Skip to content

Electromyographic and Acceleromyographic Monitoring in Restricted Arm Movement Surgical Setting

Electromyographic and Acceleromyographic Monitoring in Restricted Arm Movement Surgical Setting. A Prospective, Randomized Trial.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04352140
Enrollment
60
Registered
2020-04-20
Start date
2020-08-18
Completion date
2022-02-14
Last updated
2023-02-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Residual Neuromuscular Blockade

Keywords

Neuromuscular Blockade, Tetragraph, AMG, EMG

Brief summary

Researchers are comparing the ease of use and repeatability of the force vs electrical activity produced by a muscle after it has undergone nerve stimulation during a surgical procedure in which the patients' arm movement is restricted (placed under surgical drapes) in laparoscopic or robotic procedures.

Interventions

FDA approved neuromuscular transmission monitor capable of measuring the depth of neuromuscular block in anesthetized patients who received neuromuscular blocking agents. TetraGraph uses EMG to measure the muscle action potentials that are generated in response to electrical neurostimulation via skin electrodes.

DEVICEToFscan

ToFscan is a nerve stimulator module used for the measurement of neuromuscular transmission via accelerometry. ToFscan was developed by Drager Technologies, Canada, and it uses a three-dimensional piezoelectric sensor that attaches to the thumb via a hand adapter to measure acceleration in multiple planes (Murphy et al, 2018). Following simultaneous ulnar nerve stimulation on each arm, the response of the adductor pollicis will be measured

Sponsors

Mayo Clinic
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age \> or = 18 years old * Patients willing to participate and provide an informed consent * Patients undergoing an elective laparoscopic or robotic surgical procedure that requires use of NMBA agents administered intraoperatively.

Exclusion criteria

* Patients with disorders, such as stroke, carpal tunnel syndrome, broken wrist with nerve damage, Dupuytren contracture, or any similar wrist injury. * Patients with systemic neuromuscular diseases such as myasthenia gravis * Patients with significant organ dysfunction that can significantly affect pharmacokinetics of neuromuscular blocking and reversal agents, i.e., severe renal impairment or end-stage liver disease. * Patients having surgery that would involve prepping the arm or leg into the sterile field

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of Values Between Tetragraph and ToFscanUp to 1 hour postoperativelyThe number of subject's who's residual neuromuscular blockage units are the same on both the TetraGraph and the ToFscan

Secondary

MeasureTime frameDescription
Incidence of Residual Neuromuscular BlockadeUp to 1 hour postoperativelyNumber of patients with train of four ratio \< 0.9 after administration of reversal agent.

Countries

France, Hungary, United States

Participant flow

Participants by arm

ArmCount
Dominant Hand
Subject who received an elective surgical procedure had TetraGraph device lead placement on the dominant hand, ToFscan placed on non-dominant hand Tetragraph: FDA approved neuromuscular transmission monitor capable of measuring the depth of neuromuscular block in anesthetized patients who received neuromuscular blocking agents. TetraGraph uses EMG to measure the muscle action potentials that are generated in response to electrical neurostimulation via skin electrodes. ToFscan: ToFscan is a nerve stimulator module used for the measurement of neuromuscular transmission via accelerometry. ToFscan was developed by Drager Technologies, Canada, and it uses a three-dimensional piezoelectric sensor that attaches to the thumb via a hand adapter to measure acceleration in multiple planes (Murphy et al, 2018). Following simultaneous ulnar nerve stimulation on each arm, the response of the adductor pollicis will be measured
30
Non-dominant Hand
Subject who received an elective surgical procedure had TetraGraph device lead placement on the non-dominant hand, ToFscan placed on dominant hand Tetragraph: FDA approved neuromuscular transmission monitor capable of measuring the depth of neuromuscular block in anesthetized patients who received neuromuscular blocking agents. TetraGraph uses EMG to measure the muscle action potentials that are generated in response to electrical neurostimulation via skin electrodes. ToFscan: ToFscan is a nerve stimulator module used for the measurement of neuromuscular transmission via accelerometry. ToFscan was developed by Drager Technologies, Canada, and it uses a three-dimensional piezoelectric sensor that attaches to the thumb via a hand adapter to measure acceleration in multiple planes (Murphy et al, 2018). Following simultaneous ulnar nerve stimulation on each arm, the response of the adductor pollicis will be measured
30
Total60

Baseline characteristics

CharacteristicDominant HandNon-dominant HandTotal
Age, Continuous60.2 years
STANDARD_DEVIATION 12.49
60.6 years
STANDARD_DEVIATION 14.04
60.37 years
STANDARD_DEVIATION 13.18
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
2 Participants0 Participants2 Participants
Race (NIH/OMB)
Black or African American
0 Participants1 Participants1 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
28 Participants29 Participants57 Participants
Region of Enrollment
Hungary
15 participants15 participants30 participants
Region of Enrollment
United States
15 participants15 participants30 participants
Sex: Female, Male
Female
13 Participants12 Participants25 Participants
Sex: Female, Male
Male
17 Participants18 Participants35 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 300 / 30
other
Total, other adverse events
0 / 300 / 30
serious
Total, serious adverse events
0 / 300 / 30

Outcome results

Primary

Accuracy of Values Between Tetragraph and ToFscan

The number of subject's who's residual neuromuscular blockage units are the same on both the TetraGraph and the ToFscan

Time frame: Up to 1 hour postoperatively

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Dominant HandAccuracy of Values Between Tetragraph and ToFscan0 Participants
Non-dominant HandAccuracy of Values Between Tetragraph and ToFscan2 Participants
Secondary

Incidence of Residual Neuromuscular Blockade

Number of patients with train of four ratio \< 0.9 after administration of reversal agent.

Time frame: Up to 1 hour postoperatively

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Dominant HandIncidence of Residual Neuromuscular Blockade3 Participants
Non-dominant HandIncidence of Residual Neuromuscular Blockade2 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026