Evaluation Study of HCV RDTs in Fresh Samples

Prospective Diagnostic Accuracy Study of Rapid Diagnostic Tests (RDTs) Detecting Antibodies Against Hepatitis C Virus (HCV) in Freshly Collected Whole Blood, Plasma and Serum

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04139941
Enrollment
1540
Registered
2019-10-25
Start date
2019-07-31
Completion date
2020-03-31
Last updated
2020-07-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hepatitis C Virus Infection

Brief summary

This study evaluates the sensitivity and specificity performance of three Hepatitis C Virus (HCV) rapid diagnostic tests (RDTs) in freshly collected fingerstick whole blood, as well as serum and plasma (Premier Medical Corporation First Response HCV RDT; Beijing Wantai HCV RDT; AccessBio Care Start HCV under development). Performance is compared to the SD Bioline HCV RDT, as well as a composite reference standard, consisting of two enzyme Immunoassay and a line immunoassay.

Detailed description

Hepatitis C virus (HCV) infection is a major public health burden, with an estimated 71 million patients being infected globally. If undiagnosed, HCV infection can lead to severe liver damage, including hepatocellular carcinoma (HCC). The World Health Organization (WHO) recently set a target to eliminate HCV by 2030. The first critical step in reaching this target is to accurately identify people infected with HCV. Globally, significant gaps remain in diagnosis of HCV, with four out of five people infected still unaware of their status, largely due to lack of access to testing services. In resource-limited settings (RLS), laboratory-based testing remains a mainstay for HCV screening and confirmatory testing. Such laboratory-based assays rely on transportation of temperature-sensitive samples from clinic sites to centralized laboratories, high-tech equipment and highly skilled laboratory technicians, limiting the scope of access to testing and resulting in long turn-around times for results. In recent years, new technologies have been developed to decentralize HCV screening and confirmatory testing using point-of-care (POC) assays to overcome these barriers and improve patient outcomes. Rapid diagnostic tests (RDT) for screening for HCV are affordable, accurate, easy to use by healthcare workers, and robust in field settings. Although a number of HCV RDTs are on the market, currently only two have received WHO pre-qualification (PQ) status, demonstrating their accuracy and reliability for use in the field in RLS. Data on a number of other RDTs indicate their suitability for use. More data is needed, however, in field settings for these HCV RDTs, to demonstrate their accuracy and quality in end-user studies and to provide evidence for WHO PQ approval. Based on the results of a recent FIND laboratory evaluation assessing the performance of 13 HCV RDTs using archived plasma samples, we have selected three candidate HCV RDTs (study RDTs) for further evaluation in field settings (e.g. primary healthcare facilities). The performance of these RDTs measured in frozen plasma specimens indicated that they have a high potential to meet WHO PQ performance criteria in freshly collected samples. In addition, the manufacturers each demonstrate evidence of engagement to pursue both CE-mark status and the WHO PQ process, showing commitment to delivering quality-assured tests to the market. The data generated during this study will be used to inform national and international stakeholders on HCV RDT performance in field settings and shared with manufacturers to support the evidence package for WHO PQ and/or CE-marking.

Interventions

DIAGNOSTIC_TESTTest for HCV antibodies with an RDT

Fingerstick whole blood, plasma and serum of each participant is tested with three investigational HCV RDTs and one reference HCV RDT. Plasma is also used for testing with the composite reference standard, HCV viral load and genotyping. All participants are also tested for HIV with an HIV RDT.

Sponsors

Institute of Tropical Medicine, Belgium
CollaboratorOTHER
Foundation for Innovative New Diagnostics, Switzerland
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum

Inclusion criteria

* ≥ 18 years of age * Known or unknown HCV serology * No history of past or present HCV treatment * Willing to undergo the information and consenting procedure and subsequently have enough time to participate in the study * Willing to provide 13 ml venepuncture blood sample and a minimum of four whole blood fingerstick samples * Willing to perform an HIV test * Individuals can already be registered at the local site or register for the first time when enrolling in the study

Exclusion criteria

* Participants not able to consent themselves (incapable)

Design outcomes

Primary

MeasureTime frameDescription
Sensitivity and specificity of HCV RDTs compared to a composite reference standardthrough study completion, on average 1 year1.1 Point estimates of sensitivity, specificity, positive and negative predicative values (with 95% confidence intervals) and Cohen's Kappa Coefficient (κ) of inter-rater agreement for each RDT, using a combination of two EIAs (Enzyme Immunoassay) and an LIA (Line immunoassay) as a composite reference standard for the detection of anti-HCV antibodies in fingerstick whole blood, EDTA plasma and serum.

Secondary

MeasureTime frameDescription
Sensitivity and specificity of HCV RDTs compared to an HCV RDT pre-qualified by WHO as reference standardthrough study completion, on average 1 year2.1 Point estimates of sensitivity, specificity, positive and negative predicative values (with 95% confidence intervals) and Cohen's Kappa Coefficient (κ) of inter-rater agreement for each RDT, using the WHO-PQ RDT as reference standard for the detection of anti-HCV antibodies in fingerstick whole blood, EDTA plasma and serum
Operational characteristicsthrough study completion, on average 1 year2.2 Operational characteristics and usability of study RDTs: \- Rate of invalid test results /errors: Percentage of invalid test results/errors by RDT, site and error type

Countries

Cambodia, Georgia

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026