Skip to content

The Use of the Hem-o-lok Clip in Appendectomy: Single or Double?

Comparison of Single and Double Hem-o-log Clips in Laparoscopic Appendectomy

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04387370
Enrollment
120
Registered
2020-05-13
Start date
2020-09-01
Completion date
2023-04-18
Last updated
2023-04-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Appendicitis

Keywords

Laparoscopic appendectomy, Hem-o-lok clip, stump closure

Brief summary

Stump safety is provided by different methods in laparoscopic appendectomy. Stapler use, binding with endoloop and nonabsorbable clip are the most common methods. Although the stapler is safe, it creates a significant cost increase. In connecting with the endoloop, the learning curve and surgical time are longer. Nonabsorbable clip application which has been used recently; Urethra was also used in appendectomy after its safety has been proven by large studies to close cystic ducts and vascular structures. Its advantages such as low cost, no need for a learning curve and shortening the surgical time have increased the frequency of use.In this prospective observational study; It will be aimed to investigate the effects of stump closure methods applied in laparoscopic appendectomy on short-term clinical results. In addition, the factors that determine the surgeon's stump closure method and cost results will be tried to be determined.

Detailed description

Detailed explanation will be made later if necessary.

Interventions

None listed

Sponsors

Ulas Aday
Lead SponsorOTHER_GOV

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

* diagnosis of acute appendicitis * Performing laparoscopic surgery * Patients with an ASA score of I-II-III

Exclusion criteria

* Appendectomies with the patient's refusal to participate in the study * Open surgery * Primary pathology without appendicitis

Design outcomes

Primary

MeasureTime frameDescription
Is it safe to close the appendix stump with a single hem-o-lok clip?one yearComplications of patients using single and double clips will be compared according to Clavien-Dindo scoring system.

Secondary

MeasureTime frameDescription
The effect of single and double hem-o-lok clips on cost in laparoscopic appendectomyone weekWith the use of a single clip, surgery costs are expected to be less in dollars.Student's t-test will be used for cost analysis.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 8, 2026