Skip to content

New Imaging Biomarkers for Muscular Diseases - Multispectral Optoacoustic Imaging in Spinal Muscular Atrophy

New Imaging Biomarkers for Muscular Diseases - Multispectral Optoacoustic Imaging in Spinal Muscular Atrophy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04115475
Acronym
MSOT_SMA
Enrollment
20
Registered
2019-10-04
Start date
2019-11-07
Completion date
2020-01-30
Last updated
2020-11-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Muscular Diseases, Spinal Muscular Atrophy

Keywords

Muscular Diseases, Spinal Muscular Atrophy (SMA), MSOT

Brief summary

This study aims to refine the capability of MSOT to characterise muscle tissue and to determine non-invasive, quantitative biomarkers for the disease assessment in patients with spinal muscular atrophy (SMA) using Multispectral Optoacoustic Tomography (MSOT).

Detailed description

SMA is an autosomal-recessive disorder, characterized by progressive muscle weakness and atrophy with an incidence of 1/10,000. The condition is caused by a homozygous deletion or mutation in the survival motor neuron 1 (SMN1), resulting in reduced expression of the survival motor neuron (SMN) protein. This leads to the degeneration of motor neurons in the spinal cord and brain stem. A nearby related gene, survival motor neuron 2 (SMN2), could partially compensate the loss of SMN1. Individuals with a higher copy number of SMN2 do in general have a milder phenotype. New therapeutic approaches, e.g. nusinersen (spinraza©), an antisense oligonucleotide medication that modulates pre-messenger RNA splicing of the survival motor neuron 2 (SMN2) gene, are promising to help the formerly incurable children. However, most clinical trials lack primary outcomes other than clinical testing. At the moment there are no prospective, quantitative biomarkers available to detect muscle atrophy at an early age, and to follow up disease progression. As a new imaging modality, optoacoustic imaging (OAI) combines benefits of optical (high contrast) and acoustic (high resolution) imaging. Multispectral optoacoustic tomography (MSOT) is therefore capable of visualizing the distribution of endogenous absorbers by initiating laser-induced thermoelastic expansion and detection of resulting pressure waves. This imaging technique enables the label-free detection and quantification of different endogenous chromophores, such as melanin, hemoglobin, deoxyhemoglobin and lipids. Previously, it was demonstrated that MSOT is capable to monitor disease severity in Crohn's disease by detecting different signal levels of hemoglobin as markers of intestinal inflammatory activity. In this study we want to refine the capability of MSOT to characterize muscle tissue and to determine a non-invasive, quantitative biomarker for the disease assessment in SMA patients from birth using MSOT.

Interventions

Non-invasive transcutaneous imaging of subcellular muscle components

Sponsors

University of Erlangen-Nürnberg Medical School
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

* genetically proven SMA

Exclusion criteria

* Pregnancy * Tattoo on skin to be examined * For healthy volunteers only: suspected muscular disease/myopathia

Design outcomes

Primary

MeasureTime frameDescription
Spectral profile of muscle tissueSingle time point (1 day)Spectral profile of muscle tissue determined by multispectral optoacoustic tomography (MSOT) of patients with spinal muscular atrophy compared to healthy volunteers units: arbitrary units (a.u.)

Secondary

MeasureTime frameDescription
Muscular collagen contentSingle time point (1 day)Quantitative collagen signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA compared to healthy control Units: arbitrary units (a.u.)
Muscular myo-/hemoglobin contentSingle time point (1 day)Quantitative myo-/hemoglobin signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA compared to healthy control Units: arbitrary units (a.u.)
Muscular de-/oxygenated myo-/hemoglobin contentSingle time point (1 day)Quantitative de-/oxygenated myo-/hemoglobin signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA compared to healthy control Units: arbitrary units (a.u.)
Correlation of lipid signal with clinical data (age/disease duration)Single time point (1 day)Quantitative lipid signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual clinical data (disease duration/age (in month))
Correlation of collagen signal with clinical data (age/disease duration)Single time point (1 day)Quantitative collagen signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual clinical data (disease duration/age (in month))
Correlation of myo-/hemoglobin signal with clinical data (age/disease duration)Single time point (1 day)Quantitative myo-/hemoglobin signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual clinical data (disease duration/age (in month))
Muscular lipid contentSingle time point (1 day)Quantitative lipid signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA compared to healthy control Units: arbitrary units (a.u.)
Correlation of lipid signal with physical assessment (HINE/HFMSE/CHOP INTEND/ULM)Single time point (1 day)Quantitative lipid signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual physical assessment (HINE/HFMSE/CHOP INTEND/ULM)
Correlation of collagen signal with physical assessment (HINE/HFMSE/CHOP INTEND/ULM)Single time point (1 day)Quantitative collagen signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual physical assessment (HINE/HFMSE/CHOP INTEND/ULM)
Correlation of myo-/hemoglobin signal with physical assessment (HINE/HFMSE/CHOP INTEND/ULM)Single time point (1 day)Quantitative myo-/hemoglobin signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual physical assessment (HINE/HFMSE/CHOP INTEND/ULM)
Correlation of de-/oxygenated myo-/hemoglobin signal with physical assessment (HINE/HFMSE/CHOP INTEND/ULM)Single time point (1 day)Quantitative de-/oxygenated myo-/hemoglobin signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual physical assessment (HINE/HFMSE/CHOP INTEND/ULM)
Side differences of MSOT signalsSingle time point (1 day)Quantitative collagen signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA compared between sides Units: arbitrary units (a.u.)
Correlation of RUCT and B-Mode UltrasoundSingle time point (1 day)Quantitative grey scale signal derived by reflection mode ultrasound computed tomography (RUCT) correlated with grey scale B-Mode Ultrasound
Correlation of de-/oxygenated myo-/hemoglobin signal with clinical data (age/disease duration)Single time point (1 day)Quantitative de-/oxygenated myo-/hemoglobin signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with SMA correlated with individual clinical data (disease duration/age (in month))

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 8, 2026