Skip to content

Effects of Dry Needling, Static Stretching and IASTM in People With Hamstring Muscle Shortness

Comparison of the Effects of Dry Needling, Static Stretching and Instrument Assisted Soft Tissue Mobilization Techniques on Function, Performance and Muscle Structure in People With Hamstring Muscle Shortness

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04118231
Enrollment
60
Registered
2019-10-08
Start date
2019-10-01
Completion date
2021-06-01
Last updated
2022-01-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hamstring Muscle Shortness and Elastographic Examination

Keywords

Hamstring Shortness, Dry Needling, Elastography

Brief summary

The aim of this study was to investigate the effects of dry needling, static stretching and instrument assisted soft tissue mobilization on joint range of motion, performance and muscle structure in individuals with Hamstring muscle shortness and to examine the changes in soft tissue before and after application with the help of ultrasound elastography.

Detailed description

The study was randomly divided into 3 groups. Group 1: Hamstring muscle group of patients for 5 minutes Instrument Assisted Soft Tissue Mobilization made of stainless steel instruments used by soft tissue mobilization by the therapist. In order to reduce friction and increase lubricity before application; If there is an unexpected erythema, edema or other unexpected side effects, the application will be stopped immediately. 2.Group: In the Hamstring muscle group of the patients, the acupuncture needles, which are made of stainless steel, sterile and disposable, will be applied under the supervision of an expert doctor for 30-45 seconds. In case of unexpected side effects, the application will be terminated. Group 3: Patients' Hamstring muscle group under the supervision of the physiotherapist for a total of 5 minutes; A total of 10 repetitions of static tension will be applied for 30 seconds. Before starting the study, anthropometric measurements, vertical and horizontal jump amounts of all participants will be measured before the application. Digital inclinometer will be used to determine the range of motion of the joint. Measurements will be made before and after the first application and the last measurement will be made 3 days after the end of 12 sessions. In addition, soft tissue changes in the hamstring muscle of the participants will be evaluated by US elastography before and at the end of the 12th session.

Interventions

OTHERDry needling

Group 1: Dry needling Group 2: static stretching Group 3: IASTM

Sponsors

Gazi University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

1. 18-35 age range 2. Volunteer to participate in the study 3. Not having a diagnosed condition

Exclusion criteria

1. Having any diagnosed discomfort 2. Being pregnant 3. Previously undergo surgery on the lower extremity 4. Physical therapy and rehabilitation of lower extremity in the last 6 months

Design outcomes

Primary

MeasureTime frameDescription
Muscle stiffness4 weeksMuscle stiffness will be evaluated by an expert radiologist using ultrasound elastography.
Range of motion4 weeksThe amount of hip flexion will be measured using a digital inclinometer.
Muscle Strength4 weeksMuscle strength will be assessed in newton using a digital hand dinanometer.
Vertical jump4 weeksThe amount of vertical jump will be calculated from the value of cm by the tape measure fixed to the wall.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026