Skip to content

Robotic Exoskeleton Assisted Gait Post Stroke

Functional and Neurophysiological Effects of a Progressive Robot Assisted Gait Intervention Early Post Stroke

Status
Enrolling by invitation
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04309305
Acronym
RE-Assist
Enrollment
75
Registered
2020-03-16
Start date
2020-01-30
Completion date
2026-09-01
Last updated
2025-04-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

CVA, Gait, Hemiplegic

Brief summary

The current investigation takes advantage of both a progressive and adaptive assist-as-needed massed practice and time-sensitive neuroplasticity through exoskeleton assisted walking in order to induce greater recovery-oriented CNS plasticity and consequent gains in more independent walking.

Detailed description

The purpose of this research study is to assess whether using a wearable device, called the robotic exoskeleton (RE), can be helpful in improving recovery of walking in adults who have recently had a stroke. The study will compare the walking abilities of people who went through standard of care treatment after a stroke to those who used the robotic exoskeleton as part of their rehabilitation. This study will also look at the effects walking in the RE has on brain activity. The name of the robotic exoskeleton that is being used in this study is the EksoTM.

Interventions

DEVICEEksoGT™, Ekso Bionics, Berkley, CA, USA

The Robotic Exoskeleton is a device that will be strapped to the chest and legs and worn over the shoulders like a backpack that will assist in walking.

OTHERStandard of Care

Standard gait therapy provided by licensed physical therapists post stroke.

OTHERNo Intervention

Testing Only

Sponsors

Kessler Foundation
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* Stroke survivors \< 4 weeks from most recent stroke. * Age: 21- 80 years * Unilateral hemiparesis * Medical clearance by the Medical Director * Be able to physically fit into the exoskeleton device. * Have joint range of motion within normal functional limits for ambulation. * Have sufficient strength to use the hemiwalker, cane or walker (etc. assistive device) while wearing the RE. * Patient cognitive status and ability to communicate in English must be at a level consistent with that required to participate in standard motor rehabilitation, e.g. can follow directions. * Adequate cognitive function to give informed consent, understand the training, instructions, use investigational devices and give adequate feedback. * No history of injury or pathology to the unaffected limb. * physically fit within the RE: Height below 60 or above 76 and weight above 220 lbs.

Exclusion criteria

* Any medical issue that precludes full weight bearing and ambulation (e.g. orthopedic injuries, pain, severe spasticity). * Skin issues that would prevent wearing the device. * Pre-existing condition that caused exercise intolerance.(Documented uncontrolled hypertension, coronary artery disease, cardiac arrhythmia, or congestive heart failure) * Hospitalization for heart attack, heart surgery or acute heart failure within 3 months of enrollment in study. * Severe cognitive or psychiatric problems as well as incontinence might be contraindications to start training with a RE. * History of severe cardiac disease such as myocardial infarction, congestive heart failure * Uncontrolled seizure disorder. * Uncontrolled spasticity or joint contracture that would interfere with walking in the RE and limits normal ROM during ambulation with assistive devices. * Neuromuscular or neurological pathologies (e.g., Parkinson's disease, spinal cord injury, or traumatic brain injury with evidence of motor weakness and multiple sclerosis) that will interfere with neuromuscular function, ambulation, or limit the range of motion of the lower limbs * Orthopedic pathologies or history that will interfere with ambulation or limit the ROM of the lower limbs (e.g., knee replacement, fixed contractures, inflammation) * Any metal implants that are NOT MRI-compatible

Design outcomes

Primary

MeasureTime frameDescription
Functional Independence Measure (FIM) (aim 1)Change from Baseline FIM at 10 weeksa conventional assessment measure of motor function
Within-brain functional connectivity (aim 2)Change from Baseline Within-brain functional connectivity at 10 weeksfMRI connectivity between selected regions of interest within the sensorimotor and attention networks.
TMS recruitment curve slope (aim 3)Change from Baseline TMS recruitment curve slope at 10 weeksA recruitment curve created using measure of primary motor cortex Motor Evoked Potential (MEP) at several stimulation thresholds.
electroencephalogram (EEG) (aim 3)Change from Baseline EEG at 10 weeksa measure of brain activation at different phases of gait cycle (swing versus double support).
electromyography (EMG) (aim 3)Change from Baseline EMG at 10 weeksa measure of muscle activation (EMG signal) at different phases of gait cycle (swing versus double support).
10MWT (aims 1-3)Change from Baseline 10MWT at 10 weeks10 meters walking test to evaluate walking speedafter stroke and in response to the intervention.
6MWT (aims 1-3)Change from Baseline 6MWT at 10 weeks6 minutes walking test to evaluate endurancein connectivity after stroke and in response to the intervention.
TUG (aims 1-3)Change from Baseline TUG at 10 weekstime up and go (TUG) test
structural connectivity (aim 2)Change from Baseline structural connectivity at 10 weeksDiffusion Tensor Imaging (DTI) and fractal dimensions (FD) measures of structural connectivity

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026