Glasses on Patients With Advanced Glaucoma

Effect of OXSIGHT Smart Glasses on Patients With Advanced Glaucoma

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04434612
Acronym
OXSIGHT
Enrollment
30
Registered
2020-06-17
Start date
2020-06-06
Completion date
2021-12-31
Last updated
2020-06-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Advanced Glaucoma

Keywords

OXSIGHT, advanced glaucoma, low vision aids, head-mounted electronic devices

Brief summary

Glaucoma is the leading cause of irreversible blindness worldwide. The visual function of patients with advanced glaucoma is severely impaired, and the vision-related activities (e.g. movement, reading) are obviously restricted, which may have a negative impact on the patients' quality of life (QOL) and increase the burden on individuals and families. Low vision aids (LVAs) and other devices for vision rehabilitation (VR) are useful for patients with advanced glaucoma to maximize the function of residual vision and improve the QOL. OXSIGHT smart glasses are the latest LVAs eyeglasses that are expected to improve the QOL for patients with low vision (LV), such as those with glaucoma. Clinical data were collected to evaluate the efficacy and its influencing factors of OXSIGHT smart glasses in patients with advanced glaucoma, in providing theoretical basis for subsequent clinical studies.

Detailed description

1. Glaucomatous low vision. Glaucoma is a chronic eye disease that causes irreversible damage to the optic nerve and can lead to severe vision loss and blindness. Low vision (LV) is a decrease in vision that cannot be corrected with standard glasses, contact lenses, medication or surgery, impairing a person's ability to perform age-appropriate vision-dependent tasks. 2. Low vision rehabilitation. Low Vision Rehabilitation (LVR) is part of the continuum of eye care that extends from diagnosis to treatment and rehabilitation, designed to help visually impaired patients retain vision to the maximum, make activities easier to perform, regain independence, and improve their QOL. LVR services include comprehensive assessment of visual function, prescription of LVAs, rehabilitation training and referrals to a range of community services and psychosocial support. 3. Research status of intelligent head-mounted devices. In recent years, video head-mounted devices have been gradually applied in the field of VR, with the advantages of high definition, diverse processing modes, adjustable magnification, contrast and brightness, which overcome the limitations of traditional devices, like eSight 3, NuEyes, and IrisVision. However, studies on the effectiveness of head-mounted electronic LVAs are quite limited. 4. OXSIGHT smart glasses. OXSIGHT smart glasses, the latest generation of head-mounted electronic LVAs, developed by the team of Oxford University in the UK, are designed for LV patients with visual field defects. Based on the previous generation, OXSIGHT has the advantages of lighter weight, comfortable wearing, better imaging quality, multi-mode assisted visual recognition and so on. However, the efficacy and influencing factors of OXSIGHT smart glasses on advanced glaucoma patients remain unclear, and further studies are needed.

Interventions

DEVICEOXSIGHT smart glasses

OXSIGHT smart glasses are head-mounted electronic LVAs designed for LV patients with visual field loss.

Sponsors

Zhongshan Ophthalmic Center, Sun Yat-sen University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
10 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. age ≥10 years, able to complete all tests and inspections; 2. a definite diagnosis of primary or secondary glaucoma or glaucoma in children; 3. the best corrected visual acuity of the better eye is no more than 0.3 and better than 0.05; visual field ≤10° and MD value \< -12db; 4. Visual acuity, intraocular pressure, and other eye conditions have been stable for more than 6 months.

Exclusion criteria

1. unable to cooperate with related inspections; 2. a history of eye surgery or eye laser within 6 months; 3. diseases that interfere with the diagnosis of glaucoma, such as optic disc dysplasia, obvious anisometropia, retinal vascular diseases, optic nerve diseases, macular degeneration, cerebrovascular diseases, etc.; 4. pregnant or lactating women; 5. those who refuse to sign the informed consent or voluntarily withdraw from the study due to discomfort or other reasons.

Design outcomes

Primary

MeasureTime frameDescription
Changes from baseline CLVQOL scores at different time pointsThe examination was performed at 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after intervention.The Low vision Quality of Life Questionnaire (LVQOL) specifically investigates the QOL of visually impaired patients. The questionnaire consists of 25 closed items and examines four dimensions: distance vision, mobility and lighting; adjustment; reading and fine work; daily activities. As a convenient tool, LVQOL is widely used in clinical settings to evaluate effects of clinical treatment and corresponding strategies of low-vision rehabilitation. CLVQOL is the Chinese version of LVQOL.

Secondary

MeasureTime frameDescription
Changes from baseline visual acuity at different time pointsThe examination was performed at 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after intervention.ETDRS visual acuity chart was used.
Changes from baseline contrast sensitivity at different time pointsThe examination was performed at 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after intervention.Pelli-Robson Contrast Sensitivity Charts were used.
Changes from baseline visual field at different time pointsThe examination was performed at 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after intervention.Visual field was measured by the kinetic perimetry test of Humphrey field analyzer.
Changes from baseline scores of mobility test at different time pointsThe examination was performed at 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after intervention.A mobility test was performed to evaluate patients' functionality in 2 scenarios: using their best-corrected visual acuity with no LVAs and using the OXSIGHT Smart Glasses. A loop-shaped obstacle course consisting of stationary obstacles from floor to head level was designed for this test.

Contacts

Primary ContactYiqing Li, doctor
liyiqing@gzzoc.com13302235127
Backup ContactZhidong Li, doctor
aiyou1989@163.com15521059530

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026