Skip to content

Strategies for Asymmetrical Triacetate Dialyzer Heparin-Free Effective Hemodialysis

Strategies for Asymmetrical Triacetate Dialyzer

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04381234
Acronym
SAFE
Enrollment
20
Registered
2020-05-08
Start date
2018-01-06
Completion date
2020-05-05
Last updated
2020-05-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hemodialysis Complication

Keywords

anticoagulation, clotting, hemodialysis, hemodiafiltration, citrate

Brief summary

Not all dialysis patients tolerate heparin anticoagulation. Heparin should be avoided in patients at high risk of bleeding. Strategies include saline infusion, citrate-containing dialysate, regional citrate anticoagulation and heparin-coated membranes. We recently studied the combination of a heparin-coated membrane and citrate-containing dialysate, with a success rate of 94% . Although this combination resulted in low rates of clotting, heparin-coated membranes are not ubiquitously available. The quest for easy to perform, safe and affordable heparin-free dialysis is on. Asymmetric cellulose triacetate (ATA) dialyzers have a low degree of platelet contact activation and might be an alternative to heparin-coated dialyzers. This is a phase II pilot study in maintenance dialysis patients. Study design is a two-arm open-label cross-over study. In Arm 1, patients were dialyzed using a 1.9 m2 ATA membrane (Solacea™-19H, Nipro Corp., Japan) in combination with citrate (1 mM) containing dialysate. In Arm 2, patients were dialyzed with the same 1.9 m2 ATA membrane, in combination with high volume predilution hemodiafiltration. The primary endpoint was the success rate to complete 4 hours of hemodialysis without preterm clotting.

Detailed description

Anticoagulation is one of the supporting pillars of chronic hemodialysis (HD). The optimal anticoagulant regimen provides full anticoagulation of the extracorporeal circuit with minimal systemic effects and comes at an affordable cost. Unfractionated heparin (UFH) has been the standard of care for many years. In several countries, UFH has gradually been replaced by low molecular weight heparins (LMWH). LMWH are easy to use as they can be administered as a bolus injection and reduce membrane fibrin and platelet deposition. Both UFH and LMWH provide adequate anticoagulation of the extracorporeal circuit, at the price of systemic anticoagulation. Apart from bleeding, the administration of unfractionated heparins has also been associated with dyslipidemia, hypoaldosteronism and hyperkalemia, thrombopenia, osteoporosis, pruritus, and hypersensitivity reactions. Several alternative anticoagulation regimens have been proposed including saline infusion, heparin coating of the dialyzer membrane as well as regional citrate anticoagulation. Regional citrate anticoagulation is performed by infusing citrate into the arterial line of the dialysis tubing to reduce ionized calcium concentrations in order to minimize propagation of the coagulation cascade. Ionized calcium concentrations are restored by calcium supplementation prior to reinfusion of the blood into the patient. The HepZero study suggested that regional citrate anticoagulation is superior to heparin-coated polyacrylonitrile dialyzers (AN69ST; Nephral 300ST, Gambro) and resulted in in significantly greater instantaneous urea nitrogen clearance. While generally safe and adequate, regional citrate anticoagulation requires additional actions during preparatory phase (preparation of citrate and calcium infusion pumps) as well as during the treatment (measurement of ionized calcium). Recently, acetate-free citrate-containing dialysate concentrates were introduced into clinical practice. Besides the advantages of acetate-free dialysate, this provides a modest local anticoagulant effect inside the dialyzer. Citrate-containing dialysate allowed to reduce heparin dose while maintaining extracorporeal circuit patency and dialyzer clearance. Recently, citrate-containing dialysate and a heparin-coated dialyzer were combined. In one study, non-inferiority to regional citrate anticoagulation was demonstrated The abovementioned studies demonstrate that hemodialysis without systemic heparinization is feasible. However, such procedures are more cumbersome, require more manpower, additional biochemical testing and/ or more expensive consumables. The aim of the current study is to test two different strategies for systemic heparin-free dialysis with an asymmetrical tri-acetate hemodialyzer. Trial objectives To evaluate the feasability, safety and adequacy of systemic heparin-free dialysis using an asymmetrical tri-acetate dialyzer membrane, with or without the combination with citrate containing dialysate. The main objective of the study is to test efficacy of the two study interventions to perform standard duration (i.e. 4 hours) hemodialysis without interruption due to clotting phenomena and without the use of heparin or low molecular weight heparins.

Interventions

DEVICEdialyzer

Asymmetric triacetate dialyzer

COMBINATION_PRODUCThemodialysis with citrate-containing dialysate

acetate-free dialysate

OTHERpredilution hemodiafiltration

predilution hemodiafiltration

Sponsors

NIPRO
CollaboratorUNKNOWN
Universitaire Ziekenhuizen KU Leuven
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

open-label sequential cross-over study

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients age 18 years, or over. No maximum age is defined. * Providing signed and dated informed consent (ICF) * Maintenance dialysis (\> 3 months of hemodialysis) * 'Standard' dialysis regimen (three dialysis sessions / week, dialysis duration 4 hours) * Hemodynamic stability during 4 weeks preceding study period. Hemodynamic instability is defined as any episode of low blood pressure (asymptomatic or symptomatic requiring intervention (bolus fluid infusion, temporarily withholding or reducing ultrafiltration, preterm termination of dialysis session, resuscitation) * Hemoglobin 9 - 12 g/dl.

Exclusion criteria

* Any known medical disorder favoring either bleeding or clotting (e.g. atypical hemolytic uremic syndrome (aHUS), antiphospholipid syndrome, idiopathic thrombocytopenic purpura (ITP), paroxysmal nocturnal hemoglobinuria (PNH)) * Treatment with a vitamin K antagonist * Treatment with any one of the NOACs (apixaban, rivaroxaban, edoxaban, dabigatran) * High risk of bleeding according to the criteria of Swartz (12). * Patients with a known allergic reaction to asymmetric triacetate * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
clinical patency of the hemodialysis extracorporeal circuit4 hoursclotting of the extracorporeal circuit

Secondary

MeasureTime frameDescription
Clotting of dialyser4 hoursSemi-quantitative clotting score
dialysis adequacy4hourssingle pool Kt/V
Reduction ratio uremic retention solutes4 hoursratio describing the change in serum concentration over the concentration at the beginning of the dialysis session

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026