Skip to content

Comparison of Two Syringe-free In-plane Techniques in Ultrasound-guided Central Venous Catheterization

Comparison of Two Syringe-free In-plane Techniques in Ultrasound-guided Central Venous Catheterization: Jugular Venous Catheterization With Oblique Approach and Brachiocephalic Catheterization Using Y-shape Image

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04256564
Enrollment
80
Registered
2020-02-05
Start date
2020-03-31
Completion date
2020-07-31
Last updated
2020-02-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Central Venous Catheter Placement

Keywords

Central venous catheter, Ultrasound, Jugular vein, Brachiocephalic vein, Endocavity micro-convex probe, Y-Shape

Brief summary

Ultrasound guidance has become a standard for central venous catheterization. The aim of this study is to compare jugular venous catheterization by using lateral oblique approach to brachiocephalic catheterization by using Y-shape imaging. The trial is planned as prospective randomized and single-blind study. Eighty patients are planned to include in this study. Patients will be assigned to two groups: Oblique visualization Group (central catheter will be placed to the jugular vein by using ultrasound-guided in-plane syringe-free technique) and Y-shape visualization Group (central catheter will be placed to the brachiocephalic vein by using ultrasound-guided in-plane syringe-free technique). Two groups will be compared in terms of number of puncture attempts, procedural time, time of preprocedural ultrasound scanning, overall success rate, complications, the ease of the catheterization process and ultrasound visibility.

Detailed description

Central venous catheters are frequently placed in the operating rooms, intensive care units and emergency departments for various indications such as intravenous fluid, drug infusion, measurement of cardiac parameters and lack of vascular access. Ultrasound guidance has become a standard for central venous catheterization. The use of ultrasound has reduced the number of puncture attempts, increased success rate and reduced complications. While the central venous catheter is inserted by ultrasound, the vessels and the needle can be imaged in real-time. In plane and out-of-plane imaging techniques can be used during catheterization. The in-plane technique ensures the entire needle visualization in ultrasound images. With the linear ultrasound probe, the vessel and needle are imaged longitudinally in the in-plane technique. When an endocavity (micro-convex) ultrasound probe is used, three central vessels (jugular, subclavian and brachiocephalic veins) are displayed as Y-shape. The advantage of the endocavity (micro-convex) probe is that it can visualize deeper tissues and deep veins, and more tissues can be imaged in wider angle. Both techniques have been successfully applied in central catheter placement. In-plane technique also ensures syringe-free cannulation where blood aspiration with a syringe attached to the needle is not necessary. The aim of this study is to compare two different ultrasound guided in-plane techniques for central venous catheterization. The investigators planned to compare jugular venous catheterization using a linear probe and lateral oblique approach to brachiocephalic catheterization using a micro-convex probe and Y-shape imaging. The primary outcomes are number of puncture attempts, success rate at first attempt, overall success rate, procedure time, ultrasound scanning time and rate of complications. Secondary outcomes are visibility of the veins and the needle in ultrasound images. The trial is a comparison of two different interventional technique and planned as prospective randomized and single-blind study. Patients aged between 18-85 years that are planned central venous catheter placement will be included in the study. Patients included in the study will be assigned into two groups by computer-assisted randomization. In the first group (Oblique visualization Group), central catheter will be placed to the jugular vein by using ultrasound-guided in-plane syringe-free technique. In the second group (Y-shape visualization Group), central catheter will be placed to the brachiocephalic vein by using ultrasound-guided in-plane syringe-free technique Linear ultrasound probe will be used in the first group, and endocavity (micro-convex) ultrasound probe will be used in the second group. In both groups, the number of puncture attempts, the number of needle redirections, and the procedure time will be recorded. The time of preprocedural ultrasound scanning will be recorded in both groups. In addition, complications during the procedure such as bleeding, hemothorax, pneumothorax, hematoma and carotid vascular injury will be recorded. Overall success rates will be assessed in each group at the end of the study. A catheterization procedure will be considered as unsuccessful after third puncture attempt or more than 10 needle redirections are needed or requires a procedure time more than 3 minutes. At this moment, the catheter will be placed to a different region or the investigators will switch to a different approach. The ease of the catheterization process will be scored between 0 and 10 by the investigator performing the process (0: the hardest, 10: the easiest). The ultrasound visibility of the needle, vessels, guide wire and catheter will be scored between 0 and 4 (4: excellent view, 3: good view, 2: Medium, 1: difficult 0: impossible to image). The recorded data will be compared between the two groups.

Interventions

PROCEDURECentral venous catheterization

A standard 20 cm (adult-size) 3-port central catheter will be placed to the indicated patients by using standard Seldinger technique (with the assist of a guide wire) under ultrasound guidance

Sponsors

Kutahya Health Sciences University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
SINGLE (Subject)

Masking description

The participant will not be aware of the catheterization technique used.

Intervention model description

There will be two parallel groups in each a different central catheterization method will be performed.

Eligibility

Sex/Gender
ALL
Age
19 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

* Patients that are planned a central venous catheter placement

Exclusion criteria

* Morbid obese patients (body mass index\> 40) * People with severe coagulopathy * Severe deformity at the neck * Skin deformity or infection at catheterization site * Congenital anomalies of central veins

Design outcomes

Primary

MeasureTime frameDescription
ComplicationsThrough study completion, an average of 4 monthsRate of complications that occur during catheterization procedure
Number of puncture attemptsDuring the whole cannulation procedure, starting from the 1st minute until the end of the procedureNumber of needle insertions to the catheterization region for placing a catheter
Cannulation procedural timeFrom the 1st minute through withdrawal of the needle, up to 3 minutesDuration of the whole cannulation procedure
Catheterization procedural timeDuring the procedure, starting from the 1st minute through placement of the catheter; up to 3 minutesDuration of the whole catheterization procedure
Number of needle redirectionsDuring the whole cannulation procedure, starting from the 1st minute through the procedure; assessed up to 3 minutesRedirections of the needle towards the vessel
Success rateThrough study completion, an average of 4 monthsOverall success rates of the procedures in each group
Success rate at first attemptThrough study completion, an average of 4 monthsSuccess rate at first attempt of the procedures in each group

Secondary

MeasureTime frameDescription
Needle visualizationThroughout the procedure; up to 3 minutesVisualization of the needle in dynamic ultrasound images
Guide-wire visualizationThroughout the procedure; up to 3 minutesVisualization of the guide-wire in dynamic ultrasound images
Catheter visualizationAt the end of catheterization procedureVisualization of the catheter in dynamic ultrasound images
Ease of the catheterization processThroughout the procedure; up to 3 minutesA subjective score assigned by the operator on a scale with a minimum value of 0 and maximum value of 10. Higher scores mean a better outcome.
Ultrasound timeThroughout the pre-procedural ultrasonography; up to 10 minutesThe duration of pre-procedural ultrasound scanning
Vessel visualizationThroughout the procedure; up to 3 minutesVisualization of the vessels in dynamic ultrasound images

Countries

Turkey (Türkiye)

Contacts

Primary ContactOnur Balaban, MD..
obalabandr@gmail.com+90 274 231 6660

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026