Skip to content

Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks

Abdominal Aortic Aneurysm Sac Healing and Prevention of Endoleaks - A Prospective Single Center Safety Study

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04227054
Acronym
AAA-SHAPE
Enrollment
15
Registered
2020-01-13
Start date
2020-09-09
Completion date
2028-08-30
Last updated
2025-12-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Abdominal Aortic Aneurysm

Brief summary

To determine the safety and efficacy of IMPEDE-FX Embolization Plug and/or IMPEDE-FX Rapid Fill to fill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft.

Interventions

Fill an abdominal aortic aneurysm (AAA) sac outside of an endovascular aneurysm repair (EVAR) stent graft

Sponsors

Shape Memory Medical, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* ≥18 years of age * A candidate for elective EVAR of an infrarenal aortic aneurysm ≥5.5 cm in diameter in men and ≥5.0 cm in women

Exclusion criteria

* An inability to provide informed consent * Enrolled in another clinical study * Concomitant iliac artery ectasia or aneurysm (common iliac artery diameter \>24 mm) * Patent AAA sac feeding vessels (within the sac) \>4 mm in diameter * Volume of AAA sac to be filled after stent graft placement \<30 mL or \>135 mL, based on pre-procedure CTA (i.e. aortic flow volume exclusive of stent graft volume) * Use of aortic stent grafts other than the Gore Excluder AAA Endoprosthesis, Cook Zenith Flex AAA Endovascular Graft, Medtronic Endurant II Stent Graft, or Endologix Ovation Alto Abdominal Stent Graft System to treat the AAA * Planned use of the chosen stent graft outside its instructions for use (IFU) * Planned use of fenestrated or chimney stent grafts * Study participants in which stent graft placement is abandoned for any reason, and/or in which the investigator decides, during the course of the stent graft placement, that the study procedure may not be appropriate * Planned use of embolic devices other than the investigational product to embolize the AAA sac * Vascular disease and/or anatomy that preclude the safe access and positioning of a catheter to deliver the investigational product into the AAA sac * Ruptured, leaking, or mycotic (infected) aneurysm * Aneurysmal disease of the descending thoracic aorta * Coagulopathy or uncontrolled bleeding disorder * Long-term (\>6 months prior to the procedure) use of direct oral anticoagulant or any vitamin K antagonist anticoagulant use * Serum creatinine level \>2.5 mg/dL; * Cerebrovascular accident within 3 months prior to the procedure * Myocardial infarction and/or major heart surgery within 3 months prior to the procedure * Atrial fibrillation that is not well rate controlled * Unable or unwilling to comply with study follow-up requirements * Life expectancy of \<2 years post-procedure * Known hypersensitivity or contraindication to platinum, iridium, or polyurethane * A condition that inhibits radiographic visualization during the implantation procedure * History of allergy to contrast medium that cannot be managed medically * Uncontrolled co-morbid medical condition, including mental health issues, that would adversely affect participation in the study * Pregnant or a lactating female. For females of child-bearing potential, based on a positive pregnancy test within 7 days prior to the procedure or refusal to use a medically accepted method of birth control for the duration of the study * Prisoner or member of other vulnerable population.

Design outcomes

Primary

MeasureTime frameDescription
Incidence of related major adverse events (MAEs)30 days post-procedureIncidence of related major adverse events (MAEs)
Efficacy - Technical SuccessImmediately after the interventionTechnical success, defined as filling of the residual flow lumen of the AAA sac with investigational products

Secondary

MeasureTime frameDescription
Incidence of related serious adverse events (SAEs)5 years post-procedureIncidence of related serious adverse events (SAEs)
Efficacy - Type II endoleaks5 years post-procedureIncidence of type II endoleaks
Efficacy - Type I and type III endoleaks5 years post-procedureIncidence of type I and type III endoleaks
Efficacy - Open repair5 years post-procedureRate of conversion to open AAA repair
Efficacy - Reinterventions5 years post-procedureRate of other reinterventions related to the AAA sac growth and/or complications
Efficacy - AAA sac diameter/volume5 years post-procedureChange in AAA sac diameter/volume
Incidence of related major adverse events (MAEs)5 years post-procedureIncidence of related major adverse events (MAEs)

Countries

New Zealand

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026