Skip to content

The Efficacy and Safety of Faster Insulin Aspart (Fiasp®) Compared to Conventional Insulin Aspart (NovoLog®) as Correction Bolus

The Efficacy and Safety of Faster Insulin Aspart (Fiasp®) Compared to Conventional Insulin Aspart (NovoLog®) as Correction Bolus in Patients With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion (CSII) and Continuous Glucose Monitoring (CGM): a Cross-over Controlled Trial

Status
UNKNOWN
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04414579
Acronym
PLATEAU
Enrollment
45
Registered
2020-06-04
Start date
2019-03-27
Completion date
2021-03-31
Last updated
2020-11-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Type 1 Diabetes Mellitus

Keywords

continuous glucose monitoring, continuous subcutaneous insulin infusion, hyperglycemia, correction bolus

Brief summary

The purpose of this investigator-initiated trial is to compare the efficacy in terms of time to recovery from hyperglycemia as measured by time to arrest of hyperglycemic excursion (glucose plateau point, primary endpoint) and return to premeal glucose target if feasible (secondary endpoint) between Fiasp and conventional insulin aspart when used as a correction bolus. These endpoints will be determined by CGM (Dexcom) from data exported from the Dexcom Clarity program.

Detailed description

Patients with type 1 DM using CSII require bolus insulin for two purposes: first, to cover carbohydrate intake to control postprandial glucose, and second, to correct episodes of hyperglycemia. The latter function is referred to as a correction dose or correction bolus. Insulin pumps have bolus calculators which calculate correction doses based on the patient's individualized BG target and insulin sensitivity factor (ISF). Rapid-acting insulin analogues delivered by pump typically require 2 to 4 hours to fully correct an acute hyperglycemic episode, and sometimes multiple correction doses are needed to normalize the blood glucose level. This can be frustrating for patients, particularly when a correction bolus is necessary in addition to a meal bolus; frequently, patients must wait for the correction bolus to take effect and delay eating until the blood glucose has begun to normalize to avoid severe postprandial hyperglycemia. There is consequently an unmet need in insulin delivery, and in particular in CSII, for an insulin which can correct a hyperglycemic episode more rapidly than is currently possible with rapid-acting insulin analogues. Faster insulin aspart (Fiasp) is a novel formulation of insulin aspart with an accelerated time-action profile which results in twice the exposure to insulin and 74% greater insulin action within the first 30 minutes after injection compared to conventional insulin aspart. This results in twice-as-fast onset of appearance in the bloodstream (4 vs. 9 min compared to conventional insulin aspart) which has been demonstrated to reduce postprandial glucose levels in patients with type 1 DM using CSII. Theoretically, this faster insulin action would be useful in correction dosing during acute episodes of hyperglycemia to normalize the blood glucose level more rapidly than is currently possible with conventional insulin aspart (NovoLog). Many patients with type 1 DM using CSII now also use continuous glucose monitoring (CGM) for making insulin dosing decisions. Currently the FDA has approved 2 CGM systems for nonadjunctive use in bolus insulin dose calculations. Only one of these systems, the Dexcom, reads continuously to the patient and has alarms to warn of impending episodes of hyper- or hypoglycemia, and this is the system used most commonly by patients with type 1 DM using open-loop CSII. Patients now incorporate the Dexcom trend arrow, which depicts the rate and direction of glucose change, into the correction dose calculation, and recommendations on how to incorporate CGM information into correction dose calculations have recently been updated based on an expert consensus report. However, these guidelines were created for use with rapid acting insulin analogues. How they might need to be modified for use with Fiasp (the first and only ultra-rapid insulin analogue) is not known. The purpose of this investigator-initiated trial is to compare the efficacy in terms of time to recovery from hyperglycemia as measured by time to arrest of hyperglycemic excursion (glucose plateau point, primary endpoint) and return to premeal glucose target if feasible (secondary endpoint) between Fiasp and conventional insulin aspart when used as a correction bolus. These endpoints will be determined by CGM (Dexcom) from data exported from the Dexcom Clarity program. Study hypothesis: Compared to conventional insulin aspart, Fiasp will correct hyperglycemia (defined as arrest of rise of blood glucose, following correction bolus, ie, GPP ) faster than conventional insulin aspart in subjects with type 1 DM using CSII.

Interventions

DRUGFaster Insulin Aspart (Fiasp®)

Subjects will be randomized either to use Fiasp or conventional insulin aspart in CSII. CSII settings (basal, bolus, and correction factors) will be optimized using a meal challenge for a 2-week run in period followed by a 10-week period of CSII use with the assigned insulin. After a 12-week maintenance period, each group will cross over to the other insulin (conventional insulin aspart or Fiasp) by CSII for a second 2-week optimization period followed by a 10-week treatment period.

