Skip to content

Development of a Simple, Fast and Portable Recombinase Aided Amplification Assay for 2019-nCoV

Development of a Simple, Fast and Portable Recombinase Aided Amplification (RAA) Assay for 2019-nCoV

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04245631
Enrollment
50
Registered
2020-01-29
Start date
2020-01-01
Completion date
2020-12-31
Last updated
2020-04-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

New Coronavirus

Keywords

recombinase aided amplification assay, 2019-nCoV, diagnosis, Specificity, Sensitivity

Brief summary

In late December 2019, several local health facilities reported clusters of patients with pneumonia of unknown cause that were epidemiologically linked to a seafood and wet animal wholesale market in Wuhan, Hubei Province, China. It is now confirmed that the etiology of this outbreak is a novel coronavirus, namely, 2019-nCoV. Of critical importance is rapid and simple diagnostic method to be used in clinical settings to timely inform and refine strategies that can prevent, control, and stop the spread of 2019-nCoV. Recombinase aided amplification (RAA) assay is a novel isothermal nucleic acid amplification technique in recent years, which has a variety of the advantages including high specificity and sensitivity, rapid detection (30 min), low cost, low equipment requirements and simple operation. The has successfully detected a variety of pathogens using this technique. To develop a RAA assay for 2019-nCoV with the advantages of high speed, simple operation and low cost, and overcomes the shortcomings of the existing molecular detection methods. The investigators established a real time reverse-transcription RAA (RT-RAA) assay for detection of 2019-nCoV. This assay was performed at 42°C within 30min using a portable real-time fluorescence detector, Recombinant plasmids containing conserved ORF1ab genes was used to analyze the specificity and sensitivity. Clinical specimens from patients who were suspected of being infected with 2019-nCoV were used to evaluate the performance of the assay. In parallel, The investigators also used the commercial RT-qPCR assay kit for 2019-nCoV as a reference.

Detailed description

In late December 2019, several local health facilities reported clusters of patients with pneumonia of unknown cause that were epidemiologically linked to a seafood and wet animal wholesale market in Wuhan, Hubei Province, China. It is now confirmed that the etiology of this outbreak is a novel coronavirus, namely, 2019-nCoV. Of critical importance is rapid and simple diagnostic method to be used in clinical settings to timely inform and refine strategies that can prevent, control, and stop the spread of 2019-nCoV. Recombinase aided amplification (RAA) assay is a novel isothermal nucleic acid amplification technique in recent years, which has a variety of the advantages including high specificity and sensitivity, rapid detection (30 min), low cost, low equipment requirements and simple operation. The investigators has successfully detected a variety of pathogens using this technique. To develop a RAA assay for 2019-nCoV with the advantages of high speed, simple operation and low cost, and overcomes the shortcomings of the existing molecular detection methods. The investigators established a real time reverse-transcription RAA (RT-RAA) assay for detection of 2019-nCoV. This assay was performed at 42°C within 30min using a portable real-time fluorescence detector, Recombinant plasmids containing conserved ORF1ab genes was used to analyze the specificity and sensitivity. Clinical specimens from patients who were suspected of being infected with 2019-nCoV were used to evaluate the performance of the assay. In parallel, The investigators also used the commercial RT-qPCR assay kit for 2019-nCoV as a reference. Patients who were suspected of being infected with 2019-nCoV in the hospital.

Interventions

DIAGNOSTIC_TESTRecombinase aided amplification (RAA) assay

We established a real time reverse-transcription RAA (RT-RAA) assay for detection of 2019-nCoV. This assay was performed at 42°C within 30min using a portable real-time fluorescence detector, Recombinant plasmids containing conserved ORF1ab genes was used to analyze the specificity and sensitivity. Clinical specimens from patients who were suspected of being infected with 2019-nCoV were used to evaluate the performance of the assay. In parallel, we also used the commercial RT-qPCR assay kit for 2019-nCoV as a reference. Sample types include either of nasal swab, oral swab, bronchoalveolar-lavage fluid, urea, blood, fecal.

Sponsors

Beijing Ditan Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* 1\. Suspected cases (formerly observed cases) Meet the following 2 at the same time: Epidemiological history There was a history of travel or residence in Wuhan within two weeks before the onset of illness; or patients who had had fever from Wuhan with respiratory symptoms within 14 days before the onset of illness, or had clustered onset. Clinical manifestations 1. fever; 2. It has the imaging characteristics of pneumonia mentioned above; 3. The total number of white blood cells is normal or decreased, or the lymphocyte count is decreased in the early stage of onset. * 2\. confirmed cases On the basis of meeting the criteria for suspected cases, sputum, throat swabs, lower respiratory tract secretions, and other specimens were tested by real-time fluorescent RT-PCR for positive nucleic acid detection of new coronavirus; or viral gene sequencing was highly homologous with known new coronaviruses.

Exclusion criteria

* 1\. Influenza virus, parainfluenza virus, adenovirus, respiratory syncytial virus, rhinovirus, human metapneumovirus, SARS coronavirus, and other known other viral pneumonia; * 2\. Mycoplasma pneumoniae, chlamydia pneumonia, and bacterial pneumonia; non-infectious diseases such as vasculitis, dermatomyositis, and organizing pneumonia.

Design outcomes

Primary

MeasureTime frameDescription
Detection sensitivity is greater than 95%at baselineDetection sensitivity is greater than 95%
Detection specificity is greater than 95%at baselineDetection specificity is greater than 95%

Secondary

MeasureTime frameDescription
Consistent with existing universal reagent detection rates greater than 95%at baselineConsistent with existing universal reagent detection rates greater than 95%

Countries

China

Contacts

Primary ContactYao Xie, Doctor
xieyao00120184@sina.com8610-84322200
Backup ContactXuejun Ma, phD
maxj2004@aliyun.com+86 10 58900810