Skip to content

The Clinical Feasibilityof a Multi-modal Photoacoustic/Ultrasonic Imaging System in Rheumatoid Arthritis

The Clinical Feasibility and Added Value of a Multi-modal Photoacoustic/Ultrasonic Imaging System in the Evaluation of Rheumatoid Arthritis

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04297475
Enrollment
200
Registered
2020-03-05
Start date
2019-01-01
Completion date
2022-12-31
Last updated
2020-10-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Rheumatoid Arthritis, Ultrasonography

Keywords

rheumatoid arthritis, ultrasonography, multi-modal imaging, photoacoustic imaging

Brief summary

New type of imaging method is in demand clinically for early detection and treatment guiding of RA. Photoacoustic imaging (PAI), a hot spot in medical imaging society, which combines the merits of optical imaging and US and has a capacity in morphological, functional and molecular imaging, has shown potential in visualizing superficial organs, including small joints. The investigators developed a multi-modal photoacoustic/ultrasound (PA/US) imaging system, equipped with a handheld 3D PA/US probe, which wass able to provide 3D volume data of dual-wavelength PA imaging of small joints, in addition to real-time 2D PA/US imaging. The investigators plan to recruit RA patients in different disease conditions and healthy volunteers to receive the 2D and 3D PA/US examination on the 2nd and 3rd MCP, PIP joints and wrist joints using this imaging system, and to evaluate the potential clinical role of the imaging system in RA, and its added value to current imaging methods.

Detailed description

The multi-modal PA/US imaging system was built on a high-end commercial US platform, and allowed real-time imaging of grey-scale US imaging, Color-Doppler US (CDUS) imaging and dual-wavelength PA imaging. The PA/US images were acquired using a hand-held probe integrated optical devices and US transducers. 3D volume data of the selected joint of each participant was collected using an automatic scanning device after the dual-modal imaging. The investigators plan to recruit RA patients from the outpatient department of Rheumatology of our hospital, who have been diagnosed as RA by experienced rheumatologists. The patients and healthy volunteers will receive multi-modal imaging examinations using the novel imaging system. The MCP 2 and 3, PIP 2 and 3, and wrist of bilateral hand were chosen for the multi-modal imaging. Conventional US scanning of the joints, including grey-scale US, CDUS, and PDUS, will be carried out by an experienced US operator. Afterwards, 2D and 3D PA/US imaging will be implemented for each joint by the same operator. All of the imaging data will be analysed by the Matlab software.

Interventions

The multi-modal PA/US imaging system is equipped with a handheld 3D PA/US probe, and able to provide 3D volume data of dual-wavelength PA imaging of small joints, in addition to real-time 2D PA/US imaging.

Sponsors

Peking Union Medical College Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

The inclusion criteria 1. The patients were above 18 years-old; 2. The patients were diagnosed with RA according to the American College of Rheumatology (ACR) criteria, and the current clinical state was in-active or relapse; 3. The patients were consent to receive examinations of photoacoustic imaging. The

Exclusion criteria

1. The patients had mental disease or other severe diseases, and were not capable of receiving imaging examinations; 2. The patients had strong reaction to laser light.

Design outcomes

Primary

MeasureTime frameDescription
The PA scores of 50 participants with RA identified by the multi-modal imaging system are in accordance with clinical scoring3-6 monthsA total of 50 participants received semi-quantitatively measurement of PA signals by the imaging system using a 0-3 scoring system. Score 0 is no PA signals, which represents no detectable active inflammation on PA imaging. Score 1 means less than 3 bars of PA signals within the inflamed regions. Score 2 means multiple PA signals within less than half of the inflammatory lesions. And score 3 means abundant PA signals in over half of the lesions of RA synovium or tenosynovium, which may represent high inflammation activity.
The functional imaging of 60 RA patients assessed by the multi-modal imaging system12-15 monthsThe oxgenation levels of local joint tissues of 60 RA patients are measured by dual-wavelength PA imaging.

Countries

China

Contacts

Primary ContactMeng Yang, Doctor
yangmeng@pumch.cn8601060155494

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 11, 2026