Skip to content

Assessment of the Relationship Between Cerebral Blood Flow and Heart Rate

Assessment of the Relationship Between Cerebral Blood Flow and Heart Rate: An Electrophysiology Based Study

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04391465
Enrollment
20
Registered
2020-05-18
Start date
2021-08-11
Completion date
2027-12-01
Last updated
2026-05-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cerebrovascular Circulation, Physiology

Keywords

Cerebral Blood Flow

Brief summary

The investigators will seek to determine the relationship between heart rate and middle cerebral artery (MCA) cerebral blood flow (CBF), as well as better understand the hemodynamic determinants of MCA CBF velocity. In order to manipulate heart rate, the investigators will recruit patients already scheduled for clinically indicated elective electrophysiological studies, where temporary pacing catheters placed in the right atrium can be used to artificially pace the heart at controlled rates. MCA CBF will be measured by transcranial Doppler ultrasound.

Detailed description

Background: Cerebral blood flow (CBF) is maintained at a relatively constant level by multiple overlapping auto-regulatory systems over a wide range of blood pressures. This ensures adequate oxygen delivery to the brain and is critical to ongoing brain function and consciousness. Patients with reduced CBF experience symptoms of presyncope (e.g. lightheadedness, dizziness, trouble concentrating) and may faint. In patients with postural tachycardia syndrome (POTS), these orthostatic symptoms are a chronic issue, but the underlying pathophysiology is poorly understood - there is both evidence for and against impaired cerebral auto-regulation in POTS patients. Previous studies have demonstrated that increased cardiac output improves CBF independent of mean blood pressure. This is of particular interest in POTS patients, who display reduced cardiac output both during rest and orthostasis. This is due in part smaller heart size and reduced blood volume, which necessitate high heart rates to maintain cardiac output. The relationship between cardiac output and CBF has not been studied in POTS patients. Given the characteristic orthostatic tachycardia seen in these patients, the effects of heart rate on CBF are also of interest. The relationship between heart rate and CBF, to our knowledge, has not been studied. The chronic orthostatic symptoms in POTS patients are largely unexplained, but contributed centrally to significantly reduced quality of life. These symptoms are thought to be caused in part by alterations in CBF. While POTS does not have a "cure", alleviation of orthostatic symptoms would likely improve patients' ability to engage with activities of daily living and may reduce overall disease burden. Gaining an improved understanding of the hemodynamic determinants of CBF is essential to achieving this goal. Objectives: To assess the relationship between heart rate and middle cerebral artery (MCA) CBF. Additionally, to better understand the hemodynamic determinants of MCA CBF velocity by examining the relationships between heart rate, stroke volume, pulse pressure, and MCA CBF velocity. Methods: This will be an open-label, single group study in otherwise healthy patients scheduled for elective electrophysiology studies prior to planned ablations for supraventricular tachycardia. The study will take place with the participant supine on the electrophysiology laboratory procedure table, with a temporary pacing catheter already placed in the high right atrium. Prior to beginning the study protocol, the participant will be instrumented with non-invasive (a) skin electrodes to continuously monitor heart rate and record an electrocardiogram; (b) a volume-clamp finger cuff to monitor beat-to-beat blood pressure, calibrated with intermittent brachial cuff measurements; and (c) a transcranial Doppler System to record CBF velocity. Estimates of stroke volume, cardiac output, and systemic vascular resistance will be obtained using Modelflow-based waveform analysis of the continuous blood pressure waveform. A clinically standard sinus node recovery time (SNRT) protocol will be performed whilst collecting CBF and hemodynamic responses. Pacing will occur at 600 ms (100 bpm), 500 ms (120 bpm), 400 ms (150 bpm), and 350 ms (171 bpm) cycles for 60 seconds each, with a rest period of at least 60 seconds between pacing runs. After these pacing runs, the study data collection will be complete and the extra blood pressure cuffs and transcranial doppler probes will be removed from the participant so that the clinical electrophysiology study may continue as planned. The investigators estimate that this study will add no more than 10-15 minutes to the overall procedure time. In this exploratory "proof of concept" study, the investigators plan to enrol 20 participants.

Interventions

OTHERElectrophysiological Pacing

Assess the MCA CBF velocity response at different paced heart rates.

Sponsors

University of Calgary
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* Male or female * Age 18-70 years, inclusive * Scheduled for clinically indicated elective electrophysiological studies where temporary pacing catheters are being placed in the right atrium * Left ventricular ejection fraction ≥50% * Able and willing to provide informed consent * Able to travel to the Cardiac Electrophysiology Laboratory at the Foothills Medical Centre, Calgary, Alberta, Canada

Exclusion criteria

* Unable or unwilling to provide informed consent * Other factors which in the investigator's opinion would prevent the participant from completing the protocol

Design outcomes

Primary

MeasureTime frameDescription
Change in MCA CBF velocity in response to high right atrial pacing at 400 ms (150 bpm) relative to baseline while in the supine positionAfter 1 minute of pacing at 400 ms (150 bpm)Compare the MCA CBF velocity at the participant's own baseline sinus rhythm (\<100 bpm) and during pacing at 400 ms (150 bpm)

Secondary

MeasureTime frameDescription
Change in MCA CBF velocity in response to high right atrial pacing at 600 ms (100 bpm) relative to baseline while in the supine positionAfter 1 minute of pacing at 600 ms (100 bpm)Compare the MCA CBF velocity at the participant's own baseline sinus rhythm (\<100 bpm) and during pacing at 600 ms (100 bpm)
Change in MCA CBF velocity in response to high right atrial pacing at 350 ms (171 bpm) relative to baseline while in the supine positionAfter 1 minute of pacing at 350 ms (171 bpm)Compare the MCA CBF velocity at the participant's own baseline sinus rhythm (\<100 bpm) and during pacing at 350 ms (171 bpm)
Change in MCA CBF velocity in response to high right atrial pacing at 400 ms (150 bpm) relative to pacing at the lowest rate (100 bpm) while in the supine position10 minute electrophysiological pacing protocolCompare the MCA CBF velocity during pacing at 600 ms (100 bpm) and during pacing at 400 ms (150 bpm)
Change in MCA CBF velocity in response to high right atrial pacing at 350 ms (171 bpm) relative to pacing at the lowest rate (100 bpm) while in the supine position10 minute electrophysiological pacing protocolCompare the MCA CBF velocity during pacing at 600 ms (100 bpm) and during pacing at 350 ms (171 bpm)
Change in stroke volume in response to high right atrial pacing at 400 ms (150 bpm) relative to baseline while in the supine position10 minute electrophysiological pacing protocolCompare the stroke volume at the participant's own baseline sinus rhythm (\<100 bpm) and during pacing at 400 ms (150 bpm)
Change in cardiac output in response to high right atrial pacing at 400 ms (150 bpm) relative to baseline while in the supine position10 minute electrophysiological pacing protocolCompare the cardiac output at the participant's own baseline sinus rhythm (\<100 bpm) and during pacing at 400 ms (150 bpm)
Change in pulse pressure in response to high right atrial pacing at 400 ms (150 bpm) relative to baseline while in the supine position10 minute electrophysiological pacing protocolCompare the pulse pressure at the participant's own baseline sinus rhythm (\<100 bpm) and during pacing at 400 ms (150 bpm)

Countries

Canada

Contacts

CONTACTSatish R Raj, MD MSCI
satish.raj@ucalgary.ca403-210-6152
PRINCIPAL_INVESTIGATORSatish R Raj, MD MSCI

University of Calgary

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 8, 2026