Esophageal Varices in Cirrhosis of the Liver
Conditions
Brief summary
This study is intended to include 20 patients with esophageal varices caused by liver cirrhosis who were admitted to the first affiliated hospital of nanjing medical university from May 2019, and randomly select 8 patients with gastric polyps as the control group.General clinical data, imaging data, endoscopic data and laboratory indicators were collected.Electrogastrogram (EGG) and Heart Rate Variability (HRV) were performed before and 24 hours after operation in patients with cirrhotic esophageal varices, and the dyspepsia scale was filled out.Electrogastrogram (EGG) and cardiac variability (HRV) were performed in patients with gastric polyps 24 hours before and after surgery, and the dyspepsia scale was filled.EGG uses the surface electrode to record gastric myoelectric activity, and evaluates the patient's gastric rhythm by normal slow wave ratio, overspeed ratio, overslow ratio, and rhythm disorder ratio.The HRV evaluates the balance state of the patient's autonomic nervous system with High Frequency (HF)/Low Frequency (LF).SPSS software was used for paired sample analysis of experimental results.
Interventions
Heart Rate Variability
Heart Rate Variability
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients over 18 years old with cirrhosis of esophageal varices who underwent endoscopic ligation * Signed informed consent
Exclusion criteria
* Hemorrhage in the digestive tract, unstable vital signs * Hepatic encephalopathy * Unwilling to cooperate with the examiner * Skin allergies
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Gastric Slow Wave of patients before the surgery, Change from Baseline Gastric Slow Wave 1 day after the surgery ,Change from Baseline Gastric Slow Wave 5 days after the surgery | before the surgery, 1 day after the surgery, and 5 days after surgery | EGG evaluate patient's gastric electrical rhythm by normal slow wave ratio, overspeed ratio, overslow ratio, and rhythm disorder ratio Evaluating patient's gastric electrical rhythm by normal slow wave ratio, overspeed ratio, overslow ratio, and rhythm disorder ratio Evaluating patient's gastric electrical rhythm by normal slow wave ratio, overspeed ratio, overslow ratio, and rhythm disorder ratio Evaluating patient's gastric electrical rhythm by normal slow wave ratio, overspeed ratio, overslow ratio, and rhythm disorder ratio |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| LF/HF of patients before the surgery, Change from Baseline LF/HF 1 day after the surgery ,Change from Baseline LF/HF 5 days after the surgery | before the surgery, 1 day afterthe surgery, and 5 days after surgery | HRV assesses the balance of the patient's autonomic nervous system with high frequency (HF) / low frequency (LF) |
Countries
China