Skip to content

Validity of a Belt Mounted Accelerometer to Assess Walking Measures in Patients With Chronic Stroke

Validity of a Belt Mounted Accelerometer to Assess Walking Measures in Patients With Chronic Stroke

Status
Suspended
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04288960
Enrollment
20
Registered
2020-02-28
Start date
2022-09-01
Completion date
2022-12-30
Last updated
2022-05-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Gait, Hemiplegic, Stroke

Keywords

stroke, validity, gait

Brief summary

The aim of this study is to validate the G-walk for several gait parameters, tested against a gold standard three dimensional camera system. This research will inform researchers and practitioners as to whether the G-Walk is a suitable and valid tool to easily assess walking ability in people with chronic stroke.

Detailed description

Twenty chronic stroke survivors will be recruited for this study from an independent neuro-physiotherapy practice and community exercise programme.Gait analysis will be used to look at several gait parameters through the use of a three-dimensional visual analysis system based in our Biomechanics Lab at the University of Winchester. Participants will attend testing one testing session of approximately 1 hour. During this testing session functional measures and walking trials will be assessed. Participants will first be asked to complete a set of simple movements that will contribute towards Fugl Meyer questionnaire. Twenty eight reflective markers will then be attached to specified joints and segments of the body, such as the thigh, with double sided sticky tape to allow for data collection through the camera system to collect kinematic data. The belt mounted accelerometer (G-Walk) will be positioned around the waist over the L5 vertebrae. Participants will be asked to perform 6 walking trials of 10m to collect 3D kinematic and accelerometer gait data.

Interventions

DEVICEGwalk accelerometer walking trials

No intervention. Participants will wear a belt mounted accelerometer and complete walking trials to assess validity of the device

Sponsors

University of Winchester
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* \<3 months post stroke * Lower limb impairment * Able to stand and step independently * Functional ambulation classifications (FAC) of 2-5 * Modified Rankin Scale (MRS) of 1-3 * Cognitively aware to undertake the testing session

Exclusion criteria

* Unresolved deep vein thrombosis * unstable cardiovascular conditions * open wounds * active drug resistant infection * recent fractures of involved limb * peripheral arterial disease * incontinence * severe osteoporosis * non-weight bearing.

Design outcomes

Primary

MeasureTime frameDescription
Speed60 minutesHow quickly a participant walks overground
Cadence60 minutesSteps taken per minute
Stride Length60 minutesThe distance between strides
Swing phase duration60 minutesPercentage of the gait cycle spent in swing phase
Stance phase duration60 minutesPercentage of the gait cycle spent in stance phase
Gait cycle duration60 minutesThe time it takes to complete one gait cycle
Double support duration60 minutesPercentage of the gait cycle spend with both feet on the ground (double support)

Countries

United Kingdom

Outcome results

None listed