Skip to content

Hemodynamic Effects of Delayed Umbilical Cord Clamping in Full-term Newborns

Hemodynamic Effects of Delayed Umbilical Cord Clamping in Full-term Newborns

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04358822
Enrollment
68
Registered
2020-04-24
Start date
2020-01-21
Completion date
2020-03-31
Last updated
2020-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Output, High, Cardiac Output, Low

Brief summary

The sequence of events at the time of delivery includes delivery of the infant, clamping of the umbilical cord, and lastly delivery of the placenta. There are some benefits for delayed cord clamping. This study aims to compare the effects of two different duration of delayed cord clamping. Infants will be randomized into two groups based on the duration of delayed cord clamping: 30 seconds vs 120 seconds. Different hemodynamic effects will be measured in each group at different time intervals. The hypothesis of the study is that delayed cord clamping for 120 seconds is associated with better cardiac output and with other hemodynamic advantages.

Detailed description

The study will include full term infants delivered via cesarean section. Written informed consent for participation in the study will be obtained from parents prior to delivery. Newborns will be randomly assigned into two groups according to the duration of cord clamping: Group 1: the cord will be clamped at 30 seconds, and Group 2: the cord will be clamped at 120 seconds of life. Stopwatch will be started when infants buttocks (or head if breech) are delivered from the uterus. The time elapsed will be counted aloud by the investigator in 10-second intervals. During this time, the infant will be held in linen on the mothers legs. Care will be taken not to apply traction on the cord. Milking of the cord will not be allowed. Immediately after resuscitation, infants will be attached to the leads of the electrical cardiometry device. Device output will be imported at 5, 10, and 15 minutes after birth in both groups. A follow up measurement will be imported later at 24 hours of age. In addition, a peripheral blood sample will be obtained at 24 hours of age for assessment of hemoglobin, glucose and bilirubin concentrations. . The calculated sample size is 31 newborns in each group. This number will be adequate to detect an effect size of 10% in the mean cardiac output between the two groups with 95% confidence and 80% power. The study plans to recruit 34 infants in each group (10% attrition rate).

Interventions

PROCEDUREDelayed cord clamping

The umbilical cord will be clamped after specific time intervals

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
BASIC_SCIENCE
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Normal full term newborns ≥37 weeks gestational age * Both genders are included * Singleton * Delivered by elective cesarean section due to previous cesarean section, cephalo-pelvic disproportion, or mal-presentation * Successfully transitioned without need for respiratory or medication support

Exclusion criteria

* Neonates needing any active resuscitation * In-utero fetal distress * Suspected perinatal asphyxia * Major congenital malformations * Twin or multiple gestation * Intrauterine growth restriction * Placenta previa * Mothers with cardiac disorders

Design outcomes

Primary

MeasureTime frameDescription
Oxygen saturationat 15 minutesData imported from the electrical cardiometry device
Cardiac indexat 15 minutesData imported from the electrical cardiometry device
Index of contractilityat 15 minutesData imported from the electrical cardiometry device
Heart rateat 15 minutesData imported from the electrical cardiometry device
Cardiac outputat 15 minutesData imported from the electrical cardiometry device
Stroke volumeat 15 minutesData imported from the electrical cardiometry device

Secondary

MeasureTime frameDescription
Serum glucose concentrationAt 24 hoursBlood sample will be obtained an analyzed
Serum bilirubin concentrationAt 24 hoursBlood sample will be obtained an analyzed
Hemoglobin concentrationAt 24 hoursBlood sample will be obtained an analyzed

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026