Skip to content

Impact of Change of Head and Neck Position on Cricothyroid Membrane Localization and Membrane Height in Parturient Patients

Impact of Change of Head and Neck Position on Cricothyroid Membrane Localization and Membrane Height in Parturient Patients: an Observational Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04138121
Enrollment
50
Registered
2019-10-24
Start date
2019-11-04
Completion date
2019-12-20
Last updated
2020-09-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Airway Complication of Anesthesia

Keywords

cricothyroid membrane, pregnancy, ultrasound

Brief summary

The cricothyroid membrane acts a route through which the upper airway can be accessed in order to provide oxygen and ventilation to patients. The need to provide oxygen and ventilation to patients is essential particularly under general anesthesia, where patients may lose the ability to breathe for themselves. Access through this membrane to provide oxygen and ventilation is critical in emergency situations where other traditional means to access the airway (e.g through endotracheal ventilation, supraglottic airway devices or face mask ventilation) have failed. It is known that due to the physiological changes of pregnancy, the upper airway of the body undergoes changes that can make accessing the airway through traditional means more difficult. Ultrasound is becoming increasingly popular due to its ability to identify the cricothyroid membrane, to improve success in accessing the airway through the cricothyroid membrane. Studies to date in non pregnant adults have shown that alterations in the head and neck position can alter the position and size of the cricothyroid membrane. No study to date however has looked at how changing the position of the head and neck effects the position and size of the cricothyroid membrane in pregnant patients. It is important to study these changes in the pregnant population, given the physiological changes of pregnancy that make accessing the airway through traditional methods more difficult in non pregnant patients. The investigators hypothesize that in pregnant patients in the third trimester, that changing the head from the neutral to maximally extended neck position will alter the position of the cricothyroid membrane in relation to anatomical skin markings between positions. The investigators also hypothesize that in pregnant patients in the third trimester that changing the head from the neutral to maximally extended neck position will increase the size of the cricothyroid membrane. The investigatorsalso aim to determine at what position in the neck a theoretical standardized incision will allow access to the cricothyroid membrane.

Detailed description

This is an observational study. Participants: 1. One of two anesthesiologists trained in cricothyroid membrane ultrasound scanning technique in pregnant population (study investigators) 2. Subjects to be assessed: pregnant patients in their third trimester on the labor and delivery floor comfortable enough to take part in the study Two anesthesiologists will undergo ultrasound imaging training by an expert staff anesthesiologist whom is already trained in the procedure. As per previous published evidence on this, the investigator will need to correctly identify the location of cricothyroid membrane and its height in 15 volunteers. This will constitute the standardized training component of the study. Upon admission to the Labor and Delivery floor, women will be further explained the protocol and asked to sign the consent form. Then, they will have the cricothyroid membrane assessed, as per description above, and quantitative assessment will be performed. Firstly, quantitative assessment of the height of the cricothyroid membrane will be performed in the supine position (with left uterine displacement) with the neck in the neutral position. The central point of the cricothyroid membrane will be marked using a removable skin ink marker. The patient will then be asked to fully their neck. The change in distance of the midpoint of the cricothyroid membrane from the neutral head and neck position to fully extended positioned will be performed, as will the change in height of the cricothyroid membrane between the two positions. Quantitative assessment for change in central cricothyroid membrane distance will be done with measuring central points marked on the patients neck with skin marker ink. Quantitative assessment of change in cricoid thyroid membrane will be conducted using caliper measuring software build into the ultrasound machinery. Finally, the investigators will establish the starting distance above the sternal notch over which a theoretical 8cm incision in the neck which will overlie the cricothyroid membrane. This will be done by measuring the distance above the sternal notch with a surgical measuring ruler.

Interventions

DEVICEUltrasound

Ultrasound scan of the cricothyroid membrane

Sponsors

Samuel Lunenfeld Research Institute, Mount Sinai Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Pregnant patients in third trimester (\>28/40 weeks) * Ability to understand the rationale of the study assessments and to provide signed consent.

Exclusion criteria

* Neck arthritis * Cervical stenosis * Known cervical degenerative disc disease * Rheumatoid Arthritis * Any restriction of neck movement * Upper limb neurology * Patient refusal * Non pregnant patients * Pregnant patients less than 28 weeks pregnant

Design outcomes

Primary

MeasureTime frameDescription
Cricothyroid membrane position change30 minutesTo measure the distance the center of the cricothyroid membrane changes position on ultrasound between neutral and maximal neck extension in third trimester patients.

Secondary

MeasureTime frameDescription
Cricothyroid membrane size change30 minutesTo measure the distance that the size of the cricothyroid membrane changes position on ultrasound between neutral and maximal neck extension in third trimester patients.
Distance above sternal notch30 minutesThe starting distance above the sternal notch in the neck over which an 8cm incision in the neck should overlie the cricothyroid membrane

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026