Heart Failure, Diastolic (HFpEF)
Conditions
Brief summary
In a randomized, sham-controlled crossover trial the investigators will test whether supplemental oxygen given during cardiopulmonary exercise testing will improve exercise performance and physiological parameters in patients with heart failure with preserved ejection fraction.
Interventions
Oxygen application Supplemental oxygen via mask
Room air will be applied via mask
Sponsors
Study design
Eligibility
Inclusion criteria
* HFpEF, stable medication for at least 4 weeks.
Exclusion criteria
* instable status, pregnancy, clinically relevant concomitant diseases, inability to follow the study procedures
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Work Rate (Watt) | 1 day | Maximal Work Rate (Watt max) measured during cardiopulmonary exercise test oxygen vs. room air |
| Endurance Time (s) | 1 day | Endurance (s) with 75% Wmax measured during cardiopulmonary exercise test oxygen vs. room air |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Changes in arterial blood parameters (pH) | 1 day | measured during cardiopulmonary exercise test oxygen vs. room air |
| Changes in arterial blood parameters (PaO2) | 1 day | measured during cardiopulmonary exercise test oxygen vs. room air |
| Changes in arterial blood parameters (PaCO2) | 1 day | measured during cardiopulmonary exercise test oxygen vs. room air |
| Peak Oxygen uptake (VO2 max) | 1 day | measured during cardiopulmonary exercise test oxygen vs. room air |
| Changes in arterial blood parameters (Bicarbonate) | 1 day | measured during cardiopulmonary exercise test oxygen vs. room air |
| muscle tissue oxygen | 1 day | Oxygen Saturation in the muscle measured with near-infrared spectroscopy oxygen vs. room air |
| cerebral tissue oxygen | 1 day | Oxygen Saturation in the brain measured with near-infrared spectroscopy oxygen vs. room air |
| Changes in arterial blood parameters (Lactat) | 1 day | measured during cardiopulmonary exercise test oxygen vs. room air |
| Respiratory Exchange Ratio (RER) | 1 day | measured during cardiopulmonary exercise test oxygen vs. room air |
Countries
Switzerland