Characterization of Left Atrial Substrate by Comparison of Bipolar Voltage Maps With Standard Focal 4.5 mm Tip Electrode, 1 mm Ring Electrode, and Microelectrode Catheters Using InTEllaMap Orion and IntellaNav MIFI O

Characterization of Left Atrial Substrate by Comparison of Bipolar Voltage Maps With Standard Focal 4.5 mm Tip Electrode, 1 mm Ring Electrode, and Microelectrode Catheters Using InTEllaMap Orion and IntellaNav MIFI O

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04095559
Acronym
CHAZESubstrate
Enrollment
25
Registered
2019-09-19
Start date
2019-12-05
Completion date
2021-05-31
Last updated
2021-11-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation (AF)

Keywords

left atrial (LA) substrate-based ablation, focal ablation catheter, bipolar voltage amplitude, micro-electrode catheter, IntellaMap Orion, IntellaNav MIFI OI, bipolar voltage maps, irrigated-tip ablation catheter, ring-electrode circular mapping catheter, microelectrode multipolar catheter

Brief summary

This study is to investigate the correlation and to obtain the coefficient of correlation between the global and local bipolar signals (voltage maps) of the LA in sinus rhythm using a focal 4.5 mm irrigated-tip ablation catheter (in combination with microelectrodes), a ring-electrode circular mapping catheter and a microelectrode multipolar catheter in combination with the Rhythmia system.

Detailed description

Current hypothesis of the mechanism of atrial fibrillation (AF) is a combination of local firing mainly triggered from the pulmonary veins and atrial substrate due to atrial remodelling sustaining AF. Whereas for paroxysmal AF, pulmonary vein isolation (PVI) is still the mainstay of interventional treatment, a left atrial (LA) substrate-based ablation especially in patients with persistent or long-standing persistent AF may be reasonable to improve freedom from AF. In addition, even in patients with paroxysmal AF, substrate-based ablation strategies have been shown to improve outcome. Substrate characterization of the LA is currently performed using the focal ablation catheter with a 3.5mm irrigated tip catheter with a 2 mm interelectrode spacing, a circular (Lasso) or spider like diagnostic (Pentaray) catheter with 1 mm size of the ring electrodes and 2 mm to 4 mm interelectrode spacing. Consequently, the cut-off values to delineate healthy tissue from diseased substrate are defined based on these measures. Since the electrode size and distance between the electrodes determines the bipolar voltage amplitude and morphology (beside their orientation with regard to the propagation wavefront), differences in bipolar voltage values must be expected between different catheter types and especially for the novel micro-electrode catheters IntellaMap Orion and IntellaNav MIFI OI. With the knowledge of the relationship between the bipolar voltage maps created with the different catheter types, information/knowledge from one study obtained with a specific catheter can be transferred to patients treated with the other catheter types. This study is to investigate the correlation and to obtain the coefficient of correlation between the global and local bipolar signals (voltage maps) of the LA in sinus rhythm using a focal 4.5 mm irrigated-tip ablation catheter (in combination with microelectrodes), a ring-electrode circular mapping catheter and a microelectrode multipolar catheter in combination with the Rhythmia system.

Interventions

DIAGNOSTIC_TESTmultipolar mapping catheter

mapping of the left atrium will be performed in sinus rhythm using the IntellaMap Orion multipolar mapping catheter (Boston Scientific).

DIAGNOSTIC_TESTmultielectrode circular catheter

mapping of the left atrium will be performed using the multielectrode circular catheter (Lasso, spacing 2-6-2 mm, Biosense Webster)

mapping of the left atrium will be performed using the irrigated ablation catheter (IntellaNav Mifi OI)

Sponsors

Boston Scientific Corporation
CollaboratorINDUSTRY
University Hospital, Basel, Switzerland
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Documented atrial fibrillation * First or repeat catheter ablation

Exclusion criteria

* Previous heart surgery (high probability for atypical atrial tachycardia and non PV triggers for AF) * Congenital heart disease (corrected or uncorrected) * Severe uncorrected valvular heart disease * Not willing or qualified for Magnetic Resonance Imaging of the heart * Unable to provide informed consent * Pregnancy (Pregnancy test will be performed before study participation) * Patients with pacemaker or intracardiac defibrillator implanted

Design outcomes

Primary

MeasureTime frameDescription
Global bipolar and unipolar signal measured in millivolt (mV)single time point assessment at baselineGlobal bipolar and unipolar signal for the different types of catheters measured in mV
Local bipolar and unipolar signal measured in mVsingle time point assessment at baselineLocal bipolar and unipolar signal for the different types of catheters measured in mV

Secondary

MeasureTime frameDescription
Differences of bipolar voltage characteristics between nearfield and farfield signals: amplitude (mV)single time point assessment at baselineDifferences of bipolar voltage characteristics between nearfield and farfield signals: amplitude (mV)
Global fibrosis content and distribution from LGE-MRI measured in [%].single time point assessment at baselineGlobal fibrosis content and distribution from LGE-MRI measured in \[%\].
Differences of bipolar voltage characteristics between nearfield and farfield signals: Duration in milliseconds (ms)single time point assessment at baselineDifferences of bipolar voltage characteristics between nearfield and farfield signals: duration (ms)
Differences of bipolar voltage characteristics between nearfield and farfield signals: frequency in Hertz (Hz)single time point assessment at baselineDifferences of bipolar voltage characteristics between nearfield and farfield signals: frequency (Hz)
Local fibrosis content and distribution from Late-gadolinium enhanced Magnetic Resonance Imaging (LGE-MRI) measured in [%].single time point assessment at baselineLocal fibrosis content and distribution from LGE-MRI measured in \[%\].