Airway Aspiration, Airway Complication of Anesthesia, Complication of Anesthesia, Endoscopic Ergonomics, ERCP Airway Management, Esophagus Injury, Supraglottic Airway Efficiency
Conditions
Keywords
LMA gastro airway, Gastro-laryngeal tube, ERCP, airway complications
Brief summary
Comparison of second generation supraglottic airway devices about anesthesiologist, endoscopist and patient, which used for gastrointestinal procedures. The investigators believe that the endoscope will be easier to reach by the part of GLT extending to the esophagus, but the structural stiffness of this part may damage the esophageal mucosa. On the other hand, since the endoscopic canal of the LMA® Gastro ends at the upper end of the esophagus, it may be more difficult to orient the endoscope to the esophagus, but it may be superior in terms of ventilation efficiency. Therefore these two device worth for comparing.
Detailed description
Supraglottic airway (SGA) devices are produced for avoiding endotracheal intubation for anesthesic interventions. Second generation SGA's like GLT and LMA® Gastro airway are using for endoscopic biliopancreatic procedures. Both of them have an airway canal and endoscopic canal. Although they can use for same reason, their designs are different. So, their airway securities, endoscopic manipulations and complications, would be different. This study planned as single blind. American Society of Anesthesiologists (ASA) Physical status 1-2 100 patients which will be take endoscopic retrograde cholangiopancreatography (ERCP) included. The study starts after randomization and ends after discharge from the recovery room. All patients will be monitorised for hemodynamic parameters. Depth of anesthesia will be provided by bispectral index (BIS) monitoring. After anesthesia induction SGA will placed by an experienced anesthesiologist. Bilateral chest movements and auscultation, capnogram graphy and oropharyngeal leak pressure test will be used for confirmation of placement. After procedure endoscopist will take pictures of esophagus and hypopharynx. After extubation and sufficient consciousness and breathing of patient, patients will be transferred to post-anaesthesia care unit (PACU). Vital parameters will continue to monitoring in PACU. Patients will be discharge as usual with an Aldrete score ≥ 9. Data will be collected during the procedure and in recovery room. Data will be stored in electronic database without mention to patient's name.
Interventions
comparing efficiency and complications of second generation airway devices which can use for gastrointestinally procedures
Sponsors
Study design
Masking description
closed envelope.technique
Eligibility
Inclusion criteria
* ASA Physical Status 1-2 * Elective Procedures * Weight 50-100 Kg
Exclusion criteria
* Laryngeal mask airway contraindications. * Anesthesic drug allergies * Height \<155 cm * Body Mass index \> 35 kg/m2 * Alcohol or narcotic drug usage * Restrictive or obstructive pulmonary diseases * Hepatic cardiac or renal failure * Psychotic problems * Neurologic or cognitive deficiencies. * Pregnancy * Difficult airway or facial deformities * Previous cervical surgery or cervical radiotherapy * Previous esophagus surgery * High risk of pulmonary aspiration
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Oropharyngeal leak pressure | Intra-operative; after device insertion | Oropharyngeal leak pressure is the airway pressure at which the circuit pressure stabilizes by closing the expiratory valve of the circle system at a constant gas flow of 3 L / min. |
| Endoscopist satisfaction analysis: score | Immediately after the procedure | Endoscopist will score from 0 (worst) to 10 (best) |
| Leakage rate percentages | Intra-operative; after device insertion at first minute | The leakage rate percentage is the calculation of the difference between the adjusted tidal volume and the exhaled tidal volume and then proportioning to the adjusted tidal volume. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Hypopharyngeal/Esophageal Mucosal status | Within the first minute after the procedure is completed, while the duodenoscope is being removed while it passes through the esophagus and hypopharynx | Number of patients with hyperemia, laceration (while extubating patient, endoscopist will take pictures of esophagus for if there is any mucosal damage). Esophageal and hypopharyngeal mucosal damage was determined in 5 grades by a visual mucosal damage scoring system \[grade 1- normal mucosa, grade 2- mild hyperemia, grade 3-severe hyperemia, grade 4-bloody gross hyperemia, grade 5- laceration\]. |
| Blood staining on the device | Immediately after removing the supraglottic airway device | Whether there is blood on the supraglottic airway device or not |
| Presence of sore throat | One hour after extubation | Sore throat if present, was classified as mild, moderate or severe. |
Countries
Turkey (Türkiye)