Skip to content

Cardiac Function Non-Invasive Monitoring System Evaluation Trial

Cardiac Function Monitoring System Evaluation

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04131725
Enrollment
275
Registered
2019-10-18
Start date
2020-11-09
Completion date
2023-04-30
Last updated
2023-11-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Disease

Brief summary

Non-significant risk device study to conduct evaluation of the performance of new device for monitoring of cardiac function (based on previous iterations 510(k) 173156)

Detailed description

Non-significant risk device study to conduct evaluation of the performance of new device for monitoring of cardiac function (based on previous iterations 510(k) 173156)

Interventions

Device: Cardiac Performance System Participants will be asked to wear the Cardiac Performance System, a non-invasive sensor device on their upper abdomen. The Cardiac Performance System monitoring device will continuously monitor cardiac function. The device will be worn at the time when Pulmonary Artery Catheter procedures are conducted.

Sponsors

University of Pittsburgh Medical Center
CollaboratorOTHER
Sensydia Corporation
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Adults of age 18 or older

Exclusion criteria

* Subjects with wounds or surgical incisions at the site of sensor placement

Design outcomes

Primary

MeasureTime frameDescription
Cardiac Performance System electronic data for Cardiac Output60 minutes during Pulmonary Artery Catheter procedureCardiac function metric measurement including Cardiac Output to report in L/m.
Cardiac Performance System electronic data for Pulmonary Artery Pressure60 minutes during Pulmonary Artery Catheter procedureCardiac function metric measurement including Pulmonary Artery Pressure to report in mmHg.
Cardiac Performance System electronic data for Pulmonary Artery Wedge Pressure60 minutes during Pulmonary Artery Catheter procedureCardiac function metric measurement including Pulmonary Artery Wedge Pressure to report in mmHg.
Pulmonary Artery Catheter electronic data for Cardiac Output60 minutes during Pulmonary Artery Catheter procedureCardiac function metric measurement including Cardiac Output to report in L/m.
Pulmonary Artery Catheter electronic data for Pulmonary Artery Pressure60 minutes during Pulmonary Artery Catheter procedureCardiac function metric measurement including Pulmonary Artery Pressure to report in mmHg.
Pulmonary Artery Catheter electronic data for Pulmonary Artery Wedge Pressure60 minutes during Pulmonary Artery Catheter procedureCardiac function metric measurement including Pulmonary Artery Wedge Pressure to report in mmHg.
Echocardiography electronic data for Ejection Fraction15 minutes at a time prior to or after Pulmonary Artery Catheter procedureCardiac function measurement including left ventricle ejection fraction to report in percentage.