Skip to content

Survivorship and Effectiveness of the Ortho Development® Entrada™ Hip System for Total Hip Arthroplasty

Survivorship and Effectiveness of the Ortho Development® Entrada™ Hip System for Total Hip Arthroplasty: A Prospective Multi-Centre Cohort Study

Status
Enrolling by invitation
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04277416
Enrollment
250
Registered
2020-02-20
Start date
2020-02-28
Completion date
2032-12-31
Last updated
2022-10-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Total Hip Arthroplasty, Total Hip Replacement

Keywords

Ortho Development, Entrada Hip System

Brief summary

To evaluate Implant survival based on removal or intended removal of any component of the Entrada™ Hip System at five years of follow-up.

Detailed description

The purpose of this study is to provide clinical evidence for the safety and effectiveness of Ortho Development® Corporation's Entrada™ Hip System (Figure 1). The Entrada™ Hip System was fully introduced to the US market in July, 2018. The Entrada™ Hip System includes the Entrada™ Hip Stem, an FDA approved (510(K) # K171249) femoral stem coupled with either a cobalt chrome or Biolox® Delta Ceramic femoral head. Additionally, the stem and head are coupled with either the Escalade® or Legend® acetabular shell, both of which utilize highly cross-linked polyethylene liners.

Interventions

DEVICETotal Hip Arthroplasty

To evaluate Implant survival based on removal or intended removal of any component of the Entrada™ Hip System at five years of follow-up.

Sponsors

Oregon Health and Science University
CollaboratorOTHER
Ortho Development Corporation
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1\. Scheduled to undergo primary total hip arthroplasty using the Entrada™ Hip 2. System due to at least one of the following indications: * Osteoarthritis * Inflammatory arthropathy (Rheumatoid Arthritis, Psoriatic Arthritis, etc.) with sufficient bone stock for standard primary THA implants * Avascular Necrosis with sufficient bone stock for standard primary THA implants * Post-traumatic Arthritis * Secondary arthritis due to congenital hip dysplasia 3. Willing and able to provide written informed consent for participation in the study. 4\. Aged 18 - 80 years. 5. Able (in the Investigators opinion) and willing to comply with all study requirements and complete all study visits

Exclusion criteria

The potential participant should be excluded from enrollment if any of the following exist: 1. Body mass index ≥ 40 2. History of other orthopaedic surgery within 6 months prior to the index surgery that, in the investigator's opinion, could affect the recovery of the index THA 3. History of pyogenic arthritis in the surgical hip joint 4. Active or suspected infection in or around the surgical hip joint 5. A neurological disorder that, in the investigator's opinion, could affect lower extremity function and recovery from the index THA 6. The potential participant is incarcerated 7. Prior fusion to the index surgical hip joint 8. Any other significant disease or disorder which, in the opinion of the Investigator, may either put the participants at risk because of participation in the study, or may influence the result of the study, or the participant's ability to participate in the study. 9 . Any other contraindication to THA listed in the Entrada™ Hip Stem Labelling or Instructions for Use.

Design outcomes

Primary

MeasureTime frameDescription
Implant Survival5 - 10-year follow-upImplant survival based on removal or intended removal of any component of Entrada Hip Sys @five years follow-up. Will be measured using the Hip Disability and Osteoarthritis Outcome Score for Joint Reconstruction, the Patient-Reported Outcomes Measurement Information System Global Health Assessment, the UCLA Activity Rating Scale. Effectiveness will be assessed by achieving minimal clinically important difference (MCID) in HOOS JR and UCLA Activity scores. Hung et al. recently reported MCID of HOOS JR to be 19.68 units in an adult recon pop. The MCID for UCLA activity score has been reported to be 0.92 units.minimal detectable change for the PROMIS Global physical and mental health measures will be assessed using one-half of the standard dev between the pre and last post change score. MCID for numeric pain scale will be assessed as a 2 unit change in pain. HOOS, JR score ranges from 1-100 where 0 = total hip disability 100 = perfect hip health.

Secondary

MeasureTime frameDescription
Hip Disability and Osteoarthritis Outcome Score for Joint Reconstruction (HOOS JR)2 - 10-year follow-upThe HOOS JR patient reported outcome instrument will be assessed at one, two, five and ten years. The HOOS JR measures function and pain in the involved hip.
PROMIS Global Health Assessment (Physical health, mental health and numeric pain score)2 - 10-year follow-upThe PROMIS Global 10 patient reported outcome instrument will be assessed at one, two, five and ten years. The PROMIS Global 10 measures physical health, mental health and provides an 11 point numeric pain score.
UCLA Activity Rating Scale2 - 10-year follow-upThe UCLA patient reported outcome instrument will be assessed at one, two, five and ten years. The scale is from 1 - 10 with higher values indicating greater physical function.
Implant Survival2 - 10 year follow-upImplant survival based on removal or intended removal of any component of the Entrada™ Hip System at two and ten years of follow-up. Will be measured using the Hip Disability and Osteoarthritis Outcome Score for Joint Reconstruction (HOOS JR), the PROMIS Global Health Assessment (Physical health, mental health and Numeric pain score), and the UCLA Activity Rating Scale.
Radiographic Outcomes2 - 10-year follow-upRadiographic adverse events: Adverse events will be captured on the adverse event case report form. Radiographic adverse events will be evaluated using the zones for radiolucencies as described on the radiographic evaluation case report form. These include the femoral zones described by Gruen et al. Radiolucent lines \<2mm will be considered fibrous integration as per the review of Vanrusselt et al. Without evidence of progression these lines will not be considered evidence of aseptic loosening.
Clinical Outcomes2 - 10-year follow-upClinical adverse events: Adverse events will be captured on the adverse event case report form.
Patient Satisfaction2 - 10-year follow-upPatient Satisfaction with their hip replacement will be assessed at one, two, five and ten years. Satisfaction will be measured on a 5 point likert scale from very unsatisfied to very satisfied.

Countries

United States

Outcome results

None listed