Skip to content

Comminuted Fractures of the Midshaft of the Tibia; (Interlocking Nail +/- Blocking Screws or Locked Plating With Predicted Distribution of Locking Screws) Choice Based on Finite Element Analysis Correlated With Clinical Outcome and Union.

Finite Element Analysis for Comminuted Fractures of the Midshaft of the Tibia; (Interlocking Nail +/- Blocking Screws or Locked Plating With Predicted Distribution of Locking Screws)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04388462
Acronym
Finite Element
Enrollment
20
Registered
2020-05-14
Start date
2018-01-05
Completion date
2020-05-02
Last updated
2020-05-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Comminuted Fracture Tibia

Keywords

Comminuted fracture, Finite element analysis, Tibia

Brief summary

study is to assess the clinical and radiological results of Comminuted fractures of the midshaft of the tibia; treated with interlocking nail +/- blocking screws or locked plating with predicted distribution of locking screws, choice based on finite element analysis correlated with clinical outcome and union.

Detailed description

FE analyses will be performed using the finite element code COSMOS/M. The three-dimensional lower leg FE model (LL FE model) will be used included the tibia and the fibula. The bony structures will be generated by segmentation of a data set of computed tomographies from the Visible Human Project. Analysis of data regarding clinical outcomes and radiological assessment of healing rate and union

Interventions

OTHERFinite element analysis

Biomechanical study to describe micromotion

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
25 Years to 45 Years
Healthy volunteers
No

Inclusion criteria

1. patients with closed comminuted fractures of the midshaft of the tibia 2. patients with age ranging from 25 to 45 years old

Exclusion criteria

* 1- Simple fractures of the midshaft of the tibia. 2- patients with open comminuted fractures of the midshaft of the tibia. 3- critical and ICU patients. 4- patients with ipsilateral lower limb fractures.

Design outcomes

Primary

MeasureTime frameDescription
Healing of the fracture3 monthradiographic evaluation of union rate and clinical outcomes
Tibia Pain3 monthVisual analogue scale

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026