Skip to content

The BCI 602 BONEBRIDGE Post-Market Clinical Follow-up Study

The BCI 602 BONEBRIDGE Post-Market Clinical Follow-up Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04427033
Enrollment
52
Registered
2020-06-11
Start date
2019-12-06
Completion date
2024-01-18
Last updated
2026-08-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hearing Loss, Hearing Loss, Bilateral, Hearing Loss, Conductive, Hearing Loss, Mixed, Hearing Loss, Sensorineural, Hearing Loss, Unilateral

Keywords

Bonebridge system, BCI 601, BCI 602, bone conduction, bone conduction implant

Brief summary

The Bonebridge system using the BCI 601 is marketed since 2012. Previous prospective, multi-center, non-randomized studies on the BCI 601 Bonebridge performed in adult and paediatric populations have shown a significant improvement in terms of aided sound field (SF) thresholds, word recognition scores (WRS), speech reception thresholds (SRT) and subjective device satisfaction. Safety was established by stable residual hearing and low complication rates. The Bonebridge, implanted in over 600 clinics worldwide, is the world's first active transcutaneous bone conduction implant (BCI) system. This study now focuses on the further developed BCI 602 (marketed since 2019) that has the same indication criteria and performance characteristics. The aim of this post-market clinical follow-up (PMCF) study is to provide clinical data for the long-term performance and safety when implanted with the Bonebridge BCI 602 .

Interventions

DEVICEBone Conduction Implant

Bonebridge system BCI 602

Sponsors

MED-EL Elektromedizinische Geräte GesmbH
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Age
5 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Geographically and physically able to return to the investigational site for scheduled evaluations and follow-up appointments * Fluent in the language used in the investigational site and used for evaluation * Signed and dated informed consent before the start of any study-specific procedure and collection of any retrospective data. * Subjects meet the indication criteria according to the instructions for use (IFU): * Subject 5 years of age and older * The physician must fully assess the potential risks and benefits for the patient and his/her realistic expectations with the device prior to the decision to implant the BCI 602. The physician must exercise medical judgement and consider the patient's complete medical history. * Bonebridge candidates suffer from either * • conductive or mixed hearing loss as indicated by audiometric testing with bone conduction thresholds better than or equal to 45 dB HL at 0.5, 1.0, 2.0 and 3.0 kHz. * • single-sided sensorineural deafness, that is severe-to-profound sensorineural hearing loss in one ear while the other ear has normal hearing (air conduction (AC) should be better than or equal to 20 dB HL measured at 0.5, 1.0, 2.0 and 3.0 kHz).

Exclusion criteria

* A subject whose hearing loss has demonstrated an improving and decreasing fluctuation over a two-year period of \>15 dB HL in either direction * Severe, chronic, non-revisable diseases or disorders (vestibular disorder, cancer etc.) * A subject with any psychological (anxiety, depression, hallucinations etc.), emotional (schizophrenia, mania, melancholia etc.) or from that originating physical disorder that would interfere with the ability to perform on test procedures * Simultaneous participation in another clinical trial (on device or on drug) which would interfere with the results of the study. * Any active ear infection * Subjects who meet any of the contraindications in the IFU: * Evidence that hearing loss is of retrocochlear or central origin (ipsilateral CHL /MHL; contralateral SSD) * Skin or scalp conditions that may preclude attachment of the Audio Processor (AP) or that may interfere with the use of the AP * Skull size or abnormality would preclude appropriate placement of the BCI 602 implant * Intolerant to the materials in the BCI 602 implant.

Design outcomes

Primary

MeasureTime frameDescription
Sound Field audiometry12 months post-operativeInvestigate if the PTA4 sound field thresholds (SF) improve with the BCI 602 (aided) at 12 months post-operative compared to the unaided test situation. (PTA4 = average of audiometric test frequencies 0.5, 1.0, 2.0, 4.0 kHz)

Secondary

MeasureTime frameDescription
Word Recognition Score (CHL/MHL)12 months post-operativeInvestigate if speech intelligibility improves with the BCI 602 (aided) at 12 months post-operative compared to the unaided test situation in the following speech intelligibility test. Word Recognition Score (WRS): S0°, WRS correct @ 65 dB SPL Signal Monosyllabic (MS) word lists are presented from the front (0°) at 65 dB SPL (45 dB HL) and the percent correct score \[%\] (0 % to 100 %) is recorded. (SPL= Sound Pressure Level; Score: 0% to 100% words understood )
Speech Reception Threshold in quiet (CHL/MHL)12 months post-operativeInvestigate if speech intelligibility improves with the BCI 602 (aided) in CHL/MHL at 12 months post-operative compared to the unaided test situation in the following speech intelligibility test. Speech Reception Threshold in quiet (SRT) : S0°, SRT for 50% correct
Speech Reception Threshold in noise (CHL/MHL)12 months post-operativeInvestigate if speech intelligibility improves with the BCI 602 (aided) in CHL/MHL at 12 months post-operative compared to the unaided test situation in the following speech intelligibility test. Speech Reception Threshold in noise (SNR): S0° N0°, SNR for 50% correct @ 65 dB SPL Noise
Speech Reception Threshold in noise (SSD) Sssd Nnh12 months post-operativeInvestigate if speech intelligibility improves with the BCI 602 (aided) in SSD at 12 months post-operative compared to the unaided test situation in the following speech intelligibility tests. Sssd Nnh, SNR for 50% correct @ 65 dB SPL Noise (S= Signal; N= Noise; ssd = single sided deaf ear; nh = normal hearing ear)
Speech Reception Threshold in noise (SSD) S0° Nnh12 months post-operativeInvestigate if speech intelligibility improves with the BCI 602 (aided) in SSD at 12 months post-operative compared to the unaided test situation in the following speech intelligibility tests. S0° Nnh, SNR for 50% correct @ 65 dB SPL Noise
Residual hearing12 months post-operativeInvestigate whether residual hearing by means of bone conduction (BC) PTA4 thresholds of subjects implanted with the BCI 602 remains stable 12 months post-operative compared to the pre operative test situation.
Adverse Events12 months post-operativeMonitor the long-term safety of subjects implanted with the BCI 602 by collecting and reviewing adverse events (AEs).
Surgical Questionnaires12 months post-operativeMonitor the long-term safety of subjects implanted with the BCI 602 by administering a surgical evaluation questionnaire to the surgeon.
Speech Spatial Qualities questionnaire12 months post-operativeInvestigate the Quality of Life with the SSQ questionnaire of subjects implanted with the BCI 602 12 months post-operative. (SSQ = Speech Spatial Qualities)
Assessment Quality of Life questionnaire12 months post-operativeInvestigate the Quality of Life with the AQoL questionnaire of subjects implanted with the BCI 602 12 months post-operative. (AQoL= Assessment Quality of Life)

Countries

Austria, Germany, United Kingdom

Contacts

PRINCIPAL_INVESTIGATORAssen Koitschev, Prof. Dr.

Klinikum Stuttgart - Olgahospital and Eberhard-Karls-Universität Tübingen

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 18, 2026