Skip to content

Mesh Versus Suture Repair in Umbilical Hernias - A Multicenter Trial

Randomized Double-blind Controlled Multicenter Trial Comparing Suture and Mesh Repair in Small Umbilical Hernias in Adults

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04231071
Acronym
SUMMER
Enrollment
288
Registered
2020-01-18
Start date
2020-02-03
Completion date
2024-01-03
Last updated
2024-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Umbilical Hernia

Keywords

Small umbilical hernias, mesh repair, suture repair, recurrence

Brief summary

Umbilical hernia repair is one of the most common surgical performance in general surgery. Up to now, the use of suture repair has been the preferred technique for small umbilical hernia defects without any gold standard procedure. Mesh have been reserved to larger umbilical hernia defects. However, there is an increasing evidence that mesh reinforcement could be advantageous to lower the high recurrence rates also in smaller umbilical hernias. A remained important question is in what anatomical position the mesh should be placed. The investigators hypothesize that the use of an onlay mesh in small umbilical hernia defects can reduces recurrence rates without increasing postoperative complications compared to a suture repair.

Detailed description

The trial is a prospective multicenter randomized clinical trial comparing onlay mesh to suture repair. Two hundred and eighty-eight patients with a primary elective umbilical hernia below and equal to 2 cm from seven Swedish participating surgical centers will be enrolled. Randomization will be performed intraoperatively following the measurement of the defect (with stratification for centra and for the defect size) to either closing the small umbilical defect with a simple primary suture repair or closing the defect with a simple primary suture repair with an attached small flat lightweight polypropylene only mesh on the aponeurosis. Trial participants, investigators and follow-up clinical surgeons will be blinded for the assigned allocation. The primary endpoint will be recurrence at 1 and 3 years. Secondary endpoint will be surgical site postoperative complications at 30 days and pain 1 year after surgery. As follows, participants will be visiting the outpatient clinical at 30 d, 1 year and 3 year after surgery. All analyses will be performed according to the intention to treat principle and as specified in the analyses plan of the study protocol. There is no randomized clinical trial today comparing recurrence rates between an onlay mesh repair and a suture repair for small umbilical hernia defects. The trial design allows a good detection of differences in recurrence with the large sample size and the adequate follow-up. Surgeons are becoming more aware of the mesh's advantage even for the small defects, but are reluctant to use a mesh due to anatomical positions with a large dissection and an increased risk of complications. A small onlay mesh could be an easy and safe method of choice for small umbilical hernia defects to avoid increased recurrence rates. Guidelines for small umbilical hernia repairs have stressed out the need for reliable data for treatment recommendations. The investigators can expect that the trial will have a direct implication on small umbilical hernia repair standards. The clinical study protocol has underwent full external peer review as part of the funding process with Research funding from SLL (Stockholms läns landsting) Karolinska Institutet. Approval of the protocol by the Swedish Ethical Review Authority was obtained at December 2018 and January 2020.

Interventions

DEVICEOnlay Mesh group

Primary suture repair with a small only mesh on the closed defect

Sponsors

Karolinska Institutet
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

• Elective surgery of a primary umbilical hernia with a defect ≤ 2 cm that is measured clinically or with radiology.

Exclusion criteria

* Incisional hernia: previous surgery in the area of the operation * Recurrent umbilical hernia * Epigastric hernia (a defect from 3 cm below the xiphoid till 3 cm above the umbilicus) \[20\] * Another operative procedure at the same time (i.e. cholecystectomy) * An umbilical hernia with a defect \> 2 cm measured clinically, with radiology or intra-operatively * Multiple defects * Pregnancy * Infected wounds * Acute operation (incarcerated hernia) * BMI\>35 * Ascites * Immunosuppression * Anticoagulant treatment (Warfarin, NOAK) * Connective tissue disease

Design outcomes

Primary

MeasureTime frameDescription
Hernia recurrence rate3 yearTo evaluate whether an onlay mesh in the repair of primary small umbilical hernias ≤ 2 cm reduces recurrence rate compared to suture repair 3 year after surgery

Secondary

MeasureTime frameDescription
Difference in Surgical postoperative complication rate30 daysTo compare the two groups of patients with regard to surgical postoperative complications (seroma, hematoma, infection) 30 days after surgery.
Difference in Pain rate after surgery assessed by VHPQ1 yearTo compare the two groups of patients with regard to postoperative pain rate 1 year after surgery assessed by VHPQ (Ventral Hernia Pain Questionnaire)

Countries

Sweden

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 22, 2026