Skip to content

UCP (Ultrasound Cyclo Plasty) in the Treatment of Chinese Patients With Primary Open-angle Glaucoma

Observation on the Clinical Safety and Efficacy of UCP (Ultrasound Cyclo Plasty) in the Treatment of Chinese Patients With Primary Open-angle Glaucoma

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04321122
Enrollment
60
Registered
2020-03-25
Start date
2018-08-12
Completion date
2020-06-12
Last updated
2020-03-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma, Glaucoma, Primary Open Angle

Keywords

Primary open-angle glaucoma, UCP(ultrasound cyclo plasty), Efficacy and Safety

Brief summary

Traditional ciliary body photocoagulation treatment uses the photocoagulation of long-wavelength laser to destroy the ciliary body tissue that can produce aqueous humor. Therefore, it is a kind of palliative treatment which has proved efficacy but causes great pain to patients. The ultrasonic glaucoma treatment instrument produced by French EYE TECH CARE company is referred to as EyeOP1. It uses high-intensity focused ultrasound technique to make target part of the ciliary coagulative necrosis, reduce the production of aqueous humor and thereby lower the intraocular pressure. EyeOP1 is ergonomic and suitable for the human eye, making the treatment process more accurate, simple and fast.

Detailed description

1. Efficacy: 1. Main objective: (1)Assess the decrease in postoperative intraocular pressure from baseline and evaluate the final results (the percentage of patients whose conditions have significant improved and the variation of the percentage of median intraocular pressure. (2)Assess the amount of medication after surgery. 2. Secondary goals:(1) Compare median intraocular pressure with baseline at each postoperative follow-up and access the variation of median intraocular pressure from baseline at each postoperative follow-up. (2) Count the number of intraocular pressure lowering drugs at each postoperative follow-up. b.Safety: Investigate the incidence of all device-related(or procedure-related) adverse events during the study (intraoperative and postoperative follow-up).

Interventions

PROCEDUREultrasound cyclo plasty

The ultrasonic glaucoma treatment instrument produced by French EYE TECH CARE company is referred to as EyeOP1.It uses high-intensity focused ultrasound technique to make target part of the ciliary coagulative necrosis, reduce the production of aqueous humor and thereby lower the intraocular pressure. EyeOP1 is ergonomic and suitable for the human eye, making the treatment process more accurate, simple and fast.

Sponsors

Zhongshan Ophthalmic Center, Sun Yat-sen University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
Yes

Inclusion criteria

* The target eye was diagnosed as primary open-angle glaucoma; diagnostic criteria: IOP(intraocular pressure)≥ 21, open angle, typical glaucoma visual field and optic disc damage; * Patients treated with glaucoma medications cannot control intraocular pressure effectively; * Patients with 21mmHg ≤ IOP ≤ 30mmHg; * VA(visual acuity)≥HM(hand motions); * Patients that have failed conventional glaucoma surgery (trabeculectomy) or are not suitable for surgery; * Patients who have not received intraocular surgery or laser treatment 90 days before receiving HIFU; * Aged from 18 to 90 years old; * Sign informed consent and be willing to provide visit data;

Exclusion criteria

* Either eye have any infections two weeks before the surgery; * The target eye has history of ciliary surgery, intraocular or retrobulbar tumor; * The target eye is neovascular glaucoma; * The target eye is aphakic eye; * Anterior anatomical abnormalities cause scleral expansion or ciliary body ectopic; * Non-glaucoma intraocular diseases that affect intraocular pressure; * Within 30 days, the patient participated in or was simultaneously included in other clinical trials; * Patients during pregnancy or lactation; * Any systemic disease that may affect patient follow-up.

Design outcomes

Primary

MeasureTime frameDescription
IOP(intraocular pressure)6 months after surgeryTo evaluate the success rate of IOP control at 6 months after UCP(5mmHg≤IOP≤21mmHg, and at least 20% lower than the baseline)

Countries

China

Contacts

Primary ContactChengguo Zuo, M.D,Ph.D
chengguozuo@163.com: 020-66615461
Backup ContactJian Ge, M.D,Ph.D
gejian@mail.sysu.edu.cn020-66615461

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026