Skip to content

Comparative Evaluation of Various Patient Centered Outcomes Following Gingival Depigmentation Using Diode LASER in Different Modes: A Randomized Clinical Trial

A Comparative Evaluation of Various Patient Centered Outcomes Following Gingival Depigmentation Using Diode LASER in Different Modes: A Randomized Clinical Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04217434
Acronym
LASER
Enrollment
40
Registered
2020-01-03
Start date
2018-11-20
Completion date
2020-11-22
Last updated
2020-01-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Analgesia, Healing Surgical Wounds, Pain, Postoperative, Temperature Change, Body

Brief summary

Purpose of this study is to clinically evaluate and compare various patient centered outcomes using diode LASER in Continuous mode (CW) and Pulsed Mode (PM) using 300µm and 400µm fiber for depigmentation procedure.

Detailed description

The colour of gingiva has a tremendous impact on the esthetics of the smile. Clinically gingival melanin hyperpigmentation is presented as 'black gum' which is common esthetic problem especially for those who have gummy smile. Currently the growing aesthetic concerns among the patients require the removal of hyper pigmented gingival areas to create an aesthetically-pleasant smile. The harmony of the smile is determined not only by the shape, position and colour of the teeth or lips as well as by the by the gingival tissues.Several attempts have been made for removal of gingival pigmentation by different techniques like scalpel, electrocautery, LASER etc. Each technique has its own advantages and disadvantages. In the present study an effort has been made to compare two different modes viz. Continuous mode and Pulsed mode of LASER in the treatment of depigmentation.Diode LASERs for dentistry operate in the near infrared region. The most commonly used wavelengths are 810, 940 and 980 nm , because these wavelengths are very well absorbed by pigmented tissues, haemoglobin and melanin.There are several different ways LASER light operates: Continuous wave (CW), Pulse wave mode (PM). The continuous wave diodes emit continuous LASER energy with a fixed power output for the entire duration. Pulse modulated diodes create a 'pulse' by cutting the beam or turning LASER on & off \[1s\] at regular intervals. During the first years of diode LASER treatment in dentistry only CW mode was possible but application of 3-4 Watt in CW mode led to carbonization of the soft tissue.To approach better results in soft tissue treatment without much carbonization it was necessary to interrupt the CW mode. That was done by chopping the CW mode. Pulses down to several 100μs were released.LASER in Continuous wave mode is suggested in some studies to cause increase in surgical site temperature which may cause necrosis or jeopardize healing. Application of the LASER in Pulsed mode prevents overheating of surrounding tissues. This study aims to determine the comparative increase in the onsite temperature between the two modes.Decrease in post-operative pain is likely to reduce the consumption of Non-steroidal Anti-inflammatory Drugs (NSAID's). The study aims to quantify the need for NSAID's post-operatively in both Pulsed and continuous wave modes and also in 300µ and 400µ fibers. The change in the diameter of the fibers used in LASER irradiation could bring about a change in the outcome of the procedure as small diameter fibers means high energy density, faster cutting and more heat whereas with larger diameter fibers more energy is needed to cover a broader area to work more quickly and less heat.

Interventions

PROCEDURE400 µm fibre length will be used in continuous contact mode

Diode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 400 µm fibre length will be used in continuous contact mode at a power setting of 1.5 - 3W. Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.

PROCEDURE400 µm fibre length will be used in pulsed contact mode

Diode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 400µm fibre length will be used pulsed contact mode at a power setting of 1.5 - 3W. Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.

PROCEDURE300 µm fibre length will be used in continuous mode

Diode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 300 µm fibre length will be used continous contact mode at a power setting of 1.5 - 3W. Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.

PROCEDURE300 µm fibre length will be used in pulsed contact mode

Diode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®\[ 2% lignocaine in 1:80000 adrenaline\]. LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes using 300 µm fibre length will be used pulsed contact mode at a power setting of 1.5 - 3W. .Simultaneously, increase in temperature on site will be recorded using FLUKE 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain.Post operative instructions will be given.

Sponsors

Krishnadevaraya College of Dental Sciences & Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

1. Presence of melanin hyper pigmentation of the anterior labial gingival segment 2. Systemically healthy patients who desires correction of gingival pigmentation 3. Patients with healthy periodontium 4. Patients in age group of 18-45 years old

Exclusion criteria

1. Presence of uncontrolled systemic diseases example uncontrolled Diabetes, Hypertension etc. 2. Pregnant and lactating women 3. Gingival enlargement 4. Patients who are on Non-steroidal Anti-inflammatory Drugs (NSAID's) or who have taken antibiotics for last 6 months 5. Patients who are on drugs that could possibly affect gingival status like phenytoin 6. Patients who have undergone any form of oral surgery in last 6 months 7. Asthma patients

Design outcomes

Primary

MeasureTime frameDescription
rise in temperaturebaselineFLUKETM 59 Mini (IR) infrared thermometer is used to measure temperature at surgical site, more rise in temperature indicate more carbanoization.
Healing of gingiva1st day post operativelyhick healing index- score ranges from 0 to 4, higher values indicate the worst outcomes.
epithelial healing7th day post operatively3% of hydrogen peroxide is applied on the operated area. no bubble- complete epithelization, bubble formation- incomplete epithelization.
need of analgesics1st day post operativelyon scale of 0-9, where higher variable represents more pain
pain assessing1st day post operatively.visual analogue scale (VAS) method - a questionnaire will be given to the patients in which their responses for Visual Analog Score that ranges from 1-10 values and highest values indicate the worst outcomes.

Secondary

MeasureTime frameDescription
duration of operationintraoperativetime duration taken for completing surgical procedure in minutes
presence/ absence of carbonizationBaselineon scale of 0-3, higher value indicates more carbonization
ease of cuttingBaselineon scale on 1-3, more value represents better cutting.

Countries

India

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026