Sponsors

Mountain Diabetes and Endocrine Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Masking description

This is an open-label crossover trial. Subjects will be randomized to treatment sequence (Fiasp then NovoLog or NovoLog then Fiasp), each for a 12-week treatment period, by CSII. Randomization sequence will be determined by computerized randomization program. All patients will receive both treatments unless they drop out. Dropouts are unlikely since the participants are all regular continuing patients of the site's clinical practice.

Intervention model description

This is a 25-week open-label prospective single center 2 arm crossover trial consisting of a CSII settings (basal, bolus, and correction factors) will be optimized for a 2-week run in period followed by a 10-week period of CSII use with the assigned insulin. After a 12-week maintenance period, each group will cross over to the other insulin (conventional insulin aspart or Fiasp) by CSII for a second 2-week optimization period followed by a 10-week treatment period.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male and female patients \> 18 years of age * Type 1 DM of \> 1 year duration * Use of any open loop insulin pump, Tandem T-Slim with Basal IQ, Insulet Omnipod Dash, or any other investigator-approved insulin pumps with Dexcom CGM G5, G6, or newer version for \> 6 months * Good baseline glycemic control (HbA1c \< 7.5%; low risk of hypoglycemia by CGM as defined by Dexcom Clarity report) * No episodes of severe hypoglycemia in the previous 3 months * Pump download shows regular meal bolusing, accurate carbohydrate counting ability, and willingness to use exercise markers in Dexcom * CGM download shows regular use (\>85% of time) and regular calibration if using G5 sensor (G6 requires no calibration) * Females using adequate contraception

Exclusion criteria

* Use of CGM other than Dexcom G5 or G6 or a newer Dexcom CGM version * Suboptimal baseline glycemic control (HbA1c \> 7.5%) * Pump or CGM download shows suboptimal use of devices (lack of meal boluses, frequent overrides of pump, excessive pump suspension, inadequate calibration or inconsistent usage of CGM) * Serious comorbidities including CVD with recent event, actively treated malignancy, renal dysfunction with eGFR \< 45 ml/min, or any other condition which in the opinion of the investigator would preclude subject's ability to participate in trial * Females unwilling to use contraception, planning pregnancy or breastfeeding * Use of any other glucose-lowering agents than insulin * Hypersensitivity to insulin aspart or one of the excipients in faster insulin aspart * Known diabetic gastroparesis

Design outcomes

Primary

MeasureTime frameDescription
Time to stabilization of rising blood sugar by CGM after correction bolus2 weeksTime (in minutes) to stabilization of rising blood sugar (GPP) by CGM after correction bolus during the final 2 week maintenance period. Two categories of correction dose will be analyzed: 1) those following an isolated correction dose (taken independently of a meal dose), and 2) those taken as part of a combination bolus with a meal dose.

Secondary

MeasureTime frameDescription
Change in Insulin Sensitivity Factor25 weeksChange in Insulin Sensitivity Factor, if any, required for hypoglycemia prevention using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report
Change in Insulin On Board25 weeksChange in Insulin On Board, if any, required for prevention of late hyperglycemia using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report
GlycoMark differences between arms25 weeksGlycoMark (1,5 anhydroglucitol, a marker of postprandial glucose excursion) during use of each insulin.
Incidence of early hypoglycemia25 weeksIncidence of early hypoglycemia (Blood glucose \< 54 mg/dl within 1 and 2 hours) following correction bolus with each insulin (Key Safety Endpoint)
Percent time spent in target range, hyperglycemic range, and hypoglycemic range4 weeksPercent time spent in target range, hyperglycemic range and hypoglycemic range by Continuous Glucose Monitoring (CGM) on each insulin during the final 2 weeks of each treatment period. Target ranges include 70-180 mg/dL. Hyperglycemia ranges to be captured will include Category 1: 181-250 mg/dL and Category 2: above 250 mg/dL. Hypoglycemia ranges to be captured include Category 1: 69-54 mg/dL and Category 2: below 54 mg/dL.
Standard deviation differences between arms4 weeksStandard deviation of mean blood glucose as determined by CGM on each insulin
Treatment related impact measures between arms6 weeksTreatment related impact measures on each insulin using TRIM D questionnaire
HbA1c differences between arms25 weeksHbA1c during use of each insulin

Countries

United States

Contacts

Primary ContactWendy S Lane, MD
mountaindiabetes@msn.com8286849588
Backup ContactMelinda L Buford, RN, BSN
mbuford@mdecresearch.com8286849588

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026