Skip to content

EvaLuate EndoVascular Treatment of Acutely Ruptured Shallow Intradural Aneurysms With the Pipeline™ Flex Embolization Device With Shield TEchnology™ (ELEVATE)

EvaLuate EndoVascular Treatment of Acutely Ruptured Shallow Intradural Aneurysms With the Pipeline™ Flex Embolization Device With Shield TEchnology™ (ELEVATE)

Status
Terminated
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04391803
Acronym
ELEVATE
Enrollment
25
Registered
2020-05-18
Start date
2022-05-06
Completion date
2025-10-20
Last updated
2026-01-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Aneurysm, Ruptured Aneurysm

Keywords

wide neck, intradural aneurysm

Brief summary

The purpose of the study is to assess the safety and effectiveness of the Pipeline™ Flex Embolization Device with Shield Technology™ in the treatment with acutely ruptured intracranial aneurysms.

Detailed description

The ELEVATE study is a prospective, multi-center, single-arm trial of the Pipeline™ Shield Device for the treatment of adults with acutely ruptured intracranial aneurysms. The primary objective of the ELEVATE study is to assess the safety and effectiveness of treatment with the Pipeline™ Shield Device of acutely ruptured intracranial aneurysms that are not amenable for clipping and coiling.

Interventions

The Pipeline™ Flex Embolization Device with Shield Technology™ is intended for endovascular treatment of adults with intracranial acutely ruptured aneurysms not amenable to clipping and coiling.

Sponsors

Medtronic Neurovascular Clinical Affairs
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
22 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Subject has a previously untreated, wide neck, side-wall, intradural aneurysm that is deemed unfavorable for both surgical clipping and endovascular coiling, as confirmed on DSA. 2. Subject has a ruptured intracranial aneurysm with vessel diameter suitable for treatment with the study device. 3. Subject is ≥ 22 and ≤ 80 years of age. 4. Subject has an acutely ruptured aneurysm with Hunt and Hess Scale 1, 2 or 3. 5. Subject or subject's Legally Authorized Representative (LAR) has provided written informed consent.

Exclusion criteria

1. Subject's vessel characteristics preclude safe endovascular access to the aneurysm to treat with the Pipeline™ Shield Device. 2. Subject has aneurysm vessel characteristics that would preclude the device from fully conforming to the parent vessel to reduce any risk of embolic complications, retreatment, or device movement. 3. Subject has true bifurcation or aneurysms with vessels that cannot be separated from the fundus with placement of the study device. 4. Subject with intraparenchymal hemorrhage. 5. Subject is unable to undergo nasogastric/orogastric tube placement prior to device placement. 6. Subject has a pre-morbid mRS \>2. 7. Subject requires treatment of another aneurysm (with another treatment modality) within the affected territory of the target aneurysm. 8. Subject has a target ruptured aneurysm that is thought to be mycotic, including those caused by left atrial myxoma, or subject has an active systemic bacterial infection. 9. Subject with a requirement for continuous anti-coagulation. 10. Subject has a malignant brain tumor or vascular malformation (e.g. arteriovenous malformation). 11. Subject's target ruptured aneurysm has not been determined by the treating physician to be the source of SAH. 12. Subject with known allergy to platinum or cobalt chromium alloy (including the major elements platinum, cobalt, chromium, nickel or molybdenum). 13. Subject has a known hypersensitivity to ticagrelor or aspirin. 14. Subject is unable to undergo DSA or DSA is determined unsuitable by the treating physician. 15. Subject has a serious or life-threatening comorbidity that could confound study results. 16. Subject is at high risk of noncompliance per treating physician due to reasons including but not limited to a history of substance abuse. 17. Subject is unable to complete scheduled follow-up assessments due to comorbidities, geographical limitations, or a life expectancy of less than 24 months. 18. Subject is pregnant, or breastfeeding at the time of admission or plans to become pregnant during their participation in the study. 19. Subject is participating in another clinical study at the time of enrollment. 20. Presumed septic embolus, or suspicion of microbial superinfection. 21. Subject with a known COVID-19 viral infection, confirmed by testing. 22. Subject in whom a pre-existing stent is in place in the parent artery at target aneurysm location.

Design outcomes

Primary

MeasureTime frameDescription
Incidence of neurological death or disabling stroke post-procedure.at 365-dayDisabling stroke is defined as any post-procedural ischemic or hemorrhagic event that results in poor functional outcome (i.e. mRS ≥ 3 points) assessed at 90 days post stroke event.
Incidence of complete angiographic occlusion without significant stenosis, and no rebleeding or retreatment of the target aneurysmat 365-dayOcclusion is measured by the Raymond Roy Scale. Significant stenosis is classified as ≤ 50%.

Secondary

MeasureTime frameDescription
Incidence of rebleed of target aneurysmthrough 180-day and 365-day post procedure
Incidence of neurological hemorrhagic serious adverse eventsthrough 180-day and 365-day post procedure
Incidence of ipsilateral major stroke or neurological death post-procedure after 30 daysthrough 180-day and 365-day post procedure
Incidence of any ipsilateral stroke post-procedure after 30 daysthrough 180-day and 365-day post procedure
Good clinical outcome (modified Rankin Scale (mRS) 0-2)at 30-day, 180-day and 365-day post procedureScale for measuring general neurologic function: 0- No symptoms at all 1. No significant disability despite symptoms; able to carry out all usual duties and activities 2. Slight disability; unable to carry out all previous activities, but able to look after own affairs without assistance 3. Moderate disability; requiring some help, but able to walk without assistance 4. Moderately severe disability; unable to walk without assistance and unable to attend to own bodily needs without assistance 5. Severe disability; bedridden, incontinent and requiring constant nursing care and attention 6. Dead
Incidence of parent artery thrombosisthrough 365-day post procedure
Incidence of in-construct stenosis > 50%through 365-day post procedure
Incidence of retreatmentthrough 180-day and 365-day post procedure
Incidence of peri-/post-procedural serious adverse events related to the device, procedure or antiplatelet therapythrough 180-day and 365-day post procedure
Incidence of complete angiographic occlusion without significant stenosis (≤ 50%), and no rebleeding or retreatment of the target aneurysmthrough 365-day post procedure
Incidence of neurological death or disabling strokethrough 365-day post procedure
Pipeline™ Flex Device Deployment Success RateDay 0 During Procedure

Countries

United States

Contacts

PRINCIPAL_INVESTIGATORDavid Fiorella, MD

Stony Brook University Hospital

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026