Skip to content

The Use of the Transient Elastography Paediatric Probe, Compared to the M Probe, Indirect Biomarkers and Histology

Special Considerations for the Use of the Transient Elastography Paediatric Probe, Compared to the Standard M Probe, Indirect Serological Markers and Histology

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04380493
Enrollment
141
Registered
2020-05-08
Start date
2015-05-31
Completion date
2019-12-31
Last updated
2020-05-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Liver Disease, Elastography, Fibrosis, Liver, Pediatrics

Keywords

Elastography, liver biopsy, biopsy, indirect biomarkers

Brief summary

The purpose of this study is to assess the reliability, reproducibility and accuracy of the paediatric probe of transient elastography in detecting liver fibrosis in children, besides its limitations and side effects. At the same time, to assess whether indirect fibrosis markers are a valid tool to detect absence or mild fibrosis in paediatric patients

Detailed description

A retrospective cohort study, including all patients younger than 18 years of age with chronic liver disease who underwent a transient elastography, was performed. The study was carried out in the joint Unit of Paediatric Complex Hepatology and Liver Transplant, encompassing two third level paediatric hospitals, between 2015 and 2019. The study protocol was approved by local ethic committee (identifier code: PR(AMI)147/2019) and informed consent was signed by patient's legal guardians and patients over 16 years old. Liver stiffness was assessed with FibroScan® (Echosens, France, model 502, class IIa, year 2010), which was performed by an experienced operator to avoid interobserver bias and in the same standardized conditions (fasting, decubitus position, right arm in maximal abduction, transducer placed over the right lobe). S probe (model 8; 5 MHz; diameter 5 mm), that measures depths ranging from 15-50 mm (S1: 15-40 mm; S2: 20-50 mm), was selected if chest circumference (CC) \< 75 cm (S1: ≤ 45 cm; S2: 45-75 cm). M probe (3.5 MHz; diameter 7 mm), measuring depths range 35-75mm, was used if CC ≥ 75 cm. Both probes met the calibration terms. Elastographic parameters studied were: stiffness (KPa), interquartile range (IQR) and success rate (SR). Adult-validated liver stiffness measurement ranges to classify the fibrosis degree were taken as a reference: F0-F1 (≤7.6 KPa), F2 (7.7-9.4 KPa), F3 (9.5-14 KPa) and F4 (\>14 KPa). The examination was successful when the median of at least 10 valid values, had a SR higher than 60% and with an IQR/LSM lower than 30%. The following sociodemographic, clinical and analytical data were collected: age, sex, underlying liver disease and analytical parameters (alanine aminotransferase (ALT) U/L, aspartate aminotransferase (AST) U/L, gamma glutamyl transferase (GGT) U/L, total bilirubin (mg/dl), cholesterol (mg/dl), platelets (109/L), prothrombin time (%)). The following liver fibrosis test Scores were calculated using the obtained data: * Fibrosis 4 Score (FIB-4) = Age (years) x AST (U/L) / platelets (109/L) x √ALT (U/L). * AST to Platelet Radio Index (APRI) = AST (upper normal limit) (UI/l)/ platelets x 109 x 100. Eighteen clinically indicated liver biopsies were performed and staged according METAVIR score (F0-F4). Blood test, fibrosis scores and biopsies were performed within 6 months of transient elastography. No clinical or analytical changes were observed during this period. The Faces Pain Scale was used for assessing pain severity. Statistical analysis: Kolmogorov-Smirnov test checked out if variables followed a normal distribution. Continuous variables are presented as mean ± standard deviation or median (interquartile range) and categorical variables as number of subjects and percentage. Correlation between continuous variables were calculated using Pearson's and Spearman's correlation coefficient. The variance's analysis (ANOVA) and the Kruskal Wallis test were used to compare qualitative with quantitative variables. Two-tailed p-Values of \<0.05 were considered as statistically significant. Sensitivity, specificity, positive predictive value and negative predictive value were calculated in the assessment of FIB-4 and APRI as a diagnostic test to detect absence or mild fibrosis (F0-F1), using the results obtained by TE as a reference. The statistical analyses were performed with SPSS software (v. 21, SPSS Inc., Chicago, IL, USA) and Prism (v. 7.04 GraphPad Software Inc.).

Interventions

DIAGNOSTIC_TESThepatic transient elastography using S probe and M probe

Sponsors

Hospital Vall d'Hebron
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 18 Years
Healthy volunteers
No

Inclusion criteria

* Patients younger than 18 years of age with chronic liver disease who underwent a transient elastography. * Parents / legal guardians and the patients themselves, if applicable, have read, understood and signed the informed consent of the study.

Exclusion criteria

* Patients who do not meet all the inclusion criteria for inclusion in the study protocol.

Design outcomes

Primary

MeasureTime frameDescription
Validation of FibroScan's® pediatric (S) probe in children4 yearsTo describe our experience with FibroScan's® pediatric (S) probe; its reliability, reproducibility, and accuracy in detecting fibrosis, as compared to M probe and histology, as well as its limitations and side effects

Secondary

MeasureTime frameDescription
Validation of indirect fibrosis markers4 yearsTo assess whether indirect fibrosis markers (APRI and FIB-4) are a valid tool to detect absence or mild fibrosis in paediatric patients

Countries

Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026