Skip to content

Body Impedance Method in Patients Undergoing Urgent and Elective Cesarian Section

Noninvasive Evaluation of Hemodynamics by Using Body Impedance Method in Patients Undergoing Urgent and Elective Cesarian Section

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04230525
Enrollment
95
Registered
2020-01-18
Start date
2020-03-05
Completion date
2021-06-10
Last updated
2021-03-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cesarean Section Complications

Brief summary

Independent form anesthetic methods, during C/S, considering both maternal and fetal conditions, some crucial hemodynamic changes can appear and can be claimed non invasively with the whole body bioimpedance. In this research, any kind of hemodynamic difference between this method and urgent or elective C/S case will be detected and the clinic pursuit can be developed creating an advantage in favor of both maternal and fetal conditions.

Detailed description

Independent form anesthetic methods, during C/S, considering both maternal and fetal conditions, some crucial hemodynamic changes can appear and can be claimed non invasively with the whole body bioimpedance. In this research, any kind of hemodynamic difference between this method and urgent or elective C/S case will be detected and the clinic pursuit can be developed creating an advantage in favor of both maternal and fetal conditions. Under general anesthesia, measuring the hemodynamic changes with the method of non-invasive whole-body bioimpedance system during C/S. Detection of in which phase of operations the potential changes densify and differences between urgent and elective conditions non invasively.

Interventions

DIAGNOSTIC_TESTnon invasive whole body bioimpedence system

Noninvasive hemodynamic changes will be observed by using whole-body impedance method urgent or elective cesarian section patients under general anesthesia. The whole-body bioimpedance method will be used to monitör the hemodynamic changes non invasively. This method can evaluate such as cardiac output, cardiac index, stroke volüme, stroke index, stroke volüme variations, cardiac reserve, etc. Parameters with a completely noninvasive method by using only electrots. The device consists of a laptop, a software which calculates cardiac parameters and two electrodes. The measurement is done by the following process: one of these electrodes, which looks like ECG electrodes, is stuck to the wrist and the other one to the opposite ankle or each one to two wrists.

Sponsors

Gaziosmanpasa Research and Education Hospital
Lead SponsorOTHER_GOV

Study design

Observational model
CASE_CONTROL
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 49 Years

Inclusion criteria

* Must be scheduled for elective or emergency cesarean section

Exclusion criteria

* History of cardiac surgery, and advanced cardiac valvular disease

Design outcomes

Primary

MeasureTime frameDescription
MAP1, 5, 15, and 30 minutes following the induction of the anesthesiaThe difference in mean arterial pressure during the cesarean section between elective and emergency ceasreansection subjects

Countries

Turkey (Türkiye)

Contacts

Primary ContactZuhal Cavus, MD
zuhalcavus74@gmail.com+902124041500
Backup ContactZuhal Cavus, Cavus
zuhalcavus74@gmail.com+902124041500

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026