Skip to content

Laryngoscopy for Neonatal and Infant aIrway Management (Optimise-Trial)

Laryngoscopy for Neonatal and Infant aIrway Management wIth Supplemental oxygEn (OPTIMISE): a Multi-center Prospective Randomized Controlled Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04295902
Acronym
Optimise
Enrollment
250
Registered
2020-03-05
Start date
2020-04-01
Completion date
2023-03-08
Last updated
2023-03-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Airway Management

Brief summary

The objective of this study is to compare tracheal intubation first attempt success rate with the C-MAC indirect videolaryngoscope (Karl Storz, Germany) using a Miller-Blade nr 0 or nr 1 compared to a standard direct laryngoscope with standard blades Miller nr 0 and Miller nr 1 with oxygen supplementation either in the operating room or intensive care to demonstrate that with oxygen supplementation the difference in the first-attempt success rate in favor of VL is negligible

Detailed description

Eligible children will be prepared for intubation according to the local SOPs of the pediatric anesthesia or pediatric intensive care departments. Mandatory monitoring will consist of: SpO2, HR, NIBP. Induction of anesthesia: All children included in this protocol will be pre-oxygenated before induction of anesthesia for one minute through face-mask with FiO2 = 1.0 and flow rates of 6-10L/min. The induction of anesthesia for tracheal intubation will be performed using a combination of sedative/hypnotic drugs, opioids and non-depolarizing muscle relaxant. The following medications will be mandatory as per protocol: * A non-depolarizing muscle relaxant (NDMR) drug (Rocuronium 0.5-1 mg/kg, Cis-Atracurium 0.2-0.5 mg/kg, Vecuronium 0.1 mg/kg, or succinylcholine 2 mg/kg). * One or more of the following hypnotic agents (Thiopentone 4-7 mg/kg, Ketamine 0.5-2 mg/kg, Propofol 1-4 mg/kg, Midazolam 0.5-1 mg/kg, Sevoflurane up to 8%). An opioid drug and anticholinergic can be chosen and administered at the discretion of the anesthetist in charge Before intubation: After induction of anesthesia and the administration of a muscle relaxant drug, bag-mask ventilation with FiO2 = 1.0 (flow rates of 6-10 Lmin-1) will be performed for 60 seconds until apnea sets in. After induction all patients will be paralysed with e.g. 0.5-1 mg/kg of rocuronium (2 x ED95 (standard intubation dose)) to facilitate airway management. Neuromuscular blockade will be assessed by train-of-four (TOF) monitoring. Thereafter oxygen administration, laryngoscopy and tracheal intubation are performed. During intubation: The administration of oxygen during intubation is mandatory for every study participant and is standardized as follows: * Oral intubation: For all orally intubated children, the administration of low-flow oxygen (1 l/kg/min) takes place via conventional neonatal nasal cannula. After administration of low-flow oxygen laryngoscopy and tracheal intubation are performed. * Nasal intubation: For all nasally intubated children, the administration of low-flow oxygen (1 l/kg/min) takes place direct via nasal tube. The nasal tube is introduced into one of the two nostrils up to the nasopharyngeal space and oxygen is applied to the tube via oxygen cannula. After administration of low-flow oxygen laryngoscopy and tracheal intubation are performed. For a premature neonate \< 1kg an uncuffed tube ID 2.5 will be used. For premature babies and newborn between 1kg and 3.0 kg an uncuffed tube ID 3.0 will be used. For babies \> 3.0 kg a cuffed tube ID 3.0 or an uncuffed tube 3.5 will be used. The tube will be either passed through one of the two nostrils and advanced with the help of a Magill-forceps or through the mouth. Based on the group of randomization, the child will be intubated either using the C-MAC videolaryngoscope with a Miller blade 1 (Karl Storz, Germany) or using standard direct laryngoscope, with standard blades Miller nr 0 and Miller nr 1. Miller blade nr 0 will be used for children \< 1 kg. In cases of unexpected difficult intubation, the difficult airway algorithm (14) will be followed. After the first unsuccessful intubation attempt with the randomized device, the investigators encourage to perform a second attempt with the same device but based on the clinical judgment the intubating physician can proceed to an attempt with the same technique, or change the laryngoscope blade size, switch from one technique to another and a maximum of 4 intubation attempts in total will be performed. The last intubation attempt must be performed by the most experienced physician in the room. Additional devices like stylet, bougie, etc, can be used at any stage of the intubation process. If the intubation remains unsuccessful the difficult airway algorithm will be followed and a supraglottic airway device - SAD will be inserted.

Interventions

DEVICEC-MAC indirect videolaryngoscope with blades Miller nr 0 and Miller nr 1.

Tracheal intubation performed with the C-MAC indirect videolaryngoscope (Karl Storz, Tuttlingen, Germany) with blades Miller nr 0 and Miller nr 1.

DEVICEDirect laryngoscope with blades Miller nr 0 and Miller nr 1.

Tracheal intubation performed with a standard direct laryngoscope, with standard blades Miller nr 0 and Miller nr 1

Sponsors

University of Bern
CollaboratorOTHER
Gaslini Children's Hospital
CollaboratorOTHER
Children's Hospital of Philadelphia
CollaboratorOTHER
Montreal Children's Hospital of the MUHC
CollaboratorOTHER
Insel Gruppe AG, University Hospital Bern
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
1 Days to 3 Months
Healthy volunteers
No

Inclusion criteria

* Pediatric patients requiring tracheal intubation for elective, semi-elective or urgent surgical and non-surgical indications either in the pediatric operating room, the pediatric or neonatal intensive care unit * Children aged up to 52 weeks (corrected gestational age), with legal guardians providing written informed consent before the intervention

Exclusion criteria

* Prediction of difficult intubation upon physical examination or previous history of difficult intubation, mandating a technique different than direct laryngoscopy to secure the airway * congenital heart disease mandating FiO2 \< 1.0 * cardiopulmonary collapse requiring advanced life support * intubation for emergency surgical and non-surgical indications

Design outcomes

Primary

MeasureTime frameDescription
Tracheal intubation first attempt success rate15 minutesPrimary outcome is tracheal intubation first attempt success rate with the C-MAC indirect videolaryngoscope (Karl Storz, Germany) using a Miller-Blade nr 0 or nr 1 compared to a standard direct laryngoscope with standard blades Miller nr 0 and Miller nr 1.

Secondary

MeasureTime frameDescription
Overall number of attempts15 minutesOverall number of intubation's attempts
Time required for intubation5 minutesTime required for intubation (in seconds, defined from the first introduction of laryngoscope between the lips till successful lung ventilation defined as positive capnography),
First EtCO2 after successful intubation10 minutesFirst EtCO2 after successful intubation
Occurrence and duration of moderate and severe desaturation15 minutesOccurrence and duration of moderate and severe desaturation (SpO2 \< 90% and SpO2 \< 80%), with or without bradycardia, during intubation
Use of additional devices10 minutesThe need for additional devices used at any step of intubation, the need to switch from one technique to another
Respiratory complications24 hoursRespiratory complications or complications of airway management within the first 24 hours such airway injury, mechanical resuscitation, bleeding, aspiration of gastric contents, post extubation stridor, laryngospasm, bronchospasm, need for High Flow Nasal Oxygen (if not preoperatively on oxygen), need for low flow nasal oxygen (if not preoperatively on oxygen) or need for re-intubation will be recorded
Percentage of Glottic Opening (POGO) score at any attempt of laryngoscopy5 minutesPercentage of Glottic Opening (POGO) score at any attempt of laryngoscopy

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 12, 2026