Skip to content

microRNA Testing for Identification of Personalized Weight Management

Efficacy of microRNA Testing for Identification of Personalized Weight Management Strategy in Obese and Overweight Individuals.

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04217850
Enrollment
26
Registered
2020-01-03
Start date
2020-01-13
Completion date
2020-06-30
Last updated
2022-05-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Overweight and Obesity, Weight Loss

Brief summary

Certain blood markers are related to one's ability to successfully lose weight by diet and exercise. Currently, the laboratory tests used to measure these blood markers are expensive and time-consuming. Recently, the Electrical and Computer Engineering Department, at NDSU, invented a device that may be able to measure these blood markers much more quickly and affordably. This study is designed participate, to compare our new device to previous methods. If the new sensor is successful, it will be used as diagnostic tool to personalize weight loss strategies.

Detailed description

Obesity is increasing exponentially in the United States (US), and over 160 million Americans are either overweight or obese. A combined diet and exercise program is the most cost-effective alternative for weight management, but there is a considerable inter-individual variability in losing weight via this method, which leaves many individuals frustrated and unable to adhere to programs throughout the lifespan. Therefore, the inability to identify the individuals who will likely succeed with diet and exercise for weight management is a critical roadblock to treating obesity. Recent studies have shown that significant variability in weight loss response to diet and exercise could be attributed in part to individual epigenetic makeup. One potential approach for monitoring the epigenetic response during weight-loss interventions is small non-coding circulating RNAs, called microRNAs (miRNAs or miRs), in the circulating blood. Studies have shown that miR-140 and 935 could be used as blood biomarkers to identify individuals who will succeed in managing their weight through diet and exercise. Moreover, during a short diet and exercise intervention, fluctuations of expression levels of biomarker miRNAs pre- and post-intervention have produced unique signature changes only in the individuals who continued the intervention for an extended period of time and attained a healthy body weight. Thus, if implemented early in a medical weight loss program it could allow for the patient to have a focused individualized treatment. A major barrier that prevents the use of miRNAs in weight loss interventions is the inability of accurately quantifying miR-140 and 935 levels in blood samples. To minimize the miRNA contamination from red-blood cell lysis, miRNA analysis must be performed within 30 minutes of blood draw. Current miRNA detection and quantification technologies take hours/days to quantify miRNAs, require bulky equipment, and are expensive. In addition, current miRNA detection methods do not have sufficient sensitivity, detection span and specificity for clinical sample analysis. To address this need, PI. Nawarathna has recently developed a highly sensitive disposable miRNA sensor that can quantify miRNAs in point-of-care settings within 15 minutes with an assay cost of $50 per test. However, the effectiveness of the developed miRNA sensor to accurately quantify the variations of target miRNA levels (miR-140 and 935) pre- and post-diet and exercise intervention is unknown. The objective of the proposed work is to investigate the efficacy of this miRNA sensor as a potential diagnostic device in weight management. If successful, the impact of proposed the research is two-fold: first, development of a point-of-care diagnostic device (miRNA sensor) for providing a personalized strategy for weight management (diet and exercise or bariatric surgery) and second, ability to immediately expand miRNA detection to measure other factors that can impact overall well-being (e.g.: mental and emotional health, stress, and fatigue) and diseases (e.g.: cancer, cardiovascular diseases, and others). The objective of the proposed research will be achieved through following this specific aim: Aim: To investigate if the miRNA sensor is capable of identifying individuals who will consistently lose weight with energy restricted diet and exercise intervention. The proposed research will develop a pilot study with overweight individuals as participants. Subjects will participate in the diet and exercise intervention for 12 weeks and miRNA analysis will be performed at 3 time points during the intervention (pre-mid-post). We will then investigate the effectiveness of the sensor. The miRNA sensor technology, once fully developed, will be similar to a finger prick glucose monitor. Once commercially available, miRNA sensors can be purchased and used for diagnostic applications in clinics or self-testing at home or remote and rural area clinics and hospitals. Therefore, the outcomes will fundamentally advance how the individualized weight management method is selected. For this reason, this research has a positive translational impact on human health.

Interventions

OTHER250 kcal Dietary Energy Restriction

The nutrition intervention will be individualized and implemented as a free-living energy-restricted eating plan where energy intake will be based on a mild restriction (approx. 250 kcal/day).

OTHERAerobic Exercise

Supervised aerobic exercise will be combined with the energy restriction. Individuals will perform aerobic exercise (treadmill, cycle, or rower or combination) 4-5 days per week for 12 weeks. At each session they will expend 250 or more calories to further meet or exceed the 500 kcal energy deficit.

Sponsors

North Dakota State University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* generally healthy * body mass index 25-34.9 * able to do physical activity and exercise

Exclusion criteria

* currently participating in a structured diet or excise program, * pregnant, * currently use any nicotine product * diagnosed neuromuscular disease * diabetes, * uncontrolled high blood pressure, * diagnosed cancer, * previously had a heart attack or other chronic heart related conditions that are not controlled with medicine * difficulty moving without assistive devices or walking one-quarter mile * are taking medications that influence muscle size (testosterone, growth hormone, etc.), * have had bariatric surgery * have a body mass greater than 350lbs, * fear blood, blood draws, or needles * adverse reaction to a blood draw in the past.

Design outcomes

Primary

MeasureTime frameDescription
Body massChange across weeks 0, 6, 13Change in body mass (kg) derived from scale
micro RNA 140Change across weeks 0, 6, 13Venous blood concentrations (M) of micro RNA 140 will be measured using our sensor.
micro RNA 935Change across weeks 0, 6, 13Venous blood concentrations (M) of micro RNA 935 will be measured using our sensor.
Body CompositionChange across weeks 0, 6, 13Change in body composition (% fat) derived from dual x-ray absorptiometry
Lean body massChange across weeks 0, 6, 13Change in lean body mass (kg) derived from dual x-ray absorptiometry
Fat massChange across weeks 0, 6, 13Change in fat mass (kg) derived from dual x-ray absorptiometry

Secondary

MeasureTime frameDescription
Total cholesterolChange across weeks 0, 6, 13Change in total cholesterol (mg/dL) from Piccolo Xpress Blood Chemistry Analyzer
TriglyceridesChange across weeks 0, 6, 13Change in triglycerides (mg/dL) from Piccolo Xpress Blood Chemistry Analyzer
Low-density lipoprotein (calculated)Change across weeks 0, 6, 13Change in low-density lipoprotein (mg/dL) from Piccolo Xpress Blood Chemistry Analyzer
Very low-density lipoprotein (calculated)Change across weeks 0, 6, 13Change in very low-density lipoprotein (mg/dL) from Piccolo Xpress Blood Chemistry Analyzer
High-density lipoproteinChange across weeks 0, 6, 13Change in high density lipoprotein (mg/dL) from Piccolo Xpress Blood Chemistry Analyzer

Countries

United States

Outcome results

None listed