Skip to content

Rapid Breath-hold Quantitative Macromolecular Proton Fraction Imaging for Liver Fibrosis

Assessment of Fibrosis by Non-invasive Quantitative Imaging of Collagen in the Liver Using Breath-hold MRI With Comparison With MR Elastography and Liver Biopsy

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04429100
Enrollment
200
Registered
2020-06-12
Start date
2020-03-01
Completion date
2027-12-30
Last updated
2026-03-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Liver Fibrosis

Keywords

magnetic resonance imaging, quantitative imaging, spin-lock

Brief summary

Chronic liver disease is a major health problem worldwide. Liver fibrosis is a key feature in most chronic liver diseases. When identified early, liver fibrosis may be reversible. Currently, liver biopsy is the gold standard for the diagnosis of liver fibrosis. Liver biopsy; however, is invasive. Non-invasive diagnostic tools are increasingly used in clinical practice. However, the existing noninvasive methods still have significant limitations to detect early-stage liver fibrosis. Liver fibrosis is characterized by excessive deposition of collagen-rich connective tissues in the liver. The macromolecular proton fraction (MPF) is an MRI parameter which characterizes the magnetization transfer (MT) effect in tissues. Quantitative MPF imaging is non-invasive and can be used to measure collagen deposition in the liver due to the strong MT effect of collagen. It has been reported MPF quantification can be used for diagnosis of early-stage liver fibrosis. However, the existing approaches require B1, B0, and T1 map in addition to the imaging data for MPF quantification, which makes it challenging to adopt them for routine clinical use. The investigators propose a fast and robust MPF quantification approach. In contrast to the existing methods which rely on saturation radiofrequency pulses for MPF quantification, our approach is based on spin-lock radiofrequency pulses which have minimum Rabi oscillations. The whole imaging data can be acquired within a breath-hold less than 8 seconds. Our approach only needs a B1 map in addition to the imaging data for MPF quantification. The preliminary clinical studies on 3.0T MRI show the measurement using our approach is specific to collagen content and can be used to detect early-stage liver fibrosis. To further confirm the clinical value of the proposed approach, the investigators will investigate the relationship of the collagen content measured using the proposed non-invasive imaging approach and those measured based on morphometry analysis of histology, and determine the diagnostic value of the proposed method for detection of early stage liver fibrosis in a large cohort. The investigators will also perform comparative studies of the proposed method and the state-of-the-art quantitative MPF imaging technique. This project will provide a diagnostic technology for early detection of liver fibrosis. The proposed MRI technology also has potential to be used for other clinical purposes.

Interventions

DIAGNOSTIC_TESTMagnetic Resonance Imaging

One novel MRI sequence, i.e. the quantitative imaging of macromolecular proton fraction (MPF), will be introduced into this study. MPF is defined as the relative amount of protons associated with macromolecules involved in magnetization exchange with free water protons. This parameter is independent of the pool model used for quantification and the pulse sequences used for data acquisition. Recent studies have found a strong association between MPF and collagen content in the fibrotic liver, indicating MPF is a potential biomarker of early-stage liver fibrosis.

Sponsors

Chinese University of Hong Kong
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL

Inclusion criteria

1. Patient group * patients with histology-proven liver fibrosis, including those with liver fibrosis stage F0, early-stage liver fibrosis (F1-2), and late stage. liver fibrosis(F3-4). * patient aged 18 years old and above. 2. Healthy control group * controls aged 18 years old and above.

Exclusion criteria

* Contraindications to MRI, such as cardiac pacemaker, claustrophobia, pregnancy, metallic implants not suitable for MRI scan.

Design outcomes

Primary

MeasureTime frameDescription
diagnostic accuracy3 yearsdiagnostic accuracy of quantitative macromolecular proton fraction imaging based on spin-lock (MPF-SL) for detecting early-stage liver fibrosis.

Secondary

MeasureTime frameDescription
correlation coefficient3 yearscorrelations between the MPF quantification and the morphometric scores

Countries

Hong Kong

Contacts

CONTACTWeitian Chen, PhD
wtchen@cuhk.edu.hk3505 1036

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 20, 2026