Skip to content

Effect of Photobiomodulation by 808nm Diode Laser on the Stability of Orthodontic Mini-implants.

Effect of Photobiomodulation by 808nm Diode Laser on the Stability of Orthodontic Mini-implants: A Randomized Clinical Split-Mouth Trial.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04276402
Enrollment
22
Registered
2020-02-19
Start date
2019-07-05
Completion date
2019-11-02
Last updated
2020-02-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Malocclusion, Angle Class II

Brief summary

The study aimed to evaluate the influence of a 635nm diode laser on the stability of orthodontic mini-implants in vitro, as well as mini-implants failure rate (mini-implant loss) and patients pain level after the treatment. A randomized clinical split-mouth trial was concluded with 22 subjects (14 women, 8 men), 44 orthodontic mini-implants with a diameter 1.4mm and length of 10mm. Mini-implants were placed between teeth 3 and 4; and 13 and 14 (Universal Numbering System), in the area of the attached gingiva, 2 mm below mucogingival junction.

Interventions

PROCEDUREIrradiation of implants with 808nm laser

Irradiation of implants with 808nm laser

Sponsors

Wroclaw Medical University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* patients with class II malocclusion defect requiring lateral maxillary teeth distillation based on the use of orthodontic mini-implant; * the patients were treated first time using fixed orthodontic appliance; * no systemic diseases; * were not using anti-inflammatory drugs;

Exclusion criteria

* had used antibiotics in the previous 24 months; * smokers; * had history of radiotherapy, * taking bisphosphonate medication

Design outcomes

Primary

MeasureTime frameDescription
stability of orthodontic mini-implants60 daysThe mini-implants stability was estimated employing a Periotest device (Medzintechnik Gulden e K, Modautal, Germany). The Periotest measurement system includes the sound formed from contact between an object and a metallic tapping bar in a handpiece, which is electromagnetically driven and electronically verified. The Periotest response detection is analyzed through a fast Fourier transform (FFT) algorithm. Simply put, the Periotest answer to tapping is estimated by an accelerometer and then analyzed. The signal generated by tapping is then transformed to a value called the Periotest value (PTV), which depends on the damping characteristics of the peri-implant tissue. The Periotest Test values (PTVs) are based on a numerical scale ranging from -8 to +50, defined by mathematical computation. The lower Periotest values indicate higher implant stability and thereupon the higher absorption effect of the target objects.

Secondary

MeasureTime frameDescription
Pain level (NRS scale)24 hoursEach patient received a questionnaire for individual pain assessment (the numeric rating scale, NRS-11, grade level 0-10) immediately following placement of mini-implants. The maximum pain level was measured at both sides of the maxilla during the first day after the treatment. The NRS-11 scale consists of a conscious, subjective assessment of the pain experienced; therefore, it is used in the case of patients over ten years old. 0 = no pain, 1-3 = mild pain, 4-6 = moderate pain, 7-10 = severe pain.
mini-implants loss60 daysMini-implants survival rate was assessed during 60 days observation period.

Countries

Poland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026