Skip to content

EBUS-Miniforceps Biopsy Specimen Acquisition for PD-L1 Testing in Nonsmall Cell Lung Cancer

EBUS-Miniforceps Biopsy Specimen Acquisition for PD-L1 Testing in Nonsmall Cell Lung Cancer: A Feasibility Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04159025
Enrollment
20
Registered
2019-11-12
Start date
2020-01-08
Completion date
2022-02-25
Last updated
2023-03-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Non Small Cell Lung Cancer, NSCLC

Brief summary

The incorporation of PD-L1 testing into clinical practice has progressed at a rapid pace, and now offers an additional line of therapy for eligible patients with nonsmall cell lung cancer. The assay used to detect circulating levels of PD-L1 currently requires core biopsies, and is not approved to be used for specimens collected through a needle based cytological technique. Though endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) has markedly improved the manner in which patients are diagnosed and staged for lung cancer, alternative means of tissue collection may be mandatory to offer patients access to newer lines of therapy such as PD-L1 inhibition. EBUS-miniforceps biopsy may allow bronchoscopists to obtain core biopsy specimens through the technique of endobronchial ultrasound, so that more invasive approaches such as surgery may be avoided. Feasibility using this approach would indicate that all patients being staged with endobronchial ultrasound procedures would be candidates for PD-L1 testing and potential therapy. This study is proposed to evaluate the feasibility of using endobronchial ultrasound guided miniforceps biopsy (EBUS-MFB) to acquire tissue that is adequate for PD-L1 testing. Feasibility in this study is defined as the ability to obtain adequate material during EBUS procedures to perform PD-L1 testing.

Interventions

DEVICECoreDx Pulmonary Mini-Forceps

Manufactured by Boston Scientific

Sponsors

Boston Scientific Corporation
CollaboratorINDUSTRY
Washington University School of Medicine
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with central lung lesion 1cm in size or larger identified on chest CT with the intention to undergo bronchoscopic evaluation and biopsy. The decision to pursue biopsy will be made by the treating physician and agreed upon by the patient. * Are at least 18 years old * Are able to provide informed consent * Are not pregnant as confirmed by bHCG testing prior to procedure

Exclusion criteria

* Patients who refuse to participate * Are less than 18 years of age * Are pregnant * Are physically unable to tolerate flexible bronchoscopy or moderate sedation as determined by the bronchoscopist * Are unable to provide informed consent * Are on anticoagulant medications and who cannot safely discontinue their medication prior to their procedure at the recommendation of their treating physician

Design outcomes

Primary

MeasureTime frameDescription
Feasibility of Utilizing Endobronchial Ultrasound Guided Miniforceps as Assessed by the Number of Participants From Whom Adequate Amounts of Tissue to Perform PD-L1 Testing Was AcquiredCompletion of biopsy (day 1)* Adequacy will be defined as sufficient core biopsy material to perform the PD-L1 assay specific for nivolumab * Any specimen in which the requested assay returns as insufficient material to perform testing will be deemed an inadequate specimen. * Feasibility cannot be determined until the completion of biopsy for all patients enrolled

Secondary

MeasureTime frame
Rate of Adverse EventsThrough 24 hours after biopsy procedure

Countries

United States

Participant flow

Participants by arm

ArmCount
Endobronchial Ultrasound Guided Miniforceps Biopsy
* Standard of care convex-probe endobronchial ultrasound and transbronchial needle aspiration followed by rapid on-site evaluation. If evaluation yields a diagnosis of nonsmall cell lung cancer then EBUS-MFB will be performed. * With the EBUS bronchoscope, 6 needle punctures will be made into the targeted lymph node with the 22 gauge aspiration needle. The needle will be removed and the 1mm miniforceps will be passed through the working channel of the EBUS-bronchoscope into the targeted lymph node through the puncture site made using the 22 gauge needle using continuous endobronchial ultrasound guidance. The miniforceps will be used to obtain a core biopsy of the targeted lymph node - 8 core biopsies will be obtained from each targeted lymph node using this technique
20
Total20

Baseline characteristics

CharacteristicEndobronchial Ultrasound Guided Miniforceps Biopsy
Age, Continuous67 years
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
20 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
4 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
16 Participants
Region of Enrollment
United States
20 participants
Sex: Female, Male
Female
7 Participants
Sex: Female, Male
Male
13 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 20
other
Total, other adverse events
0 / 20
serious
Total, serious adverse events
0 / 20

Outcome results

Primary

Feasibility of Utilizing Endobronchial Ultrasound Guided Miniforceps as Assessed by the Number of Participants From Whom Adequate Amounts of Tissue to Perform PD-L1 Testing Was Acquired

* Adequacy will be defined as sufficient core biopsy material to perform the PD-L1 assay specific for nivolumab * Any specimen in which the requested assay returns as insufficient material to perform testing will be deemed an inadequate specimen. * Feasibility cannot be determined until the completion of biopsy for all patients enrolled

Time frame: Completion of biopsy (day 1)

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Endobronchial Ultrasound Guided Miniforceps BiopsyFeasibility of Utilizing Endobronchial Ultrasound Guided Miniforceps as Assessed by the Number of Participants From Whom Adequate Amounts of Tissue to Perform PD-L1 Testing Was Acquired13 Participants
Secondary

Rate of Adverse Events

Time frame: Through 24 hours after biopsy procedure

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Endobronchial Ultrasound Guided Miniforceps BiopsyRate of Adverse Events0 Participants

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026