Evaluation Of Performance & Complications of Pacemakers in Children

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04163770
Enrollment
40
Registered
2019-11-15
Start date
2020-01-15
Completion date
2021-02-15
Last updated
2019-11-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Disorder of Cardiac Pacemaker System

Brief summary

Pacemakers were introduced into clinical practice several decades ago and currently are used in a growing number of patients. Since insertion of the first cardiac Pacemaker in 1958, vast changes have occurred in both the technology of the devices and their indications. Devices have evolved from single-lead and fixed-rate systems to multi chamber rate-responsive systems with increasingly sophisticated software . Pediatric Pacemaker implants comprise less than 1 % of all implants. The indications for pacing in newborns and infants are divided predominantly into three groups: congenital abnormalities of the conduction system, acquired heart blocks after cardiac surgery for correction of congenital defects, and sinus node diseases

Detailed description

Although advances in device and lead technology have expanded the ability to implant pacemakers and defibrillators in children and patients with congenital heart disease , a number of challenges exist that can complicate long-term pacing success in this unique population . These include a long duration of pacing need, a more active lifestyle in young patients, somatic growth, congenital cardiac abnormalities, and relatively small patient and vessel size. Traditional stylet driven leads have limited maneuverability, making lead placement in smaller patients and those with structural abnormalities more challenging. Additionally, the larger lead diameter needed to accommodate the stylet has been correlated with increased risk of venous complications in children . Furthermore, many congenital heart disease patients have structural abnormalities and cardiac scarring that require pacing leads to be placed in non-standard locations, and selective site pacing can be difficult to achieve with stylet-driven leads . Pacing therapy in children must take into account several unique pediatric issues: (1) small physique; (2) somatic growth; (3) presence of intracardiac shunts; and (4) a complex anatomical heart structure. It is important to understand these features when deciding whether pacing is indicated, as well as when selecting the time to implant and how to implant. The 2008 Guidelines of the American College of Cardiology /American Heart Association /Heart Rhythm Society summarize indications for pacing treatment in children. Atrioventricular block including congenital atrioventricular block associated with cardiac surgery or a natural history of complex congenital heart disease such as corrected transposition of the great arteries are the most important indications for pacemaker implantation in children 8-13. In pediatric patients, atrioventricular block that does not recover within 7-10 days after cardiac surgery is associated with a risk of sudden cardiac death in the future, so pacemaker implantation is recommended. Dual-chamber pacemakers are often selected for adult patients with atrioventricular block. Dual-chamber pacemakers pacing requires two endocardial leads. In infants, this presents a problem because the venous diameter is small and may cause venous obstruction. A single chamber ventricular pacemaker instead of a dual-chamber pacemaker is a good alternative choice in children with complete atrioventricular block and normal sinus node function, because it requires only a single lead and may reduce the possibility of venous occlusion. The high heart rate of infants is another issue. The mean heart rate of an infant is 100 bpm or faster, increasing to 180-200 bpm or above when crying. In an infant with atrioventricular block, the atrial rate becomes so rapid that it may exceed the maximum programmable upper tracking rate, which is limited by the post-ventricular atrial refractory period and atrioventricular delay. Under the condition where the atrial heart rate exceeds the maximum programmable upper tracking rate, symptomatic 2:1 atrioventricular block may occur. Therefore, in infants with a small body size and a rapid ventricular rate, single chamber ventricular pacing or single-chamber ventricular pacing with rate response should be selected.

Interventions

DEVICEcaliberation of pacemaker

evaluation of ventricular impedence, ventricular sensing, ventricular capture threshold

Sponsors

Assiut University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
No minimum to 18 Years
Healthy volunteers
Yes

Inclusion criteria

• Pediatric age group 0 month -18 years Indicated for permanent cardiac pacing

Exclusion criteria

* Cardiomyopathy unrelated to rhythm disturbance. * Significant systemic disease apart from the cardiac one

Design outcomes

Primary

MeasureTime frameDescription
Performance of pacemakers in children1 yearthe performance will be assessed by Ventricular impedence in ohms