Skip to content

Strength Measurement in Intrinsic Foot Muscles With Break and Make Tests

Comparison of Strength Measurement in Intrinsic Foot Muscles With Break and Make Tests Using a Hand-held Dynamometer in Healthy Young Subjects

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04307758
Enrollment
77
Registered
2020-03-13
Start date
2019-08-05
Completion date
2020-02-17
Last updated
2020-03-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Adults, Healthy

Keywords

Make and Break Test, Strength assessment, Hand held dynamometer, Intrinsic foot muscles

Brief summary

The human foot is a complex structure, which serves functions such as support and mobility. These functions are accomplished through the deformation of the arch, which is controlled by intrinsic and extrinsic foot muscles. The intrinsic muscles have an important role in dynamic stabilization of the foot due to their structurally short force levers and small diameters. There are many studies reporting that foot intrinsic muscle weakness is directly related to pathologies such as structural or functional toe deformities, pes planus, hallux valgus, plantar fasciitis .Therefore it is essential to evaluate the strength of these muscles in an objective and reliable way.

Detailed description

Two different methods are used in measuring muscle strength via a Hand Held Dynamometer; the break test and the make test . During these tests, the examiner and subject play opposite roles. During the make test, the subject applies maximal force against the examiner and the position is maintained by the examiner. During the break test, the subject holds the position of the muscle being evaluated and the examiner pushes until the subject's maximal force is overcome. In the two tests, force is applied differently; the dynamometer receives different amounts of force, and different results may be generated. Therefore, the aim of this study was to compare the reliability of intrinsic foot muscle strength assessment with break and make test in healthy young subjects.

Interventions

OTHERMuscle Strength Assesment-Make Test

For the make test, the examiner applies resistance in a fixed position and the person being tested exerts a maximum effort against the dynamometer and examiner. The examiner is only required to sustain an isometric contraction and read the highest value on an Hand Held Dynamometer.

OTHERMuscle Strength Assesment-Break Test

For the break test, the examiner applies resistance sufficient to overcome the maximum effort of the person being tested and cause the subject's joint to move in the opposite direction, which results in an eccentric contraction. During this test the limb must move at a constant velocity while the person being tested is asked to achieve a maximum contraction. In addition, the examiner must read the force output reading at the exact time the subject's limb begins to move from the Hand Held Dynamometer.

Sponsors

Gazi University
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 35 Years
Healthy volunteers
Yes

Inclusion criteria

* Sedentary individuals, * Category 1 and 2 according to the International Physical Activity Questionnaire * Body mass index between the ranges ≥18.5 - \<24.9

Exclusion criteria

* Any orthopedic or neurological disorder * Previous history of lower extremity surgery * Having low back pain * Having vestibular or visual system problems * Having hallux rigidus or limitus, having a hallux valgus angle over 15 degrees

Design outcomes

Primary

MeasureTime frameDescription
Foot intrinsic muscle strength with the make testOnce a day for two days.Reliability of the Make Test
Foot intrinsic muscle strength with the break testOnce a day for two days.Reliability of the Break test

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026