Clinical and Radiographic Evaluation of Dental Implants Installed Between 2004 and 2010

Clinical and Radiographic Evaluation of Dental Implants Installed Between 2004 and 2010

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04236622
Acronym
implants
Enrollment
182
Registered
2020-01-22
Start date
2016-01-01
Completion date
2019-10-30
Last updated
2020-01-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dental Implant Failed

Keywords

dental implants, periodontal index, peri-implantitis

Brief summary

The convenience sample to be included in the present study will consist of all individuals who had implants installed at the Dentistry Clinic of the University Santo Amaro, between the years 2004 and 2010. The following criteria will be evaluated: age; sex; presence of systemic disease; area in which the implant was installed; implant diameter and height; type of prosthesis installed; presence of bone resorption and annual maintenance.

Detailed description

The control of biofilm around implants is fundamental to the success of implant therapy, and it is the duty of the dentist to inform, guide and maintain patients in order to avoid pathological processes that may lead to the loss of the implanted component. The objective of the present study will be to evaluate by clinical and radiographic parameters the condition of oral implants placed for more than five years. The convenience sample to be included in this study will be composed of all individuals who had implants installed at the Dental Clinic of the University Santo Amaro, between 2004 and 2010. The following criteria will be evaluated: age; sex; presence of systemic disease; area in which the implant was installed; implant diameter and height; type of prosthesis installed; presence of bone resorption and annual maintenance. The success and survival rate of implants through the following parameters: pain; mobility; card index (IP); bleeding rate (IS); probing depth (PS); probing bleeding (SS) that will be measured on four faces by implant: mesial, buccal, distal and lingual / palatine. For the evaluation of bone loss, a conventional periapical radiograph will be performed at the moment of patient recall. Radiographs will be scanned and analyzed using Image Tool software to verify and determine the resulting linear distance between the implant shoulder and the bone crest. Factors such as smoking, annual maintenance appointments will be related to the presence of peri-implantitis.

Interventions

OTHERPeriodontal clinical exam

The individuals will be submitted to a complete periodontal examination, with measurements obtained at four points per tooth and dental implant (mesial, distal, buccal and lingual / palatal), in all teeth / implants present, except for the third molars, the parameters evaluated will be: Probing Depth, Clinical Insertion Level, Plaque Index, Teeth Bleeding Index. The implants will be evaluated according to the parameters: presence of suppuration, probing depth, bleeding to probing and presence of biofilm around the implants. To perform the clinical examinations, the following instruments will be required: Willians millimeter probe, exploratory probe and clinical mirror. In all participants, complete periapical radiographic examinations with 14 radiographs will be performed to verify the bone cortical height level and to assist in the periodontal diagnosis.

Sponsors

Universidade Metropolitana de Santos
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
30 Years to 70 Years

Inclusion criteria

* After evaluation, individuals may be allocated into groups according to the characteristics observed, for example: carriers of single implants, patients with overdentures, individuals with systemic diseases, smokers.

Exclusion criteria

* Individuals who need to use or suspend systemic medication to perform the proposed clinical exams will be excluded from the study.

Design outcomes

Primary

MeasureTime frameDescription
Probing depth10 yearslower probing depth in patients who underwent annual maintenance

Secondary

MeasureTime frameDescription
Plaque control10 yearslower plaque index in patients who underwent annual maintenance

Countries

Brazil

Outcome results

None listed