Skip to content

REC2Stim as a Treatment for Refractory Epilepsy in the Primary Sensorimotor Cortex.

Rational Extra-eloquent Closed-loop Cortical Stimulation (REC2Stim) as a Treatment for Refractory Epilepsy in the Primary Sensorimotor Cortex.

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04158531
Acronym
REC2Stim
Enrollment
10
Registered
2019-11-08
Start date
2019-11-04
Completion date
2022-07-31
Last updated
2019-12-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Epilepsy Intractable, Epileptic Seizure, Motor Seizure

Keywords

cortical electrical stimulation, seizure detection, network stimulation

Brief summary

People with central lobe epilepsy (CLE), with seizures arising from the primary sensorimotor cortex, typically show a high rate of convulsive seizures that do not respond to anti-epileptic drugs, but have a large impact on quality of life. They often seek surgical relief, but since the area contains the body's indispensable sensorimotor representation, CLE surgery will lead to permanent functional deficits. Cortical stimulation case studies in CLE have shown seizure frequency reduction of more than 90%, but in our experience, stimuli in the central lobe can hardly be applied without interfering with motor function. The investigators propose cortical electrical stimulation therapy of a conceptually novel type. The investigators systematically determine individual stimulation settings, stimulation site and a seizure detection algorithm. In REC2Stim (Rational Extra-eloquent Closed-loop Cortical Stimulation), at the start of a seizure, a train of electric pulses is delivered to a nearby extra-eloquent area connected with the epileptogenic area within the sensorimotor cortex. Success will constitute a therapeutic modality for pharmaco-resistant patients with an epileptic focus in eloquent areas.

Detailed description

The investigators will include ten patients with CLE, aged 16 years and older, in whom pre-surgical chronic intracranial EEG monitoring has revealed a seizure onset in the primary sensorimotor cortex. Patients should have on average at least two seizures per day. Clinical intracranial EEG monitoring (normally 7-10 days) will be extended with two extra monitoring days, for systematic testing of different stimulation settings and their effect on interictal epileptiform EEG activity (as a surrogate marker for ictal epileptiform activity), from which site and parameters for chronic stimulation will be determined. Upon removal of the clinically implanted electrodes, a neurostimulator with sensing capabilities, Activa PC+S, will be implanted and attached to two subdural leads with electrodes covering the predefined stimulation site and the eloquent epileptogenic area. During a data collection phase, stimulation-free data will then be collected to train the seizure detection algorithm up to at least 50% sensitivity. Finally, the REC2Stim phase will be started, in which cortical stimulation is applied when seizure activity is detected. Study participation is one year. When REC2Stim turns out effective in month 10 and 11 after implantation of the neurostimulator, 2 weeks of sham stimulation will follow in month 12.

Interventions

DEVICEECoG sensing and stimulation

Implant electrodes and a sensing+stimulation device, and use this for suppression of seizure activity

Sponsors

UMC Utrecht
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

This study is an early feasibility study in which the effect and safety of cortical network stimulation in patients with central lobe epilepsy is investigated.

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* potential central lobe epilepsy * on average 2 or more seizures per day or ongoing Epilepsia Partialis Continua (EPC) * mentally and physically capable of giving informed consent * minimally 3 anti-epileptic drugs been admitted without effect on seizure frequency (refractory epilepsy)

Exclusion criteria

* coagulopathy, including use of anticoagulant or antiplatelet agents * known allergy to the materials of the implant * progressive neurological or systemic disease * contra-indications to the presence of a chronically implanted device, such as the need for repeated MRI, or concurrent infections * any brain lesion that would place the patient at an elevated risk for bleeding * any progressive brain disease, e.g. Rasmussen's encephalitis or glioma * presence of any active implanted metallic device, such as cardiac pace-maker, vagal nerve or deep brain stimulator, cochlear implants, spinal cord stimulator or metallic parts from non-medical origin * presence of aneurysm clips * seizure onset zone (SOZ) outside eloquent cortex

Design outcomes

Primary

MeasureTime frameDescription
seizure frequency - diary recorded in an app (MedApp)study start until 1 year after implantation of last patientthe number of seizures per day
seizure severity - diary recorded in an app (MedApp)study start until 1 year after implantation of last patientthe severity of the seizures, experienced by the patient. A scale of intensity from 0-10 (low - high severity) can be selected. Also the seizure type can be selected.

Secondary

MeasureTime frameDescription
Motoric functioning - sensibility as part of neurological examinationstudy start until 1 year after implantation of last patientThe investigators perform neurological examination during each outpatient clinic visit. Sensibility is rated as normal or abnormal.
Motoric functioning - reflexes as part of neurological examinationstudy start until 1 year after implantation of last patientThe investigators perform neurological examination during each outpatient clinic visit. Reflexes are rated as normal or abnormal.
Simple functional abilities - nine hole peg teststudy start until 1 year after implantation of last patientThe investigators use the nine-hole peg test before implantation and 1 year after implantation. The investigators record the time it takes to place 9 sticks in openings and back on the plate again.
Motoric functioning - muscle strength as part of neurological examinationstudy start until 1 year after implantation of last patientThe investigators perform neurological examination during each outpatient clinic visit. We test muscle strength and scale that with the Medical Research Council Scale (MRC) (0-5: no contraction - normal strength).
Quality of life questionnairestudy start until 1 year after implantation of last patientThe patient fills in the Assessment of Quality of Life (AQoL-8D). Scale ranges from 35-175 (high - low quality of life).
Participation abilities - Utrecht´s Scale for Evaluation of Rehabilitation (USER)- Participation questionnairestudy start until 1 year after implantation of last patientThe patient fills in the USER-participation questionnaire. Score ranges from 0-500 (low - good participation)
Complex functional abilities - Action Research Arm Test (ARAT)study start until 1 year after implantation of last patientThe investigators use the ARAT before implantation and 1 year after implantation. Scale ranges from 0-57 points (bad - normal performance).
Motoric functioning - coordination as part of neurological examinationstudy start until 1 year after implantation of last patientThe investigators perform neurological examination during each outpatient clinic visit. Coordination is rated as normal or abnormal.

Countries

Netherlands

Contacts

Primary ContactFrans Leijten, MD, PhD
F.S.S.leijten@umcutrecht.nl+31 88 75 579 83
Backup ContactNick Ramsey, PhD
N.F.Ramsey@umcutrecht.nl+31 88 755 6862