Skip to content

Closed-loop Vasopressor Infusion Using Continuous Noninvasive Blood Pressure Monitoring

Feasibility of Computer-assisted Vasopressor Infusion Using Continuous Noninvasive Blood Pressure Monitoring in High-risk Patients Undergoing Renal Transplant Surgery

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04111055
Enrollment
3
Registered
2019-10-01
Start date
2018-06-15
Completion date
2018-07-20
Last updated
2019-11-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hemodynamic (MAP) Stability

Brief summary

Intraoperative hypotension and blood pressure variability are associated with postoperative complications in surgical patients. The investigators have developed a closed-loop vasopressor (CLV) controller that titrates norepinephrine to correct hypotension. After having tested the system in a small cohort series of patients undergoing major surgeries, the investigators aimed to test the feasibility of the CLV controller guided noninvasively and continuously with the ClearSight system (Edwards Lifesciences, USA) in three high risk patients undergoing renal transplant surgery

Detailed description

Intraoperative hypotension is frequent in patients undergoing surgery and can negatively impact organ perfusion. The investigators have developed a closed-loop vasopressor (CLV) controller to more efficiently correct hypotension. The investigators tested it extensively in preclinical studies and recently demonstrated its feasibility and excellent performance metrics in a short series of high-risk patients undergoing major surgical procedures. In these studies, the controller was linked to a minimally-invasive advanced hemodynamic monitoring device utilizing an arterial line which then controlled a vasopressor infusion. However, the vast majority of patients who undergo surgery do not require an arterial line but should still benefit from rapid corrections of hypotensive episodes that are less rapidly detected via an intermittent non-invasive blood pressure cuff. Fortunately, completely noninvasive technology now allows us to continuously monitor blood pressure and therefore extend the use of our closed-loop vasopressor system to patients in whom an arterial catheter would not typically be placed. Patients undergoing renal transplant surgeries are the ideal patient population. The investigators aimed to test the feasibility of guiding our CLV controller with a continuous noninvasive blood pressure monitoring device (ClearSight system, Edwards Lifesciences, Irvine, CA, USA) in three patients (case series)

Interventions

the CLV system will correct hypotension by automated adjustment of norepinephrine.

Sponsors

University of California, Los Angeles
CollaboratorOTHER
University of California, Irvine
CollaboratorOTHER
Erasme University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Single prospective pilot study

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

1. Adult high risk patients undergoing renal transplant surgery 2. Patients equipped with a clearsight advanced hemodynamic monitoring system

Exclusion criteria

1. Atrial fibrillation 2. No consent obtained from the patient. 3. Ejection fraction \< 30%

Design outcomes

Primary

MeasureTime frameDescription
Percentage of case time in hypotensionduring surgery% of case time without hypotension. MAP of at least 5mmHg below the chosen CLV target

Secondary

MeasureTime frameDescription
Percentage of active treatment time spent in a hypertensive stateduring surgeryPercentage of active treatment time spent in a hypertensive state, defined as a MAP \>5mmHg above the chosen target MAP with an active norepinephrine infusion
Amount of vasopressor usedduring surgeryAmount of vasopressor administered to the patient
Incidence of acute kidney injury30 days postsurgeryIncidence of acute kidney injury defined with the KDIGO classification

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